(1) year from the date of shipment. If any of the goods are found by the seller to be defective, such goods will be replaced or repaired at the seller's cost. Refer to the Clark-Reliance Terms & Conditions for full warranty details.
Page 7
2. Remove the inlet gland, and inlet gland spiral wound gasket. Inlet Gland Spiral Wound Gasket 3. Remove Disc Spring, and Downstream Seat. Disc Spring Downstream Seat 16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.Jerguson.com ● sales@clark-reliance.com...
Page 8
7. Remove gland follower by taking off the four nuts shown in the picture below, also remove the gland ring. Pull out the -3- stem packing rings packing rings and discard. Discarded Packing Gland Ring 16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.Jerguson.com ● sales@clark-reliance.com...
Page 9
Third ring should be about flush with top of valve face. 16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.Jerguson.com ● sales@clark-reliance.com...
Page 10
Retainer Clip (Handle In Run Position) 16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.Jerguson.com ● sales@clark-reliance.com...
Page 11
500 Ft-Lbs. Install anti-rotation pin to lock nut in place. The valve is now ready to be hydro-tested. 16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.Jerguson.com ● sales@clark-reliance.com...
Page 12
IOM J500.36 ® Jerguson 360 Series 2017.10 16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.Jerguson.com ● sales@clark-reliance.com...