Photoelectric proximity switch IRS/IRN/IRD-**I-OFX/OVA(-OP)
IRD-**I-OFX/OVA-OP
IECEx BVS 14.0108X
0158
IECEx markings
II 2(1)G
Ex d [op is Ga] IIC T6 Gb
II 2(1)D
Ex tb [op is Da] IIIB T100°C Db IP67
Technical Data
Range (on white paper A4, 80g)
Type of Ex protection, Gas, according to 2014/34/EU
Type of Ex protection, Dust, according to 2014/34/EU
For use in Ex Zones
Maximum radiant intensity
Maximum radiant power
Light
source
Optical angle (at nominal range)
Response time
Power up delay time
Supply voltage
Absolute maximum supply voltage
Current consumption
Maximum power dissipation
Output
Input, only
types IR*-**I-OFI/OVI(-OP) (Disable Input)
Housing
Enclosure rating, according to EN 60529
Working temperature range
T
amb
Storage temperature range
Shock and vibrating resistance
Pollution degree, according to EN 60664-1:2007
Device designation, according to EN 60947-5-2
Electrical connection cable
Electrical connection cable, types
Electrical connection cable, types
Socket for types
IRS/IRN-**I-***-OP-S099
Accessories, all types
Accessories, types IRN/IRD-**I-***-OP(-S***)
Accessories, only type IRN-**I-***-OP-S099
Accessories,
optional for the types IR*-(-OP)-S099
Accessories, not included, only IRS-**I-O**-S125
Options
- Cable length:
- IR*-**I-OVA(-OP):
- IR*-**I-OFI(-OP):
- IR*-**I-OVI(-OP):
- IRD-04I-***-OP-S095:
- IRD-04I-***-OP-S097:
- IRS/IRN-**I(-OP)-S099:
- IRS-02I/04I-***-S125:
- IR*-**I-***(-OP)-S268:
- IR*-02I-***(-OP)-S269:
- IRS/IRN-02I-***(-OP)-S270:
- IR*-02I-***(-OP)-S271:
- IRD-10I-OFP-OP:
Function at standard connection
of the supply voltage:
Wire No.
+24VDC
1
0V
2
Output
3
Pollution indication output
4
Disable input (only DI types)
5
PE
yellow-green
Cable shield
white
(Devices S099: Only pollution output or disable input possible)
Function on reversed polarity of the
supply voltage:
Wire No.
+24VDC
2
0V
1
Output
3
Pollution indication output
4
Disable input (only DI types)
5
PE
yellow-green
Cable shield
white
(Devices S099: Only pollution output or disable input possible)
Devices with pollution
indication output "VA".
Types:
IR*-**I-OVA/OVI(-OP).
Sensor
LED indication
and output function:
Original operating manual:
Housing M30
• Also for using with certificated fibre optics
• IRD: ATEX and IECEx certificated
• Types IRD: For use in Ex Zones (0),1, 2, (20), 21, 22
optical radiation can operate into Ex Zones 0, 20
• Types IRN; For use in Ex Zones (1), 2, (21), 22
optical radiation can operate into Ex Zones 1, 21
• Robust sensor for industrial applications
Type
IRS-**I-OFX/OVA
NONE
NONE
Not for Ex zones
NOT LIMITED
NOT LIMITED
Vibration: 30g over 20Hz to 2kHz. Shock:50g for each direction (X, Y, Z)
3+PE x 0.5mm
IR*-**I-OVA/OFI(-OP)
4+PE x 0.5mm
IR*-**I-OVI(-OP)
5+PE x 0.5mm
- 2 nuts M30 (optional 1 clamp on demand)
- 1x
Spare safety screw with packing ring for potentiometer sealing
- 1x
Safety lock device, mount at the cable connection,
connection. (black synthetic device)
- 1x Warning plate
self-sealing, for gluing on the cable connector.
- 1x Protection cap for the sensor socket.
- Single ended cordset, types RKTS 5-298/xx or
- Spare safety screw with packing ring for potentiometer sealing
Up to
100m, on request. Designation: IR*-**I-***(-OP)/K:??m
With additional pollution indication output "VA", only PNP type
With emitter disable input "DI"
With additional pollution indication output "VA" and with emitter disable input "DI"
With additional optic, type AD-4-W 15, cable length: 10m
Response time: 150us, cable length: 5m
Socket M12, Lumberg RSF 5 , 5 pins
Potentiometer with dust proof screwing. (IRS-02I-OFX-S125: Range = 180mm+-5%)
1kHz
switching frequency
10kHz
switching frequency
Socket M12, Lumberg RSF 5 , 5 pins, response time: 500us
With wide optical angle 22°
Output only PNP, function: Output=ON if sensor detects light
Light barrier
with fibre optics
Proximity switch
with fibre optic
Pin-No.
1
3
4
2
2
5
Pin-No.
3
1
4
2
2
5
ca. 120%
100%
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
green
ISO 9001:2008 / ATEX
IRN-**I-OFX/OVA-OP
OFX = output function selectable by polarity of the supply volteage
**I = Range in dm 02I/04I/10I/15I. 0.2m to 1.5m
II 3(2)G Ex nA [op is Gb] IIB T4 Gc
II 3(2)D Ex tc [op is Db] IIIA
T135°C Dc IP67
Zones (1), 2, (21), 22
<=5mW/mm
<=35mW
Infrared 870nm
appr. 10°
5ms (1ms, on request)
500ms
24 VDC +-10%
Um = 30VDC
maximum 60mA
1.68W
Push-Pull, 100mA, short circuit protected
PNP compatible, Ri 10kΩ
M30, yellow brass, type Ms58, nickel plated
IP54
IP67
-20°C up to +50°C
-30°C ... +70°C
4
R3A30AP1
2
, shielded, TPU,
leads numbering marked, length: 3m
2
, shielded, TPU,
leads numbering marked, length: 3m
2
, shielded, TPU,
leads numbering marked, length: 3m
Socket
M12, Lumberg
type RSF, 5 terminals
"Do not open/close when supply voltage
Light barrier
Beam not interrupted
with fibre optics
Proximity switch
with fibre optic
reflection detected, LED=ON
+24VDC
PNP=OFF
R 15Ω
Out
NPN=ON
0V
+24VDC
PNP=ON
R 15Ω
Out
NPN=OFF
0V
distance to object
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9 0 1
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9 0 1
yellow
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9 0 1
1 2 3 4 5 6 7 8 9
IRN-**I-OFX/OVA-OP
ATEX designation:
II 3(2)G Ex nA [op is Gb] IIB T4 Gc
II 3(2)D Ex tc [op is Db] IIIA T135°C Dc IP67
IRD-**I-OFX/OVA-OP
II 2(1)G Ex d [op is Ga] IIC T6 Gb
II 2(1)D Ex tb [op is Da] IIIB
T100°C Db IP67
Zones (0), 1, 2, (20), 21, 22
2
<=5mW/mm
2
<=15mW
IP67
for locking the
connected",
RKWTH 5-298/xx,Lumberg
Beam interrupted
no reflection detected, LED=OFF
+24VDC
PNP=ON
R 15Ω
Out
NPN=OFF
0V
+24VDC
PNP=OFF
R 15Ω
Out
NPN=ON
0V
ON
Pollution indication output VA
OFF
ON
Output
OFF
red
LED indication
Page 1 of 2