Intelligent control and alarm system

Advertisement

TM
Cooler is Better!
IC+
Intelligent Control and Alarm System
American Panel Corporation
5800 S.E. 78th Street, Ocala, Florida 34472-3412
Phone: (352) 245-7055 Fax: (352) 245-0726
E-mail:
service@americanpanel.com
Rev. 5/11/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC+ and is the answer not in the manual?

Questions and answers

Summary of Contents for American Panel IC+

  • Page 1 Cooler is Better! Intelligent Control and Alarm System American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352) 245-7055 Fax: (352) 245-0726 E-mail: service@americanpanel.com Rev. 5/11/2020...
  • Page 2 Thank you, and congratulations on your purchase of an American Panel walk-in with Intelligent Control. We take great pride in engineering and manufacturing each of our products. With the goal of providing the highest accuracy and quality possible, our state-of-the-art manufacturing and quality control facility enables us to continually explore new technologies so that we can provide you with the finest equipment in the industry.
  • Page 3: Table Of Contents

    Introduction and Features ..........................2     Temperature Monitoring ..........................2     Temperature Alarms ............................2     Panic Alarm ..............................3     Door Open Alarm ............................3     Door Frame Heater and Window Heater Control .................... 3  ...
  • Page 4: Introduction And Features

    Introduction and Features  Intelligent Controller IC+ was designed by American Panel Corporation to control various walk‐in door devices and to monitor the  temperature of the walk‐in cabinet.  IC+ features:   Temperature Monitoring  Temperature Alarms  Panic Alarm (Optional)  Door Open Alarm   Door and Window Frame Heater Control  Electronically Controlled Light Switch and Automatic Light Off  HACCP Recording   Wi‐Fi Connectivity and Remote Notification  Intuitive User Interface  Battery Backup   Adaptive Settings  Temperature Monitoring   IC+ monitors the walk‐in cabinet temperature via a probe mounted in the warmest part of the cabinet which is near the door. The  alarm delay will ensure that the alarm does not go off during normal door openings.  For an accurate air temperature reading do not restrict the airflow over the temperature probe. To monitor the air temperature at a  different location an extended temperature probe is available for purchase.  If equipped with an extra temperature probe, IC+ will monitor the temperature at two locations or the temperature of two different  cabinets      One probe display  Two probes display  Temperature Alarms  If the temperature inside the walk‐in cabinet goes above the high alarm threshold or below the low alarm threshold, the  temperature reading on the display will blink indicating that the alarm time delay has been triggered. If the temperature does not  return to normal limits within the delay time, the buzzer will go off and the display will show the alarm message alternating with the  temperature reading. If IC+ is connected to the local Wi‐Fi network, it will send an alarm message via e‐mail.  High temperature alarm  Low temperature alarm  The buzzer can be silenced by pressing the alarm mute button.   The alarm’s set points and delay times are fully programmable to user’s needs.     ...
  • Page 5: Panic Alarm

    Default set points:    High Alarm Trigger Point (AH) Low Alarm Trigger Point Alarm Delay (AL)  (AD)  Cooler  F  Freezer  F  ‐25 40 Minutes  Beer Cooler  F  Panic Alarm  Panic alarm is an optional feature on American Panel walk‐ins. If equipped with a Panic alarm, the walk‐in cabinet will have an  illuminated red push button installed on the interior of the cabinet and an alarm buzzer with LED light install on the exterior of the  cabinet.   To trigger the alarm, push the illuminated red button mounted inside the walk‐in cabinet and an audio/visual alarm buzzer will  illuminate and sound the alarm and the IC+ controller will display the panic alarm message. If IC+ is connected to the local Wi‐Fi  network, and setup as such, it will send an alarm message via e‐mail.   To clear the alarm, push and release the panic button to depress and then press the alarm mute button on the IC+.  Door Open Alarm  IC+ controllers monitor the status of the door. If the door is not fully closed or if left open for more than the pre‐set time (5 minutes  by default) the IC+ controller will display the alarm message and the onboard buzzer will sound. If IC+ is connected to the local WiFi  network, it will send an alarm message via e‐mail.  Close the door to reset the alarm. Door Frame Heater and Window Heater Control   IC controller switches on the door frame heater and the window heater (if so equipped) when the air temperature drops  below the preset threshold of 45 F and then cycles them on and off based on a time cycle. On coolers, by default, the heaters stays  on for 35% of a 6‐minute cycle and then stays off for 65%, the cycle will repeat.  The alarm’s set points and delay times are fully  programmable to user’s needs. ...
  • Page 6: Electronically Controlled Light Switch And Automatic Light Off

    Electronically Controlled Light Switch and Automatic Light Off  The cabinet light can be switched on from the IC+ controller via the integrated light button or simply by opening the door. The IC+  will display a light bulb icon to indicate that the light is on inside the cabinet.     The Automatic Light Off feature of IC+ enables the user to save energy. The amount of time the light will stay on can be set from 1  minute to 60 minutes or can be set for manual shut off only. As default, the automatic light off feature is disabled.   Push the integrated light button on IC+ to turn the light off manually.   Back‐to‐back light control is provided as an optional feature.    NOTE: When using an occupancy sensor in conjunction with IC+, the Automatic Light Off feature must be enabled.   HACCP Recording  IC+ controller records the air temperature at preset time intervals which by default is set to 30 minutes. In addition to the air  temperature IC+ records all the alarms and door openings.  The HACCP data can be previewed on the IC+ display. To do so, push the MENU button and go to HACCP Preview →Preview Events,  select any of the events in the list to view the details related to that event.   To download the data via USB, insert a USB drive in the USB port and follow the prompts on the display.   If IC+ controller is connected to an internet enabled Wi‐Fi network, it can be setup to send periodic e‐mails containing the HACCP  data, see “Wi‐Fi Connectivity and Remote Notification” chapter of this manual. An on‐demand HACCP e‐mail option is available in  the IC+ menu at HACCP Preview →Send Email HACCP.  The retrieved data will be in a .csv format file that can be opened with Microsoft Excel or other compatible software. The name of  the file will include the date and time when the file was retrieved.   Sample HACCP file:    Wi‐Fi Connectivity and Remote Notification  IC+ is equipped with a Wi‐Fi module which enables it to connect to the local Wi‐Fi network for the purpose of sending remote  notification e‐mails for all the alarms and sending e‐mails containing HACCP data attachments.    Follow the steps below to connect the IC+ to Wi‐Fi and to set it up for remote notifications: ...
  • Page 7 1. If multiple IC+ controllers are to be connected to the same Wi‐Fi network, you must set a different serial number for each  controller in order to differentiate between them. To do so, enter the IC+ menu, go to Settings (default passcode is 7055) →  About → Serial Number. When done press “MENU” button repeatedly to exit the settings menu.  Note: When assigning different serial numbers for each controller, make a note of the serial numbers with the location for  later reference.   2. On a Bluetooth enabled device download IC+ Setup Tool app, available for IOS and Android devices.    Enable the location feature on your device and open IC+ Setup Tool app.   IC+ Setup Tool   4. Press “Scan for Devices”  5. Select from the list  6. Default Passcode is “7055”  7. Press “Outgoing Email  Server Setup”  IC+ controller will need an e‐mail account set up so it allows IC+ to access it and send e‐mails. For this purpose, American Panel  Corporation provides a generic Gmail account icpluswalkin@gmail.com; however, we recommend replacing this account with a new  one that is owned and maintained by the end user.   American Panel Corporation is not responsible for the functionality of the generic account, icpluswalkin@gmail.com and it  reserves the right to modify or discontinue the account without advance notice.   8.Outgoing Email Server Setup  In the “Select outgoing email” choose one of the available options, fill in the required information, and  press “Save Changes” when done.  Available options:  Default – select this option if you choose to keep the generic email account provided by American  Panel Corporation. No SMTP server setting required.   or  Custom – select this option if you wish to configure the SMTP settings for a preferred email account   or  Gmail, Yahoo, or AOL – select this option to configure the SMTP settings for a preferred existing email  account at one of the email servers mentioned above   Note: When using a Yahoo or AOL you must generate an app password, you can do so from the  security settings of the Yahoo or AOL email account, and then enter that password in the Password  field, see figure on the left.   Note: When using Gmail, you must turn on access to less secure apps from the security settings of  the Gmail account. Only after that IC+ will be able to access the account.   ...
  • Page 8 9. User Email Templates Setup    10. Press “Add New User  11 Enter the email address of  12. Select the type of alarms or  13. Set how often to receive  Email”  the person that will receive the  emails that this user will  the HACCP report email.   notifications.  receive. Press “Save Changes”  when done.  High Priority Alarms: Power Failure, Panic Alarm, Defective Temp. Probe  Medium Priority Alarms: High Temp. Alarm, Low Temp. Alarm  Low Priority Alarms: Door Open Alarm  Note: IC plus supports up to 5 email recipients.    TIP: To receive alarms via SMS text messages use email to text gateway. In the “Enter Email Address” field at step 11, see above,  enter the 10‐digit cellphone number you want the alarms to be texted to followed by the email domain corresponding to the  cellphone carrier. For example, to receive texts on a T‐Mobile number (123) 456 7890, enter 1234567890@tmomail.net. To find out  the email domain for your specific carrier search on the internet for “Email to text gateway list” or contact your cellphone carrier.    14. Internet Wi‐Fi Setup  Choose a Wi‐Fi network from the list, enter the password, and press connect.
  • Page 9: User Interface

    10 User Interface  ICON INDICATING THAT  THE LIGHT INSIDE THE  CABINET IS ON STEADY WI‐FI ICON INDICATES THAT THE CONTROLLER IS CONNECTED TO  CURRENT DATE  THE LOCAL NETWORK AND TIME  CURRENT CABINET  UNIT OF MEASURE,  F INDICATES TEMPERATURE  DEGREES FAHRENHEIT   WALK‐IN CABINET  LIGHT BUTTON  TYPE  USB PORT  ALARM MUTE BUTTON  MENU NAVIGATION  BUTTONS ...
  • Page 10: Navigating The Menu

    11 Navigating the Menu  To access IC+ Main Menu, push the MENU button then scroll to the desired option using the up and down buttons and press ENTER  button to confirm the selection. To go to the previous screen, press the MENU button.   The Settings Menu can be accessed from the Main Menu, the default passcode is 7055. To change any parameter, scroll to it and  press ENTER to confirm your selection. Use up and down buttons to change the parameter, when done press ENTER to confirm the  new parameter.  12 Restore the Default Settings  To restore the default settings press and hold up and down buttons for approximately 10 seconds, follow the prompts.   Note 1: Restoring the default settings will reset the access passcode to 7055.  Note 2: Restoring the default settings will not affect the WI‐FI settings.  13 Troubleshooting  Issue  Possible Cause Action  The temperature reading is flashing on and  IC+ controller detected cabinet  Make sure all the doors are closed and  off.  temperature higher or lower than the  check the temperature after few minutes  preset limits. The flashing number is the  to make sure it goes back to the normal  measured temperature inside the  range.    cabinet. The alarm will not go off until the    alarm delay time expires.  The IC+ beeps and displays the high  If the high air alarm went off, the  To silence the alarm, press the alarm  temperature alarm message.  temperature inside the cabinet is above  mute button. Check all doors to be  the preset limit. The flashing number is  closed, check the temperature setting at  the measured temperature inside the ...
  • Page 11: Field Wiring

      14 Field Wiring  Note: All field wiring must be done by a licensed electrician in compliance with the national and local electrical codes.  Note: Electrician must provide seal‐offs at every conduit entry on the warm and cold side of panels. Seal inside and around all  conduits where passing through panels.  Wire Color Code (field wiring only)  Black (1 ea) and White (1 ea)– Main power wires, terminated inside the vapor proof light fixture or stubbed out. Electrician will  provide the ground wire, see electrical schematic at chapter 14.1 of this document.   Red (1 ea) – Output to field mounted light fixture wire, terminated inside the vapor proof light fixture or stubbed out, see electrical  schematic at chapter 14.2 in this document  Brown (1 ea) – Output to remote buzzer wire, terminated inside the vapor proof light fixture or stubbed out, see electrical schematic  at chapter 14.3 in this document  Blue (1 ea) and Yellow (1 ea) – 3 WAY/Multi Way configuration wires, terminated inside the vapor proof light fixture or stubbed out,  see electrical schematic at chapter 14.4 of this document  White with blue stripe (2 ea) – alarm dry contact wires, terminated in the rectangular connection box located next to the vapor  proof light fixture, or stubbed out, see chapter 14.5 of this document.   Purple (2 ea) – evaporator fan cut out switch (closed when the door is closed), terminated in the rectangular connection box next to  the vapor proof light fixture, or stubbed out, see chapter 14.6 of this document.   14.1 Main Power  Make all the connections inside the vapor proof light fixture located on the door frame inside the walk‐in.  If an electrical stub‐out construction was requested, all the connection wires will be stubbed‐out thru the ceiling. In this case, the  field connections will be made in a junction box provided by the installer.   ELECTRICIAN MUST SEAL THE CONDUIT AT BOTH ENDS!  ...
  • Page 12: Field Mounted Light Fixture

    14.2 Field Mounted Light Fixture  ELECTRICIAN MUST SEAL THE CONDUIT AT BOTH ENDS!
  • Page 13: Panic Button For Partition Door

    14.3 PANIC BUTTON FOR PARTITION DOOR  ELECTRICIAN MUST SEAL THE CONDUIT AT BOTH ENDS!          ...
  • Page 14: Way - 4 Way Configuration And Remote Light Button

    14.4 3 WAY – 4 WAY Configuration and Remote Light Button  This configuration is typical to cabinets that have multiple doors. The user will be able to turn on and off the light from any door. ELECTRICIAN MUST SEAL THE CONDUIT AT BOTH ENDS!
  • Page 15: Alarm Dry Contact

    14.5 Alarm Dry Contact  Low voltage white with blue stipe wires are located inside the rectangular junction box, next to the vapor proof light fixture.     ELECTRICIAN MUST SEAL THE CONDUIT AT BOTH ENDS!        ...
  • Page 16: Evaporator Fan Cut-Out Switch

    14.6 Evaporator Fan Cut‐Out Switch  The pink wires are located inside the rectangular connection box, next to the vapor proof light fixture.     ELECTRICIAN MUST SEAL THE CONDUIT AT BOTH ENDS!
  • Page 17: Electrical Schematic

    15 Electrical Schematic ...