Web Site, www.baytech.net. BayTech manufactures many remote site management power products and data switches. If you would like information on any of these products, please contact BayTech Customer Service at the above numbers or visit our web site.
Baytech does have a few RJ45 cable or 9-pin adaptors available for purchase. Baytech can send a PDF document of the desired cable/adaptor or you may use the pin-out chart later in the manual to make you own cable/adaptor.
Page 6
To prevent heat buildup, do not coil the power cord when in use. Do not use extension cords. Do not attempt to make any internal changes to the power source. Do not attempt to modify any portion or component of DS Series Unit unless specifically directed to by BayTech personnel. BayTech must perform any internal operations.
Handshake In. +12V when not used Signal Ground Used as a handshake line to enable/disable the receiving of characters. Adapter signals Listed are the pin specifications for the BayTech cable and adapters and the terminal COM ports: Serial 1: Port Pin out Table Signal RS-232...
Page 8
Sample: RJ08X007 Standard Rollover Cable – RJ45 to RJ45 Serial 2: RJ08X007 Pin out Serial 3: RJ45 Receptacle & Plug Sample 9-pin Adapters Serial 4: 9FRJ45PC-1 Adapter Pin Out Serial 5: 9FRJ45PC-4 Adapter Pin out (Use with RJ08X007 Cable and B/C switch in “B”)
Serial Setup Connect the 9FRJ45PC-4 adapter to the user’s computer Connect the MODULE EIA-232 port to the adapter via the RJ08X007 rolled flat ribbon cable. Use terminal emulation software to access the unit, 9600 bps, 8 data bits, 1stop bit and no parity, B/C switch set to ‘B’.
CONFIGURATION MENU: Menu 2: Module Configuration level of configuration identifies all Module Configuration modules connected to the DS-chassis. The DS71-MD4 (2)..1 Host Module DS74 (3)..2 I/O EIA232 ports DS74 has the (4) serial ports, May have more DS74 (4)..2 I/O EIA232 ports than one DS74 listed.
Set Baud Rate Select 2), from the Serial Port Configuration Menu changes the transfer rate of Select baud rate: Data bits per second for the serial port, Default is 9600 1 For 300 2 For 600 3 For 1200 4 For 2400 5 For 4800 6 For 9600 7 For 19200...
Select parity: Select 5), from the Serial Port Configuration Menu selects the Parity, 1 For None Default is None 2 For Even 3 For Odd Enter Request : RTS/DTR Line Driver Inactivity State RTS (Request to Send)/ DTR (Data Terminal Ready) is normally used in conjunction with an external modem.
Select 1, allows serial information to pass but prevents SNMP information from passing through. Select 2, enables the SNMP information to pass through along with serial data. Select either option. The module displays the DS74 Configuration menu. NOTE: Once you make a change to the port type, you have to back out of the Port Type menu and will be asked to ‘Accept changes’.
BayTech. BayTech will pay return costs for delivery within the Continental United States. All repair and return shipments must be approved by BayTech and must be accompanied by an RA (return authorization) number. Please refer to our Repair and Return Policy below.
Technical Support BayTech offers Tech Support for the lifetime of the product. A staff of Applications Engineers is on duty to assist with installation, set up or operation issues. Support is available from 8:00 a.m. to 5 p.m. (CST or CDT), Monday through Friday at the phone numbers or website provided below.
Return Authorization Process: a. Contact BayTech via Phone, Fax, or Email to get a Return Authorization (RA) Number. IMPORTANT: BayTech will not accept any returns without an RA number. b. Package the unit carefully in its original packaging or similar packaging. The warranty does not cover damage sustained during shipment.