  • Page 1                        Topcon X25, X30, X35  Installation Manual             ...
  • Page 2         Copyright  2018 by NORAC Systems International Inc.  Reorder P/N: 74UT‐TC‐X30‐INST Rev A (Topcon X25, X30, X35 Display Installation Manual)    NOTICE:  NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update  products sold previously.  Every effort has been made to ensure the accuracy of the information contained in this manual.  The technical information in this manual  was reviewed at the time of approval for publication. ...
  • Page 3 WWW.NORAC.CA    PRECISION DEFINED Contents  Introduction .......................... 1     Technical Specifications ...................... 3     Installation  .......................... 4     Cable Schematics  ......................... 11            ...
  • Page 4: Introduction

    WWW.NORAC.CA    PRECISION DEFINED 1   Introduction  The  Topcon  X30  Display  Option  Manual  is  intended  to  be  used  in  conjunction  with  the  UC7™  Boom  Height  Control  Installation  Manual.    This  manual  provides  instructions  to  interface  the  UC7  HCM1  Module  to  the ...
  • Page 5 WWW.NORAC.CA    PRECISION DEFINED 1.1. List of Parts (Self‐Propelled Installation)  Item  Part Number  Name  Quantity  C25  50250  SWITCHBOX  1  C26  50140‐11  CABLE SWITCHBOX TEE ‐ 50250  1  C40  1015764‐01  CABLE TOPCON X25, X30 CAB INTERFACE  1  C41  1015765‐01  CABLE TOPCON CM‐40 INTERFACE  1  C42  43220‐0.5  CABLE NETWORK 14 AWG 0.5M  3  C43  43220‐10  CABLE NETWORK 14 AWG 10M  1  E08  50200  CANBUS REPEATER  1  E10  43760  NETWORK COUPLER 3‐WAY ...
  • Page 6: Technical Specifications

    WWW.NORAC.CA    PRECISION DEFINED 2   Technical Specifications  Table 1: System Specifications  Supply Voltage (rated)   12VDC  Supply Current (rated)   10A  Hydraulic Pressure (maximum)   3300 psi  Baud Rate   250 kbps  Operating Temperature Range   0°C to 80°C            Visit www.solutions.norac.ca for more system   Page 3  installation and troubleshooting info. ...
  • Page 7: Installation

    WWW.NORAC.CA    PRECISION DEFINED 3   Installation  The following steps of the installation assume that the HCM1 module and all required cables are installed.  3.1. CANbus Interface for Topcon Systems without an Apollo  Securely mount the control module (E01) in the cab of the sprayer.  Connect the ISO CAN LOOP connector on cable C40 to the CAN1/ISOBUS connector on harness AGA4700  (Figure 1 ‐ Green Box).   Connect the POWER connector on cable C40 to the SWITCHED POWER connector on harness AGA4700  (Figure 1 ‐ Red Box).   Connect the 6‐pin Deutsch plug (NORAC ECU) on cable C40 to the CANbus Repeater (E08). (Figure 1 ‐ Blue  Box).    Figure 1: CANbus Interface for Topcon Systems without an Apollo           Visit www.solutions.norac.ca for more system   Page 4  installation and troubleshooting info. ...
  • Page 8 WWW.NORAC.CA    PRECISION DEFINED 3.2. CANbus Interface for Topcon Systems with an Apollo  Securely mount the control module (E01) near the Topcon Apollo ECU.  Connect the SWITCHBOX connector on cable C41 to the SWITCHBOX connector on harness 1009865‐01 or  harness 1009864‐01 (Figure 2 ‐ Green Boxes).   Connect  the  POWER  connector  (receptacle)  on  cable  C41  to  the  SECTION  VALVE  POWER  connector  on  harness 1009865‐01 or harness 1009864‐01 (Figure 2 – Red Boxes).   Connect  the  POWER  connector  (plug)  on  cable  C41  to  the  POWER  connector  on  harness  1010282‐01  (Figure 2 – Black Boxes).  ...
  • Page 9 WWW.NORAC.CA    PRECISION DEFINED 3.3. Self‐Propelled Display Cabling Installation    Figure 3: Display Cabling Overview  NOTE:  Only parts shown in black are included with this package.  Parts shown in blue are included with the  UC7™ Boom Height Control System.  Connect cable C42 to the 6‐pin display bus connector on the HCM1 (Figure 4).   Display Bus    Figure 4: Display Bus Location  Connect  cable  C42  to  cable  C43  with  a  2‐way  coupler  with  terminator  (E20).    The  2‐way  coupler  with  terminator is WHITE.  Route cable C43 into the cab.  Connect to the 3‐way coupler (E10).      Visit www.solutions.norac.ca for more system   Page 6  installation and troubleshooting info. ...
  • Page 10 WWW.NORAC.CA    PRECISION DEFINED Connect the power cable (C30) to the 3‐way coupler (E10).    Connect the two cables C42 together with a 2‐way coupler with terminator (E20).  Connect one end to the  3‐way coupler (E10).  Connect the other end to the CANbus Repeater (E08).  Connect cable C40 (Installation without an Apollo) or cable C41 (Installation with an Apollo) to the CANbus  Repeater (E08).          Visit www.solutions.norac.ca for more system   Page 7  installation and troubleshooting info. ...
  • Page 11 WWW.NORAC.CA    PRECISION DEFINED 3.4. Pull Type Display Cabling Installation  If installing on a pull type machine, the parts listed in Section 1.2 are needed and must be ordered separately  from this kit.  Cable C43 is not used for this type of installation.     Figure 5: Display Cabling Overview  NOTE:  Only parts shown in black are included with this package.  Parts shown in blue are included with the  UC7™ Boom Height Control System.  Connect cable C42 to the 6‐pin display bus connector on the HCM1 (Figure 6).       Visit www.solutions.norac.ca for more system   Page 8  installation and troubleshooting info. ...
  • Page 12 WWW.NORAC.CA    PRECISION DEFINED Display Bus    Figure 6: Display Bus Location  Connect  cable  C45  to  cable  C42  with  a  2‐way  coupler  with  terminator  (E20).    The  2‐way  coupler  with  terminator is WHITE.  Route cable C45 to the hitch.  Connect cable C45 to cable C44 with a 2‐way coupler (E12).  The 2‐way  coupler is BLACK.  The 2‐way coupler (E12) will provide the hitch disconnect.  Route cable C44 into the cab.  Connect to the 3‐way coupler (E10).  Connect the power cable (C30) to the 3‐way coupler (E10).    Connect the two cables C42 together with a 2‐way coupler with terminator (E20).  Connect one end to the  3‐way coupler (E10).  Connect the other end to the CANbus Repeater (E08).  Connect cable C40 (Installation without an Apollo) or cable C41 (Installation with an Apollo) to the CANbus  Repeater (E08).            Visit www.solutions.norac.ca for more system   Page 9 ...
  • Page 13 WWW.NORAC.CA    PRECISION DEFINED 3.5. Switchbox Installation  Disconnect cable C20 from the HCM1 module (E01).    Insert the 12‐pin tee on cable C26 between the HCM1 module and cable C20.  Route the other end of cable 26 to the cab of the sprayer.   Install the switchbox (C25) inside the cab.  Connect the switchbox to cable C26.    If cable C26 is not long enough, a network cable and coupler are available for order from NORAC.  Item  Part Number  Name  C27  43220‐03  CABLE NETWORK 14 AWG 3M  E12  43764  NETWORK COUPLER 2‐WAY    Some sprayer types may not use all the switch functions.     Figure 7: Switchbox Installation  NOTE:  Only parts shown in black are included with this package.  Parts shown in blue are included with the  UC7™ Boom Height Control System.         ...
  • Page 14: Cable Schematics

    WWW.NORAC.CA    PRECISION DEFINED 4   Cable Schematics  4.1. Item C25:  50250 – Switchbox        Visit www.solutions.norac.ca for more system   Page 11  installation and troubleshooting info. ...
  • Page 15 WWW.NORAC.CA    PRECISION DEFINED 4.2. Item C26:  50140‐11 – Cable Switchbox Tee ‐ 50250                Visit www.solutions.norac.ca for more system   Page 12  installation and troubleshooting info. ...
  • Page 16 WWW.NORAC.CA    PRECISION DEFINED 4.3. Item C40:  1015764‐01 – Cable Topcon X25, X30 Cab Interface              Visit www.solutions.norac.ca for more system   Page 13  installation and troubleshooting info. ...
  • Page 17 WWW.NORAC.CA    PRECISION DEFINED 4.4. Item C41:  1015765‐01 – Cable Topcon CM‐40 Interface          Visit www.solutions.norac.ca for more system   Page 14  installation and troubleshooting info. ...
  • Page 18 WWW.NORAC.CA    PRECISION DEFINED 4.5. Item C42: 43220‐0.5 ‐ Cable Network 14 AWG – 0.5m              Visit www.solutions.norac.ca for more system   Page 15  installation and troubleshooting info. ...
  • Page 19 WWW.NORAC.CA    PRECISION DEFINED 4.6. Item C43: 43220‐10 ‐ Cable Network 14 AWG – 10m              Visit www.solutions.norac.ca for more system   Page 16  installation and troubleshooting info. ...
  • Page 20 WWW.NORAC.CA    PRECISION DEFINED 4.7. Item C44: 43220‐03 ‐ Cable Network 14 AWG – 3m                Visit www.solutions.norac.ca for more system   Page 17  installation and troubleshooting info. ...
  • Page 21 WWW.NORAC.CA    PRECISION DEFINED 4.8. Item C45: 43210‐15 ‐ Cable Network 18 AWG – 15m              Visit www.solutions.norac.ca for more system   Page 18  installation and troubleshooting info. ...
  • Page 22 WWW.NORAC.CA    PRECISION DEFINED   Notes          Visit www.solutions.norac.ca for more system   Page 19  installation and troubleshooting info. ...
  • Page 23     TOPCON Agriculture Canada 3702 Kinnear Place  Saskatoon, SK   S7P 0A6  TOPCON Agriculture Americas  W5527 Hwy 106  Fort Atkinson, WI   53538  TOPCON Precision Agriculture Europe  Avenida de la industria,  35, Tres Cantos, España  Spain  Support    Phone:  888 979 9509     E‐mail: tasupportn@topcon.com    Web: www.norac.ca      ...