Download Print this page

RCA BTA-250M Instructions Manual page 22

Broadcast transmitter

Advertisement

OPERATION
To energize
the BTA-250M
transmitter,
close the
FILAMENT
breaker
switch.
After
the time
delay
relay has operated,
approximately
30 seconds
delay,
place the PA, MOD,
and PLATE
switches
in the
ON
position.
The
transmitter
is now
ready
for normal
operation.
To
shut
down
the transmitter,
open
the FILA-
MENT
and PLATE
switches.
Future
applications
of
power
may
be made
by simply
closing
these
two
switches.
During
operation
it is well
to check
the filament
voltage
occasionally
on the panel
meter,
and to ad-
just the FILAMENT
control
as necessary
to compen-
sate for any line voltage
fluctuations.
Increased
tube
life will
result
by operating
all tubes
at their
rated
filament
values.
Overloads
may trip the PA or the MOD
breakers
individually,
requiring
manual
reclosing
after
the
difficulty
has been remedied.
MAINTENANCE
To insure
continuous
and reliable
operation
it is
recommended
that
a definite
maintenance
schedule
be established.
It is particularly
important
that the
entire
transmitter
be kept
free from
dust and exces-
sive moisture.
Special
care should
be observed
in
the case of all insulators
to avoid
high
resistance
leaks.
A small
electric
hand
blower
may
be used
advantageously
to
blow
dust
from
inaccessible
places.
ically
for poor
contacts
and loosened
connections.
As far as possible,
tube
failures
should
be antici-
pated
by keeping
a log of tube
life
and
replacing
tubes before
actual
breakdown.
The appearance
of the transmitter
and its compo-
nents may
be kept
like
new by the judicious
appli-
cation
of the matching
lacquers
which
are included
as part of this equipment.
As an aid in servicing,
Table
7 lists typical
volt-
The transmitter
should
also be inspected
period-
ages at the tube
sockets.
TABLE 7
TYPICAL
TUBE SOCKET VOLTAGES
'
Fi'ame"t
'
Tube
Tube
Symbol
Function
~___
Volts
Pin
DC
No.
----
Vl
Oscillator
807
cap
4
20
225
3
-
2
~___~
VlOl
Buffer/
807
Driver
cap
4
42
530
3
-75
2
245
l-5
~___
345
l-5
Volts
AC
6.3
6.3
V104,S
1st AF
807
cap
240
4
36
3
9
2
V106,7
Modulator
813
cap
1,515
-
-
4
-80
3
___
___
V108,9
Rectifier
866/366A
cap
1,840AC
-
-
-
-
-
335
l-7
______
240
l-5
10
6.3
All voltages except filament voltages are measured to ground, using a high-resistance
voltmeter
22