INSTALLATION INSTRUCTIONS CONFORMITY TO REGULATIONS AND LAWS The appliance is to be installed by an authorised person in accordance with AS5601 - the installer must ensure the installation complies with all regulatory and manufacturer requirements and operationally and functionally test, make necessary adjustments and commission the appliance as part of installation.
Page 4
• Switch on the appliance following the instructions for use. Test burners ignition and flame uniformity. Also check the appliance for gas leaks and make sure the gas exhaust system functions correctly. • If necessary, consult the “Troubleshooting guide” below. Testing the gas nominal thermal power •...
The pilot burner is difficult or impossible to ignite Beware of the appliance’s hot surfaces! • Gas supply pressure low. This appliance is designed for professional use and must only • Gas pipe or injector clogged. be used by trained personnel. It is exclusively designed to •...
Page 6
seconds, then release it. If the pilot flame goes out, repeat the • clean and rinse the oven interior with a sponge using tepid operation. soapy water and/or normal liquid detergents, drying The pilot can be seen and if necessary lit throught the hole in afterwards.
Page 7
Appendix TECHNICAL DATA NATURAL T1 - INJIECTOR OREFICES SIZES PROPANE MAIN 2.10 1.30 PILOT MARKING Ø 110 OPEN BURNER 1.00 0.70 TURNDOWN SCREW Fully in Fully in MAIN 2.55 1.55 OVEN BURNER PILOT MARKING TURNDOWN SCREW NATURAL T2 - AERATION SHUTTERS SETTING PROPANE Ø...
APPENDICE - ANHANG -APPENDIX - APPENDICE - APÉNDICE - AANHANGSEL SERIE 70 Mod. AC7-..., AC7FG-..., AC7FE-... INSTALLATION DIAGRAM Measurements in cm G - Gas connection ISO 7/1 R3/4 E - Electric cable stress relief (CR0500390) 8/9...
Page 9
APPENDICE - ANHANG -APPENDIX - APPENDICE - APÉNDICE - AANHANGSEL SERIE 70 Mod. ABF7-8G INSTALLATION DIAGRAM Measurements in cm G- Gas connection ISO 7/1 R3/4 (CR0500390) 9/9...
Need help?
Do you have a question about the 70 Series and is the answer not in the manual?
Questions and answers