Angekis U3-5FHD6 User Manual

Usb3.0 hd video camera

Advertisement

Quick Links

USB3.0 HD Video Camera
User manual
Model: Angekis U3-5FHD6
Wide Angle Conference Room Camera
Version V1.0
(English)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the U3-5FHD6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Angekis U3-5FHD6

  • Page 1 USB3.0 HD Video Camera User manual Model: Angekis U3-5FHD6 Wide Angle Conference Room Camera Version V1.0 (English)
  • Page 2: Table Of Contents

    CONTENT SAFETY GUIDES....................2 ACCESSORIES....................5 QUICK START.....................5 PRODUCT HIGHLIGHTS..................5 PRODUCT SPEC....................6 CAMERA INTERFACE..................7 CAMERA DIMENSION..................7 IR REMOTE CONTROLLER..................8 VISCA IN ( RS232 PORT )................. 10 VISCA PROTOCOL....................11 PELCO-D PROTOCOL ..................18 PELCO-P PROTOCOL ..................19 OSD MENU......................20 IR TRANSFER (IR PASS)&UVC CONTROL............
  • Page 3: Safety Guides

    SAFETY GUIDES 1.Before operation, please fully read and follow all instructions in the manual. For your safety, always keep this manual with the camera. 2.The camera power input range is 100-240VAC(50-60Hz),ensure the power supply input within this rate before powering on. 3.The camera power voltage is 12VDC, rated currency is 2A.
  • Page 4 DO NOT use hands for catching; or moving the camera barrel, otherwise it may damage the camera mechanical structure DO NOT use hands to quick rotate the camera barrel, otherwise it maydamage the camera mechanical structure, even break the motor driving.
  • Page 5: Accessories

    ACCESSORIES Check all bellow items when open the package: Camera······················································································1 PCS Power Adapter·············································································1 PCS Power Cable················································································ 1 PCS RS232 Control Cable······································································ 1 PCS USB3.0 Cable··············································································· 1 PCS Remote Controller·········································································1 PCS User Manual··············································································· 1 PCS Double-sided Adhesive··································································· 1 PCS QC certification············································································ 1 PCS QUICK START Check all cable connections before power on.
  • Page 6: Product Highlights

    2.DIP Switch Setting(at the bottom of the camera): Dial Switch(ARM) SW-1 SW-2 Instruction Updating mode Debugging mode Working mode Dial Switch(USB) SW-5 SW-6 Instruction Updating mode Debugging mode Undefined Undefined PRODUCT HIGHLIGHTS  3 cables in 1 design: video, control & power and be transited via signal USB3.0 cable. (Notice: to achieve stable power supply via USB3.0 cable, we suggest only use the 3m USB3.0 cable supplied by the factory, and the PC’s USB 3.0 port can supply more than 5V 1000mA power;...
  • Page 7: Product Spec

    TECHNICAL SPEC 1080P60/50/30/25, 720P60/50/30/25, USB3.0 1024x576@30,960x540@30,640x360@30,352x288@30 Video Format USB2.0 1024x576@30,960x540@30,640x360@30,352x288@30 Video Port USB3.0, USB2.0 Sensor 1/2.8 inch high quality 5MP CMOS sensor Lens F3.1 ~ 15.5mm(5X), F1.8 – 2.8, Field of view:90°(wide)-20°(tele) Pan: ±170° ; Pan/tilt Rotation Tilt: -30° ~ +90°, support up-side down installation Pan/tilt Speed Pan: 0.1°~120°/s ;...
  • Page 8: Camera Interface

    Dimension 220mm×190mm×173mm Net Weight 1.25KG ( 2.8LBS ) CAMERA INTERFACE 1.Camera Lens 6. Tripod Screw Hole 10. RS232 (VISCA IN) Port 2.Camera Base 7. Installation Hole 11.USB 3.0 Port 3.IR Receiver Panel 8. Power Indicator light(red) 4.Indicator Light 9. 12V DC Power Input 5.Dial Switch CAMERA DIMENSION...
  • Page 9: Ir Remote Controller

    IR REMOTE CONTROLLER · Video mute Short press Video mute button to turn off the camera and short press again to turn on. Power Key Under normal working mode, short press POWER key to enter standby mode;Press it again, the camera will do self-configuration, then go back to HOME position.It will go to preset position if power on model has been set before.
  • Page 10 F+/F-: Set focus by manual, only valid under manual focus mode T/W: Set the lens zoom rate. Navigate Key: Up/Down/Left/Right Under normal working mode, use navigate key to set the pan tilt, and select values when enter OSD Home Key: Under normal working mode, short press Home key to let the camera go back to home position.
  • Page 11: Visca In (Rs232 Port

    VISCA IN (RS232 PORT) Function IR OUT Camera VISCA IN Windows DB-9 Camera VISCA IN RS485 A(+) A(+) A(+) IR OUT IR OUT B(-) B(-) B(-) SERIAL PORT CONFIGURATION: Parameter Value Parameter Value Baud rate 2400/4800/9600/11520 Stop Bit 1 bit Start Bit 1 bit Verify Bit...
  • Page 12: Visca Protocol

    VISCA PROTOCOL Part1 Camera Return Command Ack/Completion Message Command Packet Note z0 41 FF Returned when the command is accepted. Completion z0 51 FF Returned when the command has been executed. z = camera adderss+8 Error Messages Command Note Packet Returned when the command format is different or when a command with Syntax Error z0 60 02 FF...
  • Page 13 Command type function Command packet Note 8x 01 04 35 04 FF Manual 8x 01 04 35 05 FF Sodium lamp 8x 01 04 35 08 FF fluorescent 8x 01 04 35 09 FF Reset 8x 01 04 03 00 FF 8x 01 04 03 02 FF Manual Control of R Gain CAM_RGain...
  • Page 14 Command type function Command packet Note 8x 01 04 0C 00 00 0p 0q Direct pq: Gain Positon (0~0x0E) Reset 8x 01 04 0D 00 FF 8x 01 04 0D 02 FF Bright Setting CAM_Bright Down 8x 01 04 0D 03 FF 8x 01 04 4D 00 00 0p 0q Direct pq: Bright l Positon...
  • Page 15 Command type function Command packet Note 8x 01 04 A2 00 00 0p 0q CAM_Contrast Direct (0~0x0F) CAM_Gamma Direct 81 01 04 5B 0p FF (0~0x04) 50HZ 81 01 04 23 01 FF FLICK 60HZ 81 01 04 23 02 FF 81 01 04 23 00 FF Menu On 8x 01 06 06 02 FF...
  • Page 16 Command type function Command packet Note Reset 8x 01 06 05 FF 8x 01 06 07 00 0W W:1 UpRight 0:DownLeft 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF Pan-tiltLimitSet YYYY: Pan Limit Position(TBD) 8x 01 06 07 01 0W ZZZZ: Tilt Limit Position(TBD) Clear 07 0F 0F 0F 07 0F 0F 0F FF...
  • Page 17 y0 50 02 FF IR_Transfer 8x 09 06 1A FF y0 50 03 FF y0 50 02 FF IR_Receive 8x 09 06 08 FF y0 50 03 FF y0 07 7D 01 04 00 FF Power ON/OFF y0 07 7D 01 04 07 FF Zoom tele/wide y0 07 7D 01 04 38 FF AF On/Off...
  • Page 18 1/15 1/12 16dB 18dB 20dB 22dB Gain Gain 24dB 10dB 26dB 12dB 28dB 14dB 30dB IRIS GAIN F1.8 +28dB F1.8 +26dB F1.8 +24dB F1.8 +22dB F1.8 +20dB F1.8 +18dB F1.8 +16dB F1.8 +14dB F1.8 +12dB F1.8 +10dB F1.8 +8dB F1.8 +6dB F1.8 +4dB...
  • Page 19: Pelco-D Protocol

    PELCO-D PROTOCOL Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 0xFF Address 0x00 0x08 Pan Speed Tilt Speed Down 0xFF Address 0x00 0x10 Pan Speed Tilt Speed Left 0xFF Address 0x00 0x04 Pan Speed Tilt Speed Right 0xFF Address 0x00 0x02 Pan Speed Tilt Speed...
  • Page 20: Pelco-P Protocol

    PELCO-P PROTOCOL Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8 0xA0 Address 0x00 0x08 Pan Speed Tilt Speed 0xAF Down 0xA0 Address 0x00 0x10 Pan Speed Tilt Speed 0xAF Left 0xA0 Address 0x00 0x04 Pan Speed Tilt Speed 0xAF Right 0xA0 Address...
  • Page 21: Osd Menu

    OSD MENU 1. Under working mode, press the menu button on the IR remote controller, to enter the OSD menu: 2, Use the navigate button to select the main menu. Once been selected, the main menu will change to blue background, and the right side will show all sub menu options.
  • Page 22 FOCUS MODE AUTO/MANUAL/PUSH Default:AUTO FOCUS LIMIT Focus Distance between camera and object: Default:1.5M 1.5M/2M/3M/6M/10M FOCUS DZOOM DIGITAL ZOOM: ON/OFF Default:OFF RATIO DIS Zoom Rate Display (include Digital Zoom):ON/OFF Default:OFF RETURN RETURN to Main menu EXP.MODE AUTO、MANUAL、BRIGHT、SHUTTER、IRIS Default:AUTO Shutter speed:1/8~1/10000, only valid when EXP Default:1/100 SHUTTER MODE set to MANUAL or SHUTTER mode...
  • Page 23 RETURN Return to Main Menu 2D NR 2D Noise Reduction: OFF/ON Default:OFF 3D NR 3D Noise Reduction: OFF/ON Default:AUTO SHARPNESS Sharpness setting: OFF/0~15 Default:OFF CONTRAST Contrast setting: 0~15 Default:8 QUALITY SATURATION Color Saturation Setting: 0~15 Default:8 BRIGHT Brightness setting: 0~15 Default:6 D_WDR White Dynamic Rate: OFF/ 1~6...
  • Page 24: Ir Transfer (Ir Pass)&Uvc Control

    IR TRANSFER(IR PASS) 1.Currently the camera support NEC code format. For customized with other codes, pls contact us. 2.Once the camera finish power configuration, enable the IR transfer function via sending COM command. 3.Get the targeted remote controller point to the camera IR receiver, press keys on the remote controller, then the camera will output the received IR code via VISCA IN port.
  • Page 25 CT_ZOOM_ABSOLUTE_CONTROL 8x 01 04 47 0p 0q 0r 0s FF CT_PANTILT_ABSOLUTE_CONTROL 8x 01 06 02 VV WW 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z F CT_PANTILT_RELATIVE_CONTROL 8x 01 06 01 pp qq rr ss FF CT_ZOOM_RELATIVE_CONTROL 8x 01 04 07 pp FF...