These instructions are written to be used by an experienced mason or builder who is familiar with applicable codes concerning the
construction of masonry fireplaces.
Step 1:
extend beyond the Circulator at the sides and back and be at least flush with the front of the Circulator. If the
fireplace is to have an ash pit, the ash dump should be put in at the time of the firebrick base is laid. Do not lay
firebrick up into the metal firebox of the Circulator. (See Figure 1.)
Fig 1: Hearth Plan at
Floor Level
Step 2:
of the unit. Cover the unit with a single thickness of insulation, taking particular care at corners. A thin watery
mixture of mortar brushed on the steel Circulator will help to hold the insulation in place. At this point if
particular care is given to the glass wool insulation, location of the cold air intake grille, and gauging of the
masonry work, the rest of the installation will be made much easier. (See Figure 2.)
Fig 2: Unit in Position
Step 3:
and grille locations. Take care to prevent the masonry from touching the unit at any point. The finished width
of the fireplace opening should be 1" to 2" less than the width of the Circulator opening. Lay the masonry
beyond the Circulator on each side of the Circulator opening, making a concealed joint between the Circulator
Fig 3: Insulation & Concealed
and the masonry. Due to heat expansion, mortar will not stay in this concealed joint. (See Figure 3.)
Joint
Step 4:
outlet. The air must be circulated through the unit. Air passages should be finished smoothly to speed air flow
and prevent heat loss.
The "Vestalaire Universal Grille and Duct" system will simplify planning and installation of air intakes and outlets.
If electric fan grilles are to be used in the Circulator, and the power line to the fan is concealed, it may be
desirable to locate the conduit and junction box in the masonry. When fans are used, two fans–one located in
Fig 4: Brick Work & Grille
each cold air intake–are needed. Never locate the fans in the warm air outlet. Set the cold air intake grilles in
Location
place. Do not remove top grille face until the boxes are installed in the masonry. This assures a neat and level

Important Installation Instructions for Mason or Builder

Finish the foundation with a layer of firebrick upon which to set the Circulator Unit. The firebrick should
Position the Circulator on the firebrick hearth. Unpack glass wool insulation and apply around the bottom
Lay the first course of masonry dry around the unit to check dimensions, thickness of mortar joints
Plan the location of the cold air intake grilles. Air must not pass direct from the cold air inlet to the hot air

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vestal Aire 9 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vestal Vestal Aire 9

  • Page 1 Important Installation Instructions for Mason or Builder These instructions are written to be used by an experienced mason or builder who is familiar with applicable codes concerning the construction of masonry fireplaces. Step 1: Finish the foundation with a layer of firebrick upon which to set the Circulator Unit. The firebrick should extend beyond the Circulator at the sides and back and be at least flush with the front of the Circulator.
  • Page 2 If after years of usage it should become necessary to clean out the chimney flue and smoke shelf, the valve plate of the Vestal Circulator can be removed. Remove the poker control handle by taking loose bolts “A: and “B.” Slide the valve plate to the left until it stops, then push the right end of the valve plate to the back of the unit until it is free of its hinges.
  • Page 3 Intake And Outlet Grilles Openings in the masonry are skillfully hidden by the decorative grilles on the cool air intakes and warm air outlets of the Vestal Fireplace. They blend perfectly with any style mantel, and can be painted to match the surrounding walls or masonry. A metal housing is set permanently in the masonry or wall to which the grille face is attached.
  • Page 4 Therefore, due to the unlimited variety of applications for the Vestal Circulator Fireplace Unit, it is impossible to give specific details that cover all installations and dimensions of the foundation.
  • Page 5 Air passage must be provided through this circulator. Failure to do so will void the warranty and damage the unit as well as possibly create a fire hazard. This is not a zero clearance fireplace. It must be installed within a masonry fireplace and chimney structure that meets applicable codes. Source: Vestal Manufacturing, PO Box 420 Sweetwater,Tennessee 37874...

This manual is also suitable for:

Vestal aire 176Vestal aire 30Vestal aire 34Vestal aire 38Vestal aire 42Vestal aire 50

Table of Contents