Advertisement

USER MANUAL
TLU 600/610
REMOTE CONTROLLER
NOSP 14540 Revision: 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TLU 600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TELEDYNE OLDHAM SIMTRONICS TLU 600

  • Page 1 USER MANUAL TLU 600/610 REMOTE CONTROLLER NOSP 14540 Revision: 11...
  • Page 2 User Manuals in other languages are available on Website https://teledynegasandflamedetection.com Copyright  December 2020 by TELEDYNE OLDHAM SIMTRONICS S.A.S. All rights reserved. No reproduction of all or part of this document, in any form, is permitted without the written consent of TELEDYNE OLDHAM SIMTRONICS S.A.S.
  • Page 3 SIMTRONICS, even though they may be involved in the sale of TELEDYNE OLDHAM SIMTRONICS products. TELEDYNE OLDHAM SIMTRONICS shall not be responsible for any direct or indirect damage, or any direct or indirect consequence, resulting from the sale and use of any of its products UNLESS SUCH PRODUCTS HAVE BEEN SELECTED BY TELEDYNE OLDHAM SIMTRONICS ACCORDING TO THE APPLICATION.
  • Page 4 TLU 600/610 REMOTE CONTROLLER USER MANUAL SIMTRONICS by TELEDYNE OLDHAM SIMTRONICS personnel or by personnel authorized by TELEDYNE OLDHAM SIMTRONICS. Important Information The modification of the material and the use of parts of an unspecified origin shall entail the cancellation of any form of warranty.
  • Page 5: Table Of Contents

    TLU 600/610 REMOTE CONTROLLER USER MANUAL Table des matières Introduction ..................7 Identification et marking ................7 Fonctions ....................... 8 Remote controller construction ..............8 Certification ..................11 Operation ..................13 Switching ON ....................... 13 Password ....................... 13 Menu........................13 Pictograms ......................
  • Page 6 TLU 600/610 REMOTE CONTROLLER USER MANUAL NOSP 14540 Revision: 11...
  • Page 7: Introduction

    The remote controller is intrinsically safe for use in explosive areas. Identification et marking Model TLU 600 displays European (ASCII) characters, whilst model TLU 610 displays the Cyrillic alphabet. The manufacturer’s label, located at the back of the battery compartment, carries the following...
  • Page 8: Fonctions

    USER MANUAL Functions The TLU 600/610 universal remote controller is used to exchange data with the telecapteur. This dialogue is based on a tree of on-screen menus and the use of function keys. It simplifies every operation connected with maintenance, calibration, etc. The amount of usable functions will depend upon the telecapteur involved.
  • Page 9 TLU 600/610 REMOTE CONTROLLER USER MANUAL Figure 2 : the remote controller The case is made up of two parts: the cover which carries the keypad, the main body which carries the LCD screen, electronics and charger connector, and the battery compartment.
  • Page 10 TLU 600/610 REMOTE CONTROLLER USER MANUAL The case has an infra-red communication window at the front and a charger connector socket on the left-hand side. The parts are assembled using crosshead self-tapping screws and the waterproofness is assured by charged seals graphite.
  • Page 11: Certification

    TLU 600/610 REMOTE CONTROLLER USER MANUAL 2 Certification The equipment was designed and built to comply with the European directive 2014/34/UE for products able to work in explosive atmosphere (usually called ATEX directive) which, for the certified devices is shown on the label by the symbol , the class of protection and the approv number obtained by a certified laboratory.
  • Page 12 TLU 600/610 REMOTE CONTROLLER USER MANUAL NOSP 14540 Revision: 11...
  • Page 13: Operation

    TLU 600/610 REMOTE CONTROLLER USER MANUAL 3 Operation Switching ON The remote controller is switched ON by pressing the ON/OFF key at the bottom right of the keypad (see Figure 2). The remote controller then runs a self-test routine. The character set is then displayed on the LCD screen, then gives access to the menus.
  • Page 14 TLU 600/610 REMOTE CONTROLLER USER MANUAL 3.3.1 Language choice To change the language of the remote controller: Go to the menu Setting/Language, Choose English or French, Then go out the menu pressing at the bottom "Esc" or "«". The telecapteur will recognize automatically the language from the Serie 63).
  • Page 15 The label is an 8-character identity chosen by the customer and allocated to the telecapteur during its manufacture in the TELEDYNE OLDHAM SIMTRONICS factory. Press key 1 to begin the dialogue with this telecapteur. It may be that there is more than one sensor in the remote controller’s field of view. A list of them...
  • Page 16: Pictograms

    This makes it easier to identify the selected sensor and shows that communication is taking place. Pictograms Several symbols called pictograms are used to simplify TLU 600/610 operation. These pictograms appear in the right-hand column (20 column of the screen).
  • Page 17 TLU 600/610 REMOTE CONTROLLER USER MANUAL 3.4.3 Connection indicator: " " Once dialogue with the sensor has been established, the " " pictogram appears on the right of the screen. It remains on-screen until the connection is broken. Figure 8 : connection indicator...
  • Page 18 TLU 600/610 REMOTE CONTROLLER USER MANUAL Figure 10 : poor communication indicator 3.4.5 Battery recharging Only the charger supplied with the remote controller is to be used to recharge the battery; using any other charger risks permanent damage to the remote controller. It carries the label TLU600.
  • Page 19 TLU 600/610 REMOTE CONTROLLER USER MANUAL In case of emergency, it’s possible to interrupt the fast load to use the remote controller, but with a reduced battery capacity. The battery can be subjected at some hours of slow load, without damage, but the permanent charge is not advised.
  • Page 20 TLU 600/610 REMOTE CONTROLLER USER MANUAL NOSP 14540 Revision: 11...
  • Page 21: Caractéristiques Techniques

    TLU 600/610 REMOTE CONTROLLER USER MANUAL 4 Technical Specifications Operating temperature: -20°C to 50°C, Self-powered operation: 4 hours, Power supply: Rechargeable NiMH batteries, Dimensions (maxima): 227 Long x 120 Wide x 70 Deep, Weight: 0,87 kg. NOSP 14540 Revision: 11...
  • Page 22 TLU 600/610 REMOTE CONTROLLER USER MANUAL NOSP 14540 Revision: 11...
  • Page 23: Maintanance

    TLU 600/610 REMOTE CONTROLLER USER MANUAL 5 Maintenance To be done out of ATEX area Cleaning Take care not to scratch the infra-red communication window. Changing a battery unit To change the battery unit: remove the battery compartment by undoing the 6 cross-head screws.
  • Page 24 TLU 600/610 REMOTE CONTROLLER USER MANUAL NOSP 14540 Revision: 11...
  • Page 25: Packaging And Transport

    TLU 600/610 REMOTE CONTROLLER USER MANUAL 6 Packaging and transport Whenever the equipment is to be transported (for repair, etc.), it is advisable to pack the remote controller and its accessories in their original packaging. NOSP 14540 Revision: 11...
  • Page 26 TLU 600/610 REMOTE CONTROLLER USER MANUAL NOSP 14540 Revision: 11...
  • Page 27: Storage

    TLU 600/610 REMOTE CONTROLLER USER MANUAL 7 Storage Store the remote controller in a dry, dust-free area at a temperature in the range -20 to +45°C. NOSP 14540 Revision: 11...
  • Page 28 TLU 600/610 REMOTE CONTROLLER USER MANUAL NOSP 14540 Revision: 11...
  • Page 29: Ue Conformity Declaration

    TLU 600/610 REMOTE CONTROLLER USER MANUAL 8 UE conformity declaration NOSP 14540 Revision: 11...
  • Page 30 TLU 600/610 REMOTE CONTROLLER USER MANUAL NOSP 14540 Revision: 11...
  • Page 31 TLU 600/610 REMOTE CONTROLLER USER MANUAL NOSP 14540 Revision: 11...
  • Page 32 Jinzang Road TX 77429, 62027 ARRAS Cedex, Shanghai Free Trade Zone FRANCE China Tel.: +1-713-559-9200 Tel.: +33 (0)3 21 60 80 80 Tel.: +86-134-8229-5057 www.teledynegasandflamedetection.com © 2020 Teledyne TELEDYNE OLDHAM SIMTRONICS. All right reserved. NOSP 14540 Revision 11 /December 2020...

This manual is also suitable for:

Tlu 610

Table of Contents