How the System Operates ..............................4 Pump Tank Features ...............................5 System Assembly ................................6 System Diagram ................................7 System Setup ..................................8 Preventive Maintenance ..............................8 Accessories ..................................9 Replacement Parts ................................9 Troubleshooting ................................10 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is above the limit requirement in SJ/T11363-2006. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Please check the product SDS carefully before using the intended product in this system. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Pilot-operated regulator provides control of fluid Screens out contaminants that may enter the pressure. inlet of the pump. Lubricant Filter Fill Hole Cover Prevents contaminants from entering the tank. Lubricant filter www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Rotate the inlet shut-off valve to the “OFF” position. Refer to the MicroCoat system operating manual for wiring the press emergency stop circuit and connecting the low level switch cable to the controller. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Regulating pressure (black hose) Fluid level switch (gray wire) Connect to emergency stop circuit NOTE: Replace the filter element (P/N 7017347) every 6 months or 1000 hours of operation. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
• To avoid pump damage, do not remove the filter screen from the pump intake. • Replace the lubricant filter (P/N 7017347) every 6 months or 1000 hours of operation. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
7017449 Filter assembly gear pump intake 7016693 Oil resistant power cord 7017347 Lubricant filter element (4) per box 7020470 Float switch kit 7022156 MicroCoat filter assembly www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
If there is binding, loosen the (2) nuts that hold the motor to the pump casting, rotate the pump casting until it is aligned and the pump runs freely. Retighten the nuts carefully. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Page 11
MicroCoat MC600 Pump System Notes www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Page 12
NORDSON EFD ONE YEAR LIMITED WARRANTY This Nordson EFD product is warranted for one year from the date of purchase to be free from defects in material and workmanship (but not against damage caused by misuse, abrasion, corrosion, negligence, accident, faulty installation, or by dispensing material incompatible with equipment) when the equipment is installed and operated in accordance with factory recommendations and instructions.