1. INTRODUCTION Spectro-UV (for instances when UV exposure is unavoidable). • Do not leave the exposed sensor head under the 1.1 GENERAL light source any longer than necessary to take The AccuPRO™ XP-2000A Meter features an advanced measurements. Prolonged exposure can result in...
See Section 8 for additional calibration-related AC Battery Charger information. (North American plug shown, see If recalibration is required, Contact Spectro-UV at replacement parts for complete list) 1-516-333-4859 for assistance. 2.5 ENVIRONMENTAL SPECIFICATIONS The AccuPRO meter series components are designed to be safe under the following conditions: •...
3. BUTTONS AND CONTROLS MENU Key: Adjust settings, confirm choices UP Key: DOWN Key: Toggle VIS/UV Reset PEAK Value • The keypad on the readout meter is equipped with three pressure-sensitive buttons that provide easy access to all functions and features. •...
5. USING AccuPRO 5.4 SENSOR WAVELENGTHS & RANGES 5.1 ON/OFF The single sensor attached to the AccuPRO will Press and hold the MENU button to turn the meter on. Press and hold the MENU button to turn the meter ON. display UV-A (365nm) readings as well as visible light Boot screen below followed by Information screen The Boot Screen (below) will load, followed briefly by...
The example below shows the available units for The SETTINGS menu contains the options displayed ultraviolet light: below: Upon pressing MENU, a brief confirmation screen will display (e.g., "Units set to Lux") before returning to the main menu. Simply press MENU again to return to Press UP or DOWN to highlight the feature to be Operation Mode which will display the new units.
7. INFORMATION 6.3 LANGUAGE OPTIONS All interactive features and displays of the AccuPRO The INFORMATION Screen can be accessed in the Main and AccuPRO Plus are available in English, Spanish, The INFORMATION screen, accessed via the third Menu. By default, the INFORMATION Screen briefly German, French, and Chinese.
Zeroes will appear in the Response field each time the MENU button is pressed. The text "Verify Bad" will display (as shown below) and the device will then automatically exit the calibration screen, returning to the Main Menu by default. 9.
AccuPRO in its carrying case. approximately 6 hours of operation. • While charging, it is recommended to have the device turned OFF. For product information and technical assistance, call us at 1-866-230-7305. Consult Safety Data Sheet (SDS) on our website at www.Spectro-UV.com.
Page 12
4 Dubon Ct., Farmingdale, NY 11735 866-230-7305...