  • Page 1 AirSanitizer INSTRUCTION MANUAL...
  • Page 2 Instruction Manual AirSanitizer In addition to the instructions in this guide, subject-specific standards, as well as local, national and international regulations must be observed. The instruction manual is available online, see QR-code beneath. The online version always contains the updated version.
  • Page 3: Table Of Contents

    Instruction Manual AirSanitizer Table of contents Introduction ..........................4 Supplementary instructions to this instruction and operation manual ....... 4 Limitation of liability ......................4 Intended use / foreseeable misuse .................. 4 1.3.1 Intended use ........................4 1.3.2 Foreseeable misuse ......................4 Documentation ........................
  • Page 4 Instruction Manual AirSanitizer 10.1 Declaration of conformity S-Version ................23 10.2 Declaration of conformity M-Version ................24 11 Nameplate ..........................25 11.1 Nameplate S-Version ....................25 11.2 Nameplate M-Version ....................26 Figure index ..........................27 Table index ..........................27 - Original Instructions - V12-20.0...
  • Page 5: Introduction

    ‘AHU’. This instruction manual is part of the AHU and enable the safe and correct use of an AHU from EUROCLIMA. The target group of this instruction manual are all persons who are fa- miliar with transport, assembly, commissioning and installation, operation, maintenance, trouble- shooting and disassembling (see also chapter 2.5 (Staff selection and qualification)).
  • Page 6: Documentation

    Silencer Fan / Potentiometer Motor (inside the AHU) Silencer ON / OFF HEPA filter H 13 switch (EN 1822:2019) Pre-filter ePM 85% (ISO 16890) (rear of the AHU) Micro fuse Air inlet Figure 1: Construction air purifier “AirSanitizer” V12-20.0 5/28...
  • Page 7: Technical Data

    Instruction Manual AirSanitizer 1.5.2 Technical data Information S-Version M-Version Dimensions 2003 x 710 x 405 mm 2307 x 710 x 710 mm (height x width x depth) Weight unpacked Ca. 135 kg Ca. 175 kg Length of cable 3 meter...
  • Page 8: Personal Protective Equipment

    Instruction Manual AirSanitizer Warning symbol Type of hazard Warning of general danger Warning of electrical voltage Warning of pointed objects and sharp edges Warning of rotating parts Warning of tilting parts Warning of suspended load Table 2: Warning symbols of situation-related dangers 2.2 Personal protective equipment...
  • Page 9: Indications For Minimizing Specific Hazards

    Instruction Manual AirSanitizer FFP3 respiratory protection: FFP3 respiratory protection is used to protect against contaminated material, such as aerosols, harmful dusts, etc. Table 3: Symbols of personal protective equipment 2.3 Indications for minimizing specific hazards Danger due to lack of missing or improper maintenance...
  • Page 10: Assembly Instructions For Safe Operation

    Instruction Manual AirSanitizer Dangers during standstill If the AHU is at a standstill, e.g. in the event of a power failure, the AHU must be disconnected from the power supply by using the power plug, as described above, and secured against unintentional reconnection before opening the AHU. Only...
  • Page 11: Reception Control / Transportation / Unloading / Storage

    When the AHUs arrive, please check the scope of delivery for completeness and damage im- mediately. Scope of delivery: o EUROCLIMA air purifier o Instruction manual (loose in transport bag on the outside of the AHU) o Tool wrench (hexagon socket / Allen bit 5 mm) (loose in the transport bag on the out-...
  • Page 12: Transportation By Forklift / Lift Truck

    Instruction Manual AirSanitizer Before further lifting, check by visual inspection that no conspicuous defor- mations can be detected on the suspension means. Avoid jerky lifting. Loads must be picked up and set down in such a way that unintentional over- turning, falling apart, sliding or rolling of the load is avoided.
  • Page 13: Storage

    Instruction Manual AirSanitizer Figure 4: Center of gravity centrally between the forks 3.3 Storage The AHU is generally packed in nylon. This package is suitable to protect the AHU during loading and unloading from bad weather, but not for outdoor storage. The insertion into a dry area after un- loading is therefore essential for the preservation of the AHU.
  • Page 14: Foundation

    Instruction Manual AirSanitizer 1. The mounting bracket supplied loose (see Figure 5) is to be fixed to the rivet nuts at the rear of the AHUs blow out hood in exact alignment using the enclosed fixing screws (see Figure 6), see Figure 7.
  • Page 15: Erection

    Instruction Manual AirSanitizer 4.4 Erection 4.4.1 Potential risks that may arise at the erection site Cleaning work - including wet cleaning - can be carried out on the inside and outside of the AHU. During this work, leakage / dripping of cleaning fluid is possible.
  • Page 16: Commissioning

    Instruction Manual AirSanitizer Commissioning 5.1 Preliminary steps Clean thoroughly the AHU and all components of dust, swarf, and other debris. Remove all loose parts like tools, documentation, etc. from the AHU. Such parts can be sucked in by the fan and lead to its destruction.
  • Page 17: Noise Data

    Instruction Manual AirSanitizer Danger due to rotating parts Before opening the service door, all current-carrying parts, e.g. fan, etc., must be disconnected from the power by using the power plug and the overrun time of the fan must be considered. The instructions in chapter 2 (Safety instructions) must...
  • Page 18: Maintenance

    VDI 6022 sheet 1 and VDMA 24186 part 1. Please note that EUROCLIMA is not responsible for damage caused by improper handling of sol- vents and cleaning agents, and not liable for mechanical damage. Solvents and cleaning agents may not contain alcohol for use on coated surfaces.
  • Page 19: Electrical Connection

    Instruction Manual AirSanitizer 7.1 Electrical connection All electrical connections must be inspected annually and deficiencies (e.g. loose cable strands, loose screw, clamp connection, etc.) must be identified and eliminated immediately. Any dust de- posits must be removed regularly. The AHU is secured with a micro fuse F1 3.15 A (see Figure 1, in chapter 1.5.1 (Overview / con- struction of the AHU)).
  • Page 20: Air Filters

    AirSanitizer 7.3 Air filters EUROCLIMA recommends changing the filter outside the period of use to reduce the risk of infec- tion for other persons. When checking and changing the filters, disposable gloves and FFP3 respir- atory protection must be used. The soiled filters must be disposed of in closed waste bags and in accordance with local regulations.
  • Page 21: Hepa Filter H 13 (En 1822:2019)

    Instruction Manual AirSanitizer 7.3.2 HEPA filter H 13 (EN 1822:2019) The HEPA filter must be checked regularly (according to maintenance plan Table 6) for degree of contamination, damage, odor, and moisture penetration. For inspection, cleaning and mainte- nance, the HEPA filter must be pulled out (upper filter, see Figure 15).
  • Page 22 Instruction Manual AirSanitizer Components (examples) Material CER / EWC European Waste Code Casing panels, built-in com- VZ and VZB sheet metal 170405 ponents, base frames Aluminum 170402 Copper cable Copper cable 170411 Casing insulation Mineral wool 170604 Air filter Plastic, metal...
  • Page 23: Circuit Diagram

    Instruction manual AirSanitizer Circuit diagram 22/28 V12-20.0...
  • Page 24: Declaration Of Conformity

    Instruction Manual AirSanitizer 10 Declaration of conformity 10.1 Declaration of conformity S-Version V12-20.0 23/28...
  • Page 25: Declaration Of Conformity M-Version

    Instruction Manual AirSanitizer 10.2 Declaration of conformity M-Version 24/28 V12-20.0...
  • Page 26: Nameplate

    Instruction Manual AirSanitizer 11 Nameplate 11.1 Nameplate S-Version Figure 16: Nameplate S-Version V12-20.0 25/28...
  • Page 27: Nameplate M-Version

    Instruction Manual AirSanitizer 11.2 Nameplate M-Version Figure 17: Nameplate M-Version 26/28 V12-20.0...
  • Page 28 Instruction Manual AirSanitizer Figure index Figure 1: Construction air purifier “AirSanitizer” ................5 Figure 2: Correct transport ......................11 Figure 3: Incorrect transport ......................11 Figure 4: Center of gravity centrally between the forks ..............12 Figure 5: Mounting bracket (supplied loose) ................. 13 Figure 6: Fixing screw for mounting bracket .................
  • Page 29 Instruction Manual AirSanitizer Notes: ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ 28/28 V12-20.0...
  • Page 30 ZHK INOVA + KonAir AIRWALL FAN COIL UNITS SHUT-OFF, MIXING AND BALANCING DAMPERS Euroclima V12-20.0 Due to it’s commitment of continuous product development and improvement, Euroclima reserves the right to change specifications without notice. © Copyright by euroclima.com / fotolia.com...

Table of Contents