CONTENT SAFETY GUIDES....................2 ACCESSORIES....................5 QUICK START.....................5 PRODUCT HIGHLIGHTS..................5 PRODUCT SPEC....................6 CAMERA INTERFACE..................7 CAMERA DIMENSION..................7 IR REMOTE CONTROLLER..................8 VISCA IN ( RS232 PORT )................. 10 VISCA PROTOCOL....................11 PELCO-D PROTOCOL ..................18 PELCO-P PROTOCOL ..................19 OSD MENU......................20 IR TRANSFER (IR PASS)&UVC CONTROL............
SAFETY GUIDES 1.Before operation, please fully read and follow all instructions in the manual. For your safety, always keep this manual with the camera. 2.The camera power input range is 100-240VAC(50-60Hz),ensure the power supply input within this rate before powering on. 3.The camera power voltage is 12VDC, rated currency is 2A.
Page 4
DO NOT use hands for catching; or moving the camera barrel, otherwise it may damage the camera mechanical structure DO NOT use hands to quick rotate the camera barrel, otherwise it maydamage the camera mechanical structure, even break the motor driving.
ACCESSORIES Check all bellow items when open the package: Camera······················································································1 PCS Power Adapter·············································································1 PCS Power Cable················································································ 1 PCS RS232 Control Cable······································································ 1 PCS USB3.0 Cable··············································································· 1 PCS Remote Controller·········································································1 PCS User Manual··············································································· 1 PCS Double-sided Adhesive··································································· 1 PCS QC certification············································································ 1 PCS QUICK START Check all cable connections before power on.
2.DIP Switch Setting(at the bottom of the camera): Dial Switch(ARM) SW-1 SW-2 Instruction Updating mode Debugging mode Working mode Dial Switch(USB) SW-5 SW-6 Instruction Updating mode Debugging mode Undefined Undefined PRODUCT HIGHLIGHTS 3 cables in 1 design: video, control & power and be transited via signal USB3.0 cable. (Notice: to achieve stable power supply via USB3.0 cable, we suggest only use the 3m USB3.0 cable supplied by the factory, and the PC’s USB 3.0 port can supply more than 5V 1000mA power;...
TECHNICAL SPEC 1080P60/50/30/25, 720P60/50/30/25, USB3.0 1024x576@30,960x540@30,640x360@30,352x288@30 Video Format USB2.0 1024x576@30,960x540@30,640x360@30,352x288@30 Video Port USB3.0, USB2.0 Sensor 1/2.8 inch high quality 5MP CMOS sensor Lens F3.1 ~ 15.5mm(5X), F1.8 – 2.8, Field of view:90°(wide)-20°(tele) Pan: ±170° ; Pan/tilt Rotation Tilt: -30° ~ +90°, support up-side down installation Pan/tilt Speed Pan: 0.1°~120°/s ;...
IR REMOTE CONTROLLER · Video mute Short press Video mute button to turn off the camera and short press again to turn on. Power Key Under normal working mode, short press POWER key to enter standby mode;Press it again, the camera will do self-configuration, then go back to HOME position.It will go to preset position if power on model has been set before.
Page 10
F+/F-: Set focus by manual, only valid under manual focus mode T/W: Set the lens zoom rate. Navigate Key: Up/Down/Left/Right Under normal working mode, use navigate key to set the pan tilt, and select values when enter OSD Home Key: Under normal working mode, short press Home key to let the camera go back to home position.
VISCA IN (RS232 PORT) Function IR OUT Camera VISCA IN Windows DB-9 Camera VISCA IN RS485 A(+) A(+) A(+) IR OUT IR OUT B(-) B(-) B(-) SERIAL PORT CONFIGURATION: Parameter Value Parameter Value Baud rate 2400/4800/9600/11520 Stop Bit 1 bit Start Bit 1 bit Verify Bit...
VISCA PROTOCOL Part1 Camera Return Command Ack/Completion Message Command Packet Note z0 41 FF Returned when the command is accepted. Completion z0 51 FF Returned when the command has been executed. z = camera adderss+8 Error Messages Command Note Packet Returned when the command format is different or when a command with Syntax Error z0 60 02 FF...
Page 13
Command type function Command packet Note 8x 01 04 35 04 FF Manual 8x 01 04 35 05 FF Sodium lamp 8x 01 04 35 08 FF fluorescent 8x 01 04 35 09 FF Reset 8x 01 04 03 00 FF 8x 01 04 03 02 FF Manual Control of R Gain CAM_RGain...
Page 14
Command type function Command packet Note 8x 01 04 0C 00 00 0p 0q Direct pq: Gain Positon (0~0x0E) Reset 8x 01 04 0D 00 FF 8x 01 04 0D 02 FF Bright Setting CAM_Bright Down 8x 01 04 0D 03 FF 8x 01 04 4D 00 00 0p 0q Direct pq: Bright l Positon...
Page 15
Command type function Command packet Note 8x 01 04 A2 00 00 0p 0q CAM_Contrast Direct (0~0x0F) CAM_Gamma Direct 81 01 04 5B 0p FF (0~0x04) 50HZ 81 01 04 23 01 FF FLICK 60HZ 81 01 04 23 02 FF 81 01 04 23 00 FF Menu On 8x 01 06 06 02 FF...
OSD MENU 1. Under working mode, press the menu button on the IR remote controller, to enter the OSD menu: 2, Use the navigate button to select the main menu. Once been selected, the main menu will change to blue background, and the right side will show all sub menu options.
Page 22
FOCUS MODE AUTO/MANUAL/PUSH Default:AUTO FOCUS LIMIT Focus Distance between camera and object: Default:1.5M 1.5M/2M/3M/6M/10M FOCUS DZOOM DIGITAL ZOOM: ON/OFF Default:OFF RATIO DIS Zoom Rate Display (include Digital Zoom):ON/OFF Default:OFF RETURN RETURN to Main menu EXP.MODE AUTO、MANUAL、BRIGHT、SHUTTER、IRIS Default:AUTO Shutter speed:1/8~1/10000, only valid when EXP Default:1/100 SHUTTER MODE set to MANUAL or SHUTTER mode...
Page 23
RETURN Return to Main Menu 2D NR 2D Noise Reduction: OFF/ON Default:OFF 3D NR 3D Noise Reduction: OFF/ON Default:AUTO SHARPNESS Sharpness setting: OFF/0~15 Default:OFF CONTRAST Contrast setting: 0~15 Default:8 QUALITY SATURATION Color Saturation Setting: 0~15 Default:8 BRIGHT Brightness setting: 0~15 Default:6 D_WDR White Dynamic Rate: OFF/ 1~6...
IR TRANSFER(IR PASS) 1.Currently the camera support NEC code format. For customized with other codes, pls contact us. 2.Once the camera finish power configuration, enable the IR transfer function via sending COM command. 3.Get the targeted remote controller point to the camera IR receiver, press keys on the remote controller, then the camera will output the received IR code via VISCA IN port.