GFA ELEKTROMATEN SG 85F Installation Instructions Manual

Si 20.100 fu-40,00

Advertisement

Quick Links

f
Installation Instructions
ELEKTROMAT
SI 20.100 FU-40,00
Model: 10004227 10011
-en-
Status: 26.03.2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG 85F and is the answer not in the manual?

Questions and answers

Summary of Contents for GFA ELEKTROMATEN SG 85F

  • Page 1 Installation Instructions ELEKTROMAT SI 20.100 FU-40,00 Model: 10004227 10011 -en- Status: 26.03.2021...
  • Page 2 GfA ELEKTROMATEN GmbH & Co. KG Wiesenstraße 81 D-40549 Düsseldorf www.gfa-elektromaten.de info@gfa-elektromaten.de...
  • Page 3: Table Of Contents

    Table of contents General safety information ....................4     Safe operation ......................... 4   Technical Data ........................ 6     Integrated safety brake ....................7     Mechanical installation ....................8     Electrical installation ..................... 12     Limit switch adjustment ....................
  • Page 4: General Safety Information

    1 General safety information Specified use The drive unit is intended for vertically moving doors that need to be secured against dropping. A safety brake is integrated into the gearbox. The drive unit must be mounted directly on the shaft of the door. The drive unit must be protected against moisture and aggressive environmental conditions (such as corrosive substances).
  • Page 5 Warning - Failure to follow these installation instructions may result in severe injury or death.  Please read these instructions before using the product.  Keep these instructions handy.  Include these instructions when passing on the product to third parties. Warning - Danger from improper use of the product! ...
  • Page 6: Technical Data

    2 Technical Data Type SG 85F Output torque 200 (200) Output speed OPEN 18-100 Output speed CLOSE 18-55 Output speed CLOSE > 2,5m 18-55 Output shaft / hollow shaft 40,00 Locking torque moment Safety brake (testhouse/approval number) 14-003612-PR03 Maximum holding torque...
  • Page 7: Integrated Safety Brake

    3 Integrated safety brake A safety brake is integrated into the gearbox of this ELEKTROMATEN. The safety brake protects against the door dropping due to breakage or wear of the gear teeth. The safety brake works regardless of the mounting position, speed and rotating direction. It is maintenance-free.
  • Page 8: Mechanical Installation

    4 Mechanical installation Prerequisites The permissible loads on walls, fastenings, mountings and transmission elements must not be exceeded, even for maximum holding torques or locking torques (▶ refer to technical data). Connection elements ▶ Self-locking connection ▶ Utilize the hole diameter ▶...
  • Page 9 Mounting Two elongated holes are provided for mounting. BAGAD0 3 0 0 1 _Z0 0 3...
  • Page 10 Installation The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation. Warning - Potential injury or danger to life!  During installation, be sure to use a lifting device that has a sufficient load- carrying capacity.
  • Page 11 ▶ Attach the drive unit. BAGAE0 3 0 0 5 _Z0 0 2 ▶ Tighten all connection elements (M12) to BAGAE0 3 0 1 0 _Z0 0 2 75 Nm. Install all other connection elements according to the specifications of the door manufacturer.
  • Page 12: Electrical Installation

    5 Electrical installation Warning - Danger to life from electric current!  Switch the mains OFF and check that the cables are de-energised  Observe the applicable regulations and standards  Make a proper electrical connection  Use suitable tools Performing electrical installation Remove the cover.
  • Page 13: Limit Switch Adjustment

    6 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel.
  • Page 14: Motor Connection

    7 Motor connection Motor X13 Motor plug Spring applied brake 8 Limit switch connection S10 Emergency manual operation BANA101101_Z001 X12 DES connection Safety circuit Channel B (RS485) Ground RS 485 Channel A (RS485) Safety circuit Supply voltage Connection cable freqency inverter (FI)
  • Page 15: Emergency Manual Operation (Emergency Hand Crank)

    9 Emergency manual operation (emergency hand crank) The emergency manual operation is designed for opening or closing the door without power supply. Its activation interrupts the control voltage. Electrical operation is no longer possible. Warning – Injuries due to incorrect operation or falling objects! ...
  • Page 16 Warning – Risk of injury due to uncontrolled movements and falling objects! The drive unit could start up unexpectedly and injure people should a wrong emergency hand crank be used. A wrong crank will drop out of the mounting and injure people.
  • Page 17: Completion Of Commissioning / Testing

    10 Completion of commissioning / testing Check the following components and after that, mount all covers. Gearbox Check drive unit for oil loss (a few drops are not critical). Protect output shaft permanently against corrosion. Safety brake in the gearbox The safety brake requires no maintenance or inspection.
  • Page 18 Emergency manual operation Function to be checked in a de-energised state. Carry out functional test only between final limit positions. Limit switches Check the final limit positions by opening and closing the door completely. The safety zone must not be reached. Brake Warning –...
  • Page 19 Entire drive unit Note!  Have the drive checked annually by a specialist.  Shorter inspection interval for frequently used doors.  Observe the applicable regulations and standards.
  • Page 20: Declaration Of Incorporation / Declaration Of Conformity

    EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Machinery Directive 2006/42/EC are met: declare under our sole responsibility that the 1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2,...

Table of Contents