Copyright 2018 by NORAC Systems International Inc. Reorder P/N: 74UT‐TC‐X30‐INST Rev A (Topcon X25, X30, X35 Display Installation Manual) NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in this manual was reviewed at the time of approval for publication. ...
WWW.NORAC.CA PRECISION DEFINED 1 Introduction The Topcon X30 Display Option Manual is intended to be used in conjunction with the UC7™ Boom Height Control Installation Manual. This manual provides instructions to interface the UC7 HCM1 Module to the ...
Page 5
WWW.NORAC.CA PRECISION DEFINED 1.1. List of Parts (Self‐Propelled Installation) Item Part Number Name Quantity C25 50250 SWITCHBOX 1 C26 50140‐11 CABLE SWITCHBOX TEE ‐ 50250 1 C40 1015764‐01 CABLE TOPCON X25, X30 CAB INTERFACE 1 C41 1015765‐01 CABLE TOPCON CM‐40 INTERFACE 1 C42 43220‐0.5 CABLE NETWORK 14 AWG 0.5M 3 C43 43220‐10 CABLE NETWORK 14 AWG 10M 1 E08 50200 CANBUS REPEATER 1 E10 43760 NETWORK COUPLER 3‐WAY ...
WWW.NORAC.CA PRECISION DEFINED 2 Technical Specifications Table 1: System Specifications Supply Voltage (rated) 12VDC Supply Current (rated) 10A Hydraulic Pressure (maximum) 3300 psi Baud Rate 250 kbps Operating Temperature Range 0°C to 80°C Visit www.solutions.norac.ca for more system Page 3 installation and troubleshooting info. ...
WWW.NORAC.CA PRECISION DEFINED 3 Installation The following steps of the installation assume that the HCM1 module and all required cables are installed. 3.1. CANbus Interface for Topcon Systems without an Apollo Securely mount the control module (E01) in the cab of the sprayer. Connect the ISO CAN LOOP connector on cable C40 to the CAN1/ISOBUS connector on harness AGA4700 (Figure 1 ‐ Green Box). Connect the POWER connector on cable C40 to the SWITCHED POWER connector on harness AGA4700 (Figure 1 ‐ Red Box). Connect the 6‐pin Deutsch plug (NORAC ECU) on cable C40 to the CANbus Repeater (E08). (Figure 1 ‐ Blue Box). Figure 1: CANbus Interface for Topcon Systems without an Apollo Visit www.solutions.norac.ca for more system Page 4 installation and troubleshooting info. ...
Page 8
WWW.NORAC.CA PRECISION DEFINED 3.2. CANbus Interface for Topcon Systems with an Apollo Securely mount the control module (E01) near the Topcon Apollo ECU. Connect the SWITCHBOX connector on cable C41 to the SWITCHBOX connector on harness 1009865‐01 or harness 1009864‐01 (Figure 2 ‐ Green Boxes). Connect the POWER connector (receptacle) on cable C41 to the SECTION VALVE POWER connector on harness 1009865‐01 or harness 1009864‐01 (Figure 2 – Red Boxes). Connect the POWER connector (plug) on cable C41 to the POWER connector on harness 1010282‐01 (Figure 2 – Black Boxes). ...
Page 9
WWW.NORAC.CA PRECISION DEFINED 3.3. Self‐Propelled Display Cabling Installation Figure 3: Display Cabling Overview NOTE: Only parts shown in black are included with this package. Parts shown in blue are included with the UC7™ Boom Height Control System. Connect cable C42 to the 6‐pin display bus connector on the HCM1 (Figure 4). Display Bus Figure 4: Display Bus Location Connect cable C42 to cable C43 with a 2‐way coupler with terminator (E20). The 2‐way coupler with terminator is WHITE. Route cable C43 into the cab. Connect to the 3‐way coupler (E10). Visit www.solutions.norac.ca for more system Page 6 installation and troubleshooting info. ...
Page 10
WWW.NORAC.CA PRECISION DEFINED Connect the power cable (C30) to the 3‐way coupler (E10). Connect the two cables C42 together with a 2‐way coupler with terminator (E20). Connect one end to the 3‐way coupler (E10). Connect the other end to the CANbus Repeater (E08). Connect cable C40 (Installation without an Apollo) or cable C41 (Installation with an Apollo) to the CANbus Repeater (E08). Visit www.solutions.norac.ca for more system Page 7 installation and troubleshooting info. ...
Page 11
WWW.NORAC.CA PRECISION DEFINED 3.4. Pull Type Display Cabling Installation If installing on a pull type machine, the parts listed in Section 1.2 are needed and must be ordered separately from this kit. Cable C43 is not used for this type of installation. Figure 5: Display Cabling Overview NOTE: Only parts shown in black are included with this package. Parts shown in blue are included with the UC7™ Boom Height Control System. Connect cable C42 to the 6‐pin display bus connector on the HCM1 (Figure 6). Visit www.solutions.norac.ca for more system Page 8 installation and troubleshooting info. ...
Page 12
WWW.NORAC.CA PRECISION DEFINED Display Bus Figure 6: Display Bus Location Connect cable C45 to cable C42 with a 2‐way coupler with terminator (E20). The 2‐way coupler with terminator is WHITE. Route cable C45 to the hitch. Connect cable C45 to cable C44 with a 2‐way coupler (E12). The 2‐way coupler is BLACK. The 2‐way coupler (E12) will provide the hitch disconnect. Route cable C44 into the cab. Connect to the 3‐way coupler (E10). Connect the power cable (C30) to the 3‐way coupler (E10). Connect the two cables C42 together with a 2‐way coupler with terminator (E20). Connect one end to the 3‐way coupler (E10). Connect the other end to the CANbus Repeater (E08). Connect cable C40 (Installation without an Apollo) or cable C41 (Installation with an Apollo) to the CANbus Repeater (E08). Visit www.solutions.norac.ca for more system Page 9 ...
Page 13
WWW.NORAC.CA PRECISION DEFINED 3.5. Switchbox Installation Disconnect cable C20 from the HCM1 module (E01). Insert the 12‐pin tee on cable C26 between the HCM1 module and cable C20. Route the other end of cable 26 to the cab of the sprayer. Install the switchbox (C25) inside the cab. Connect the switchbox to cable C26. If cable C26 is not long enough, a network cable and coupler are available for order from NORAC. Item Part Number Name C27 43220‐03 CABLE NETWORK 14 AWG 3M E12 43764 NETWORK COUPLER 2‐WAY Some sprayer types may not use all the switch functions. Figure 7: Switchbox Installation NOTE: Only parts shown in black are included with this package. Parts shown in blue are included with the UC7™ Boom Height Control System. ...
WWW.NORAC.CA PRECISION DEFINED 4 Cable Schematics 4.1. Item C25: 50250 – Switchbox Visit www.solutions.norac.ca for more system Page 11 installation and troubleshooting info. ...
Page 15
WWW.NORAC.CA PRECISION DEFINED 4.2. Item C26: 50140‐11 – Cable Switchbox Tee ‐ 50250 Visit www.solutions.norac.ca for more system Page 12 installation and troubleshooting info. ...
Page 16
WWW.NORAC.CA PRECISION DEFINED 4.3. Item C40: 1015764‐01 – Cable Topcon X25, X30 Cab Interface Visit www.solutions.norac.ca for more system Page 13 installation and troubleshooting info. ...
Page 17
WWW.NORAC.CA PRECISION DEFINED 4.4. Item C41: 1015765‐01 – Cable Topcon CM‐40 Interface Visit www.solutions.norac.ca for more system Page 14 installation and troubleshooting info. ...
Page 18
WWW.NORAC.CA PRECISION DEFINED 4.5. Item C42: 43220‐0.5 ‐ Cable Network 14 AWG – 0.5m Visit www.solutions.norac.ca for more system Page 15 installation and troubleshooting info. ...
Page 19
WWW.NORAC.CA PRECISION DEFINED 4.6. Item C43: 43220‐10 ‐ Cable Network 14 AWG – 10m Visit www.solutions.norac.ca for more system Page 16 installation and troubleshooting info. ...
Page 20
WWW.NORAC.CA PRECISION DEFINED 4.7. Item C44: 43220‐03 ‐ Cable Network 14 AWG – 3m Visit www.solutions.norac.ca for more system Page 17 installation and troubleshooting info. ...
Page 21
WWW.NORAC.CA PRECISION DEFINED 4.8. Item C45: 43210‐15 ‐ Cable Network 18 AWG – 15m Visit www.solutions.norac.ca for more system Page 18 installation and troubleshooting info. ...
Page 22
WWW.NORAC.CA PRECISION DEFINED Notes Visit www.solutions.norac.ca for more system Page 19 installation and troubleshooting info. ...
Page 23
TOPCON Agriculture Canada 3702 Kinnear Place Saskatoon, SK S7P 0A6 TOPCON Agriculture Americas W5527 Hwy 106 Fort Atkinson, WI 53538 TOPCON Precision Agriculture Europe Avenida de la industria, 35, Tres Cantos, España Spain Support Phone: 888 979 9509 E‐mail: tasupportn@topcon.com Web: www.norac.ca ...
Need help?
Do you have a question about the Topcon X25 and is the answer not in the manual?