Do you have a question about the SFAR-1M-2DI2DO and is the answer not in the manual?
Questions and answers
Summary of Contents for GC5 SFAR-1M-2DI2DO
Page 1
SFAR-1M-2DI2DO User Manual Expansion Module – 2 Digital Inputs, 2 Digital Outputs Global Control 5 Sp. z o.o. Warsaw, Poland www.gc5.pl Version 3.0 Page 1 / 13...
Configuration registers ..................8 3.4.3. Watchdog information ..................8 5.1. Block diagram ........................9 5.2. Connection of outputs ....................10 5.3. Connection of inputs...................... 10 6.1. Registered access ......................10 6.2. Bit access ......................... 12 Version 3.0 www.gc5.pl Page 2 / 13...
Page 3
We reserve the right to change product specifications without notice. Please read the instructions carefully and follow the recommendations concluded therein. WARNING! Failure to follow instructions can result in equipment damage or impede the use of the hardware or software. Version 3.0 www.gc5.pl Page 3 / 13...
The module is equipped with a set of LEDs to indicate the status of inputs and outputs which is useful for diagnostic purposes and helping to find errors. Module configuration is done via USB by using a dedicated computer program. You can also change the parameters using the Modbus protocol. Version 3.0 www.gc5.pl Page 4 / 13...
Height 90 mm Size Length 56,4 mm Width 17,5 mm Interface RS485 Up to 128 devices Table 1 - Technical specifications Power consumption with active Modbus transmission and high state on all inputs Version 3.0 www.gc5.pl Page 5 / 13...
These protective steps include control cabinet grounding, module grounding, cable shield grounding, protective elements for electromagnetic switching devices, correct wiring as well as consideration of cable types and their cross sections. Version 3.0 www.gc5.pl Page 6 / 13...
Output states must be set to the appropriate state in order to reassure the safety of persons or property. The default value is 0 milliseconds which means the watchdog function is disabled. Version 3.0 www.gc5.pl Page 8 / 13...
LED indicates that on the input is high state. DO1, DO2 LED indicates that the output is on. Table 5 - Description of indicators Module Connection 5.1. Block diagram Picture 3 - Block diagram Version 3.0 www.gc5.pl Page 9 / 13...
34 0x22 Incorrect packets MSB Read & Write No of received packets with error 40036 35 0x23 Incorrect packets LSB Read & Write 40037 36 0x24 Sent packets MSB Read & Write No of sent packets Version 3.0 www.gc5.pl Page 10 / 13...
Capture counter 2 1169 1168 0x490 Captured 1 Read & Write Captured value of counter 1 1170 1169 0x491 Captured 2 Read & Write Captured value of counter 2 Table 7 - Bit access Version 3.0 www.gc5.pl Page 12 / 13...
Page 13
Communication with the module happens via the USB cable. The module does not require any drivers. Picture 6 - Configuration process Configurator is an universal software, whereby it is possible to configure all available modules. Picture 7 - Configurator Version 3.0 www.gc5.pl Page 13 / 13...