  • Page 1 │ E-CIRCUIT – User Manual and Installation Guide 97, rue de Vaudreuil, Boucherville (Quebec) J4B 1K7 Phone: (450) 449-1499 Fax: (450) 641-4657 Toll-free: 1 877 667-2321 ** IMPORTANT ** PLEASE READ PRIOR TO INSTALLATION AND START UP...
  • Page 2: Table Of Contents

    Overview of the E-Circuit........................3 Installation Guide – E-Circuit Retrofit ...................... 4 Installation of an E-Circuit Electrical System on an Existing Norbec CL Door ..........4 Installation Guide – Installation of the Electrical System Components ............. 5 Installation of the Electrical System Components ..................5 Installation Procedure –...
  • Page 3: Overview Of The E-Circuit

    │ E-CIRCUIT – Installation Guide and User Manual Overview of the E-Circuit The E-Circuit is a system for automating the opening and closing of Norbec CL sliding doors. The system consists of a transformer and a motor. 120-Vac, 60 Hz power supply...
  • Page 4: Installation Guide - E-Circuit Retrofit

    │ E-CIRCUIT – Installation Guide and User Manual Installation Guide – E-Circuit Retrofit Installation of an E-Circuit Electrical System on an Existing Norbec CL Door 1. Remove the end stops at each end, as well as the cast-iron latch stop.
  • Page 5: Installation Guide - Installation Of The Electrical System Components

    │ E-CIRCUIT – Installation Guide and User Manual Installation Guide – Installation of the Electrical System Components For the installation of the sliding door and frame, refer to the CL-1650 sliding door installation guide annexed to this document. Installation of the Electrical System Components 1.
  • Page 6 │ E-CIRCUIT – Installation Guide and User Manual Opening stop – Right opening 2. Attach the end of the belt to the small anchor on the door’s closing side. 3. Run the belt through the pulley assembly and around the gear.
  • Page 7 │ E-CIRCUIT – Installation Guide and User Manual 4. Unscrew the movable pulley as much as possible with a 5 mm Allen key to move the pulley to the right (5 mm ± 3/16 in.). 5. Attach the other end of the belt to the anchor on the door’s opening side.
  • Page 8 │ E-CIRCUIT – Installation Guide and User Manual 7. Hold the mobile pulley in position. 17 mm wrench or adjustable wrench. 8. Add the cover to the pulley assembly.
  • Page 9: Installation Procedure - Pull Cord Switches (×2 Standard)

    2. Run the cables along to the transformer box. 3. Run the cables through the sealed grommet under the transformer. 4. Connection in the transformer according to the following connection diagram: *See p. 18 for the complete E-Circuit Wiring Diagram...
  • Page 10: Installation Procedure - Anti-Pinch Safety Edge (Standard)

    │ E-CIRCUIT – Installation Guide and User Manual Installation Procedure – Anti-Pinch Safety Edge (Standard) The anti-pinch safety edge installed on the door serves as a mechanical safety edge. 1. Attach plate A2 to the door jamb according to these dimensions: HT = 1,500 mm [59 in.]...
  • Page 11 4. Run the cable through the sealed grommet on the top of the motor. 5. Connect the cables according to the following diagram. Terminal M5 *See p.18 for the complete E-Circuit Wiring Diagram 6. Select the switch and commutator near terminal M5 of the motor housing. Option...
  • Page 12 │ E-CIRCUIT – Installation Guide and User Manual Figure 1: Installation Diagram – Anti-Pinch Safety Edge...
  • Page 13: Synchronization Procedure - Radio-Controlled (Optional)

    │ E-CIRCUIT – Installation Guide and User Manual Synchronization Procedure – Radio-Controlled (Optional) START command option: Radio-controlled button ↓ Radio-Controlled pull switch ↓ Setup Steps 1. Power up the system. 2. Open the motor housing cover. 3. Press button P1 on the internal radio receiver once.
  • Page 14: Installation Procedure - Photoelectric Safety Barrier (Optional)

    │ E-CIRCUIT – Installation Guide and User Manual Installation Procedure – Photoelectric Safety Barrier (Optional) 1. Screw the bracket and the sensor onto the door underneath the safety nose. 2. Run the cabling along the edge and top of the door toward the motor housing.
  • Page 15 Installation Guide and User Manual 5. Connect the cables according to the following diagram. Terminal M5 *See p. 18 for the complete E-Circuit Wiring Diagram 6. Select the switch and commutator near terminal M5 of the motor housing. Option Switch...
  • Page 16: Installation Procedure - Contactless Opening Motion Sensor (Optional)

    2. Run the cables along to the transformer box. 3. Run the cables through the sealed grommet under the transformer. 4. Connect to the transformer according to the following connection diagram: *See p. 18 for the complete E-Circuit Wiring Diagram...
  • Page 17 │ E-CIRCUIT – Installation Guide and User Manual 5. Follow the procedure for changing parameters and change parameter = 1. 6. Calibrate the operating distance. 7. Operates as follows.
  • Page 18: E-Circuit Wiring Diagram

    │ E-CIRCUIT – Installation Guide and User Manual E-Circuit Wiring Diagram...
  • Page 19: User Manual

    │ E-CIRCUIT – Installation Guide and User Manual User Manual Operating and Configuration Instructions ← Keypad 1. Partial 2. Menu 3. Open Housing → Pull switch – Start Display During normal operation, the screen displays the following information: Display Description...
  • Page 20: Electronic Obstacle Detection

    │ E-CIRCUIT – Installation Guide and User Manual Electronic Obstacle Detection Electronic obstacle detection is active when opening and closing. When it is operating, it reverses the door’s movement without disabling automatic closure. If detection occurs twice consecutively, the door’s movement is reversed by 4 in. [10 cm] and goes to the STOP position.
  • Page 21: Partial Opening

    │ E-CIRCUIT – Installation Guide and User Manual Partial Opening By pressing the Partial button, the door will open partially based on parameter , the automatic closure parameter is ignored, and the door stays open until another start command is received.
  • Page 22: Configuration Of Safety Options

    │ E-CIRCUIT – Installation Guide and User Manual Configuration of Safety Options Before connecting the power supply, switches FT1 and FT2, as well as the commutators, near terminal M5 of the motor housing, must be adjusted depending on the options.
  • Page 23: Running The Learning Phase After A Power Failure

    │ E-CIRCUIT – Installation Guide and User Manual Running the Learning Phase After a Power Failure When the device is turned on after a power failure, the screen will display and the light will turn on. You must: 1. Open the door manually by about 20 in. [50 cm], if the door is closed.
  • Page 24: Table Of Alarms And Problems

    Relay activates when the door closes Relay activates when the door opens Interlocking Zero distance 0–40 [mm] Reset the card to save search Exit setup mode * Disregard for E-Circuit Table of Alarms and Problems Problem Display Cause Solution The door does The screen is...
  • Page 25 │ E-CIRCUIT – Installation Guide and User Manual The screen Buffer battery level too Restore power from the electrical low; the system grid. displays prevents movement when power levels are low. The door opens The screen Safety options are Check the photoelectric barrier’s...
  • Page 26: Annex - Installation Guide Cl-1650

    │ E-CIRCUIT – Installation Guide and User Manual Annex – Installation guide CL-1650...
  • Page 27 │ E-CIRCUIT – Installation Guide and User Manual...
  • Page 28 │ E-CIRCUIT – Installation Guide and User Manual...
  • Page 29 │ E-CIRCUIT – Installation Guide and User Manual...

Table of Contents