IS-MDC-12 Instruction Manual LASERMET IS-MDC-12 Instruction Manual Contents Declaration of Conformity ......................3 Safety Warnings ..........................4 Concept ............................5 Summary of Evaluation of Compliance to EN ISO 13849-1:2015 ........... 5 Installation ............................6 Testing Using a Multimeter ..................... 8 Electrical Connections ......................
CODED MAGNETIC DOOR CONTACT Part no. IS-MDC-12 DECLARATION OF CONFORMITY This is to certify that the Coded Magnetic Door Contact designated by Lasermet Part Number IS-MDC-12 has been tested in accordance with the following directives and standards and found to comply.
IS-MDC-12 Instruction Manual Safety Warnings This device is intended to be used as part of a safety system which may be used to protect personnel and equipment from possible injury, damage, or loss. As such it must be installed and wired according to these instructions and tested by suitably qualified persons.
IS-MDC-12 Instruction Manual Concept The Lasermet IS-MDC-12 is a dual channel coded magnetic door safety contact. It is ideal for use in conjunction with Lasermet’s ICS range of laser interlock controllers as part of a safety interlock system. It is used to detect when a door or other moveable cover forming part of a protective enclosure is open.
IS-MDC-12 Instruction Manual Installation The Door Contact is intended for indoor benign environments. It is not suitable for use in locations exposed to rain or moisture, in areas of high humidity or corrosion. It is not certified for use in areas where an explosion hazard exists.
Page 7
On some doors the door surround (architrave) projects forward of the door face. The IS-MDC-12 will work with the switch unit up to 8mm or more in front of the actuator unit, as shown in the figure. This may reduce or eliminate the need for cutting into the architrave.
If this happens the switch should be replaced. The switch should never be opened. This will invalidate the warranty and there are no serviceable parts inside. All Lasermet ICS panels comply with this requirement. Wiring to a Lasermet ICS Interlock Control Panel ICS-6 Select an unused Interlock connector J1-J4.
Unless the cable run is exceptionally long, cable with 7/0.2mm cores are suitable. Six core cable is required unless connecting to an ICS-6, where only four cores are necessary. Lasermet can supply suitable cable to match that fitted to the switch.
Probability of dangerous failure per hour (PFH) 3.68 x 10 It is important to note that the Performance Level established for the IS-MDC-12 are those that may be achieved by the system when the board is properly integrated into a safety related part of a control system.
IS-MDC-12 Instruction Manual Warranty Lasermet provide a 12-month warranty for defects in materials and manufacture, from the date of installation or delivery. Installations completed by Lasermet are covered against defects in workmanship for 12 months. Damage or defects caused by other factors are not covered. For example, industrial contamination, incorrect cleaning, storm damage.
IS-MDC-12 Instruction Manual Contact Details Lasermet provide a full range of laser interlock equipment including interlock switches, illuminated warning signs, laser shutters, entry keypads with built-in fail-safe override timer, door locks, external power supplies etc. which can be interconnected to provide a complete system. We also supply equipment and consultancy covering all aspects of laser safety.