6. TROUBLESHOOTING
Problem
Jack will not lift
Overloaded
load
Oil level low
Release valve not correctly closed
Air in system
Packing worn or defective
Jack does not lift
Oil level low
high enough or
feels 'spongy'
Worn seals
Air in system
Release valve not closed
Jack lifts but will
Release valve partially open
not hold load
Air in system
Faulty seals
Jack will not lower
Ram damaged
completely
Air in system
Release valve partially open
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
Possible cause
Be sure to use jack with adequate capacity.
Top up oil level.
Check and close release valve.
Open release valve and air vent (if fitted) and pump the
handle a few times. Close valve and re-try.
Return jack to local service agent.
Top up oil level. Check and fully open release valve.
Return jack to local service agent.
Open release valve and air vent (if fitted) and pump the
handle a few times. Close valve and re-try.
Check and close release valve.
Check and close release valve.
Open release valve and air vent (if fitted) and pump the handle
a few times. Close valve and re-try.
Return jack to local service agent.
Contact local service agent
Open release valve and air vent (if fitted) and pump the handle
a few times. Close valve and re-try
Check and fully open release valve.
01284 703534