Do you have a question about the Oriel 60000 Q and is the answer not in the manual?
Questions and answers
Summary of Contents for Newport Oriel 60000 Q
Page 1
Phone: (203) 377-8282 (800) 714-5393 Fax: (203) 378-2457 E-MAIL: oriel.sales@newport.com SERIES Q HOUSING MODELS 60000, 60030 ANUAL Please read these instructions completely before operating this equipment. The specification and operating instructions apply only to the model(s) covered by this manual. If there are any questions or problems regarding the use of this equipment, please contact New port or the representative from w hom this equipment w as purchased.
M60000 SERIES Q CONVECTIVE LAMP HOUSING TABLE OF CONTENTS INTRODUCTION ................................4 SAFETY CONSIDERATIONS............................9 RA DIATION ..............................9 LAMP EXPLOSION - XENON A ND MERCURY ARC LA MPS .............9 OZONE ..............................10 ELECTRICAL............................10 EMI ................................11 HEA T...............................11 GENERAL DESCRIPTION ............................12 LAMP AND REFLECTOR A DJUSTMENTS ..................12 LAMP COOLING ............................12 OPTIONAL CONDENSING LENS ASSEMBLIES ................12 MOUNTING ............................12...
Page 3
M60000 SERIES Q CONVECTIVE LAMP HOUSING LIGHT COLLECTION ...............................40 14.1 COLLIMA TED BEA MS...........................41 14.2 IMA GING THE SOURCE........................42 14.3 UNIFORMITY ............................43 14.4 REAL LENSES ............................44 SPHERICAL ABERRATION .......................44 CHROMATIC ABERRATION......................45 14.5 HOW DO YOU POSITION THE CONDENSER TO GET A COLLIMA TED BEA M? ......45 ADDITIONAL OPTIONS FOR THE Q- HOUSING ....................46 15.1 ADA PTER KIT FOR INTENSITY CONTROLLER SYSTEM ...............46...
Complete Series Q Housings with a choice of lamp (and mount) are available. See Newport catalog for specific configurations. A number of accessories can be used in conjunction with the Series Q. One or more adjustable reflec tors c an be mounted on the output ports to maximize light output.
Page 5
M60000 SERIES Q CONVECTIVE LAMP HOUSING Table 1: APPROPRIATE INTERFACE KIT AND SOCKET ADAPTERS DC Arc Lamps Required Components Power Interface Socket Source Type Series Q Housing Lamp Supply Adapter 6251N 60000 Series Q Housing with 4 75 W Xe 60014 69907 60025...
Page 6
M60000 SERIES Q CONVECTIVE LAMP HOUSING Quartz Tungsten Halogen (QTH) Lamps Required Components Power Supply Source Interface Socket Full Series Q Housing Basic Type Adapter Featured Model Model 60042 (H) 10 W 6318 60090 68938 60045 (V) 60042 (H) 20 W 6319 60090 68938...
M60000 SERIES Q CONVECTIVE LAMP HOUSING SAFETY CONSIDERATIONS There are six hazards in the operation of the 60000 Series Q Lamp Housing. They are: Radiation Lamp explosion Ozone Electrical shock Heat RADIATION The high intensity UV and VIS radiation of the arc (including deuterium) lamps can permanent ly damage the cornea, lens, and retina of the eye, even causing blindness.
M60000 SERIES Q CONVECTIVE LAMP HOUSING In normal operation lamp explosions are rare and only occur after many hundreds of hours of use. However, if the lamp envelope is stressed, explosion is more likely. Stress can occ ur from improper mounting for from deterioration of the lamp envelope. OZONE Ultraviolet light can photo decompose molecular oxygen with subsequent formation of O - Ozone...
• Keep the computer away from the ignitor/power supply. • Use a different outlet and line for the computer and ignitor/power supply. • Contact Newport for special cabling (for which there will be an additional expense) to reduce EMI/associated problems.
SERIES Q CONVECTIVE LAMP HOUSING GENERAL DESCRIPTION The 60000 Series Q Lamp Housing is Newport's most modular lamp housing. Figure 3 shows the components available for the 60000 to convert it from an arc to incandescent to deuterium to ceramic element lamp housing.
M60000 SERIES Q CONVECTIVE LAMP HOUSING CONFIGURATION OPTIONS AND ACCESSORIES INTERFACE KITS You can operate arc, quartz tungsten halogen, deuterium lamps, and IR sources in the S eries Q Housing by changing the interface kit and socket adapter. Table 1 list the appropriate kits and socket adapters for each source.
M60000 SERIES Q CONVECTIVE LAMP HOUSING ARC LAMP KIT MODEL 60010, 66017 Arc lamp interface kit, Model 60010 & 66017. Socket adapter for: 100W Hg Model 60012 50W Hg Model 60013 75W Xe Model 60014 100W Xe Model 60014 0.5 J Large Bulb XE use Model 60019 To install these components and to make electrical connections, follow the steps listed below: Interface Panel #60010 is designed for internal electrical connections to 75-Watt and100-Watt Xenon...
M60000 SERIES Q CONVECTIVE LAMP HOUSING FOR MERCURY LAMPS: FOR XENON LAMPS: NOTE MAKE SURE ALL ELECTRICAL CABLES ARE PROPERLY CONNECT ED; POSITIVE TO POSITIVE; NEGATIVE TO NEGATIVE AND THAT THE LAMP TERMINALS ARE CORRECTLY ORIENT ED AS SHOWN IN THE ILLUSTRATIONS.
M60000 SERIES Q CONVECTIVE LAMP HOUSING INSTALLATION OF VENTS (See Figure 8) 1. Remove cover plates, item 1, from unused ports on sides of housing. Save the cover plates for future use with other interface kits should your application change. 2.
M60000 SERIES Q CONVECTIVE LAMP HOUSING ARC LAMP KIT MODEL 60025 Arc lamp interface kit, Model 60025. Socket adapter for: 100W Hg use Model 60012 50W Hg use Model 60013 75W Xe use Model 60014 100W Xe use Model 60014 To install these components and to make electrical connections, follow the steps listed below: Interface Panel #60025 is designed for internal electrical connections to 75-Watt and 100-Watt Xenon Lamps and 50 and 100-Watt Mercury Lamps.
M60000 SERIES Q CONVECTIVE LAMP HOUSING INSTALLATION OF INTERLOCK ACTUATOR (See Figure 10) 1. Remove the existing interlock actuator by removing the (3) screws, item 1 as shown. Be careful not to lose the pieces, item 2 inside the housing. Store this interlock actuator and screws for future use with other interface kits should your application change.
M60000 SERIES Q CONVECTIVE LAMP HOUSING QTH AND IR ELEMENT INTERFACE KIT MODEL 60020 Interface Kit, Model 60020, is designed for internal electrical connections to: 1. Tungsten halogen light sources 2. Glow bar IR elements 3. IR Ceramic Glowers The mount consist of the following components (see Figure 11) 1.
M60000 SERIES Q CONVECTIVE LAMP HOUSING DEUTERIUM INTERFACE KIT MODEL 60093 Interface kit, Model 60093, is designed for internal connections to any of the Oriel 30 watt deuterium lamps inside the Oriel Series Q Housing. The model 60093 consists of: 1.
M60000 SERIES Q CONVECTIVE LAMP HOUSING Secure the lamp in place using the two retaining springs, item 6, by passing the loos e end of each spring around the lamp and slipping the end loop of the spring over the s et s c rew extending from the guide.
M60000 SERIES Q CONVECTIVE LAMP HOUSING DEUTERIUM INTERFACE KIT MODEL 60023 Interface Panel #60023 is designed for internal electrical connections to DC Deuterium Lamps. NOTE: The XYZ-Positioner shown in Figure 13 is not included with this kit. The kit consists of the following components: (See Figure 13) 1.
M60000 SERIES Q CONVECTIVE LAMP HOUSING 10. PULSED DEUTERIUM INTERFACE KIT MODEL 60024 INSTALLATION OF INTERFACE KIT 10.1 (See Figure 14) 1. Remove the shell from the Q-housing and install the panel as described in section 4.1 step 1. 2. Place the panel, item 1, on the recessed side of X, Y, Z positioner base item 7. 3.
M60000 SERIES Q CONVECTIVE LAMP HOUSING 11. CAPILLARY AND GUIDED LAMP INTERFACE KIT MODEL 66015, 66016 1. Remove the shell from the Q-housing and install the panel as described in section 4.1 steps 1 and 2. 2. Place the panel of the interface kit, item 2, on the recessed side of the X, Y, Z positioner base, and secure with (2) screws #6-32 X 3/8 long, item 3.
M60000 SERIES Q CONVECTIVE LAMP HOUSING 12. QTH AND IR INTERFACE KIT MODEL 60090 Interface Kit, Model 60090, is designed for internal electrical connections to: 1. Tungsten halogen light sources 2. Glow bar IR elements 3. IR Ceramic Glowers The mount consist of the following components (see Figure 17): 1.
M60000 SERIES Q CONVECTIVE LAMP HOUSING 13. ADJUSTMENT OF LAMP, MIRROR AND LENS WITH THE 60005 REFLECTOR ASSEMBLY GENERAL 13.1 In these housings, the optional 60005 Reflector Assembly collects radiation behind t he sourc e, increasing output by up to 60% with arc lamps. You can also get more output for QTH lamp. This option is not for use with Deuterium lamps or infrared sources.
M60000 SERIES Q CONVECTIVE LAMP HOUSING LAMP OPERATION AND COOLING 13.4 These arc lamps should be operated close to their rated power. Dropping the power below 80% of rated, can lead to unusual lamp performance, eventual instability, and shortened life. With mercury lamps it can also lead to cooling problems.
The lens operates at a higher F/#. *See the Newport catalog for a comprehensive discussion on aberrations. To simplify the discussion, we first describe the operation of an ideal lens and then some of the major results of...
Most arc sources are non-uniform and are not circular. Therefore, the divergence in one plane is not the same as that in the orthogonal plane. For most design purposes, the arc sizes quot ed in the Newport catalog and the lens focal length give a good guide to divergence. Figure 20 : Collimated Beam...
You can re-image the source with one of the collimating condensers by positioning the condenser further from the source using the focusing lever. The Newport catalogue describes imaging and provides the formula. As the condenser lens is moved out, the image moves in and becomes smaller.
For most design purposes, the arc sizes quot ed in the Newport catalog and the lens focal length give a good guide to divergence. For low divergence beams you should consider the small arc sources and, if necessary, use our S patial Filter Assembly (Newport catalog).
M60000 SERIES Q CONVECTIVE LAMP HOUSING REAL LENSES 14.4 The condenser lenses are intended for efficient light collection. They operat e at low F/#s . A s a result the single element F/0.85 and F/1 lenses suffer from severe aberrations, particularly spherical aberration.
(f) for a fused silica lens from the visible value of f to 0.91 f at 250 nm may require a change of lens for optimum performance. Contact Newport for details. Figure 24 : Chromatic aberration: different wavelengths are focused at different points HOW DO YOU POSITION THE CONDENSER TO GET A COLLIMATED BEAM? 14.5...
M60000 SERIES Q CONVECTIVE LAMP HOUSING 15. ADDITIONAL OPTIONS FOR THE Q-HOUSING ADAPTER KIT FOR INTENSITY CONTROLLER SYSTEM 15.1 The Oriel Model 68950 Digital Exposure Controller interfaces with several Oriel Power S upplies to maintain a constant light level regardless of lamp aging, line voltage variations, or c hanges in ambient temperature.
M60000 SERIES Q CONVECTIVE LAMP HOUSING HEAT ISOLATOR ADAPTER KIT 15.2 The optional Oriel Model 68954 Adapter Kit mounts the sensing head with the filter holder (included) to the Oriel Q Series housing. See figure 26 Figure 26. Figure 26 : 68954 Adapter Kit Mounting to the Q Series Housing The Q housing transfers most of its heat out through the surface.
Page 48
M60000 SERIES Q CONVECTIVE LAMP HOUSING Computer or other triggering device.
The simple circuit is located inside the Lamp Housing. After removal of all power, check inside the housing for a broken wire. iii. If you cannot trace the fault, contact Newport for advice. Do not operate t he Lamp Housing with a defeated interlock.
Page 50
M60000 SERIES Q CONVECTIVE LAMP HOUSING the voltage is too low, the lamp is being overcooled. If the lamp is running at its rated power but the lamp voltage is too high and the current is too low, it is being under cooled. Recommended Procedures: 1.
Domenic Assalone Bruno Rety Authorized to compile technical documentation Site Manager, Oriel Products Division Group Director, PPT Instrument and Motion Europe 150 Long Beach Boulevard Micro-Controle Division of Newport Corporation Stratford, CT 06615 Zone Industrielle 45340 Beaune la Rolande, France...
RMA on the returned equipment’s box. Equipment returned without a RMA may be rejected by the Newport Receiving Department. Equipment returned under warranty will be returned with no charge for the repair or shipping. Newport will notify you of any repairs not covered by the warranty, with the cost of the repair, before starting the work.