Advertisement

Quick Links

Instruction Manual
Air Purifier NERIOX Model:P8802
This manual only applies to P8802 model, please read carefully before use. This manual is part of the
product. It contains important instructions for commissioning and operation. Observe them, even if you pass
Therefore, keep these operating instructions in a safe place.
Brütsch/Rüegger Tools Ltd.
Heinrich Stutz-Strasse 20
P.O. Box
8902 Urdorf
Switzerland
Phone +41447366363
info@brw.ch
www.brw.ch
on the product to a third party.
Brütsch/Rüegger Tools GmbH Deutschland
Edisonstrasse 7 – 11
68309 Mannheim
Deutschland
Phone +49621720060
info@brw-tools.de
www.brw-tools.de
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NERIOX P8802 and is the answer not in the manual?

Questions and answers

Summary of Contents for Brütsch Rüegger NERIOX P8802

  • Page 1 Instruction Manual Air Purifier NERIOX Model:P8802 This manual only applies to P8802 model, please read carefully before use. This manual is part of the product. It contains important instructions for commissioning and operation. Observe them, even if you pass on the product to a third party. Therefore, keep these operating instructions in a safe place.
  • Page 2: Table Of Contents

    Table of content 1. Description ........................3 2. Principles of Disinfection ....................6 3. Instructions Before Use ....................9 4. Instructions for Use ..................... 11 5. Maintenance ....................... 13 6. Safety Precautions ...................... 15 7. Important Matters ......................16 8. Storage Conditions ...................... 16 9.
  • Page 3: Description

    1. Description A: Air Outlet E: Air Inlet B: Control Panel F: Sensor C: Display Panel G: Power Cord D: Body H: Universal Wheel Brütsch/Rüegger Tools Ltd. Brütsch/Rüegger Tools GmbH Deutschland Heinrich Stutz-Strasse 20 Edisonstrasse 7 – 11 P.O. Box 68309 Mannheim 8902 Urdorf Deutschland...
  • Page 4 1: Power Button 6: Sleep Button 2: UVC Button 7: Timer Button 3: ANION Button (Option) 8: Filter Reset 4: WIFI Button 9: Air Quality Indicator 5: Wind Speed Adjustment Brütsch/Rüegger Tools Ltd. Brütsch/Rüegger Tools GmbH Deutschland Heinrich Stutz-Strasse 20 Edisonstrasse 7 –...
  • Page 5 1:Anion Function Indicator (Option) 5: WIFI Function Indicator 2: Child Lock Function Indicator 6: Digital Display 3: Sleep Function Indicator 7: UVC Disinfection Function Indicator 4: Filter Life 8: Wind Speed & Auto Speed Function Indicator Brütsch/Rüegger Tools Ltd. Brütsch/Rüegger Tools GmbH Deutschland Heinrich Stutz-Strasse 20 Edisonstrasse 7 –...
  • Page 6: Principles Of Disinfection

    2. Principles of Disinfection This air disinfection machine adopts H14 high-efficiency filter assembly and UVC LED ultraviolet module. H14 high-efficiency filter (according to EN 1822) can intercept 99.995% of aerosols and 0.1μm-0.3μm particles carrying bacterial pathogens and 0.1 μm - 10 μm particulate matters.
  • Page 7 Primary Filter ● Dust ● Hair UVC Disinfection ModuleVC Composite Filter Disinfection ● Volatile Organic Gases ● Bacteria (VOCs) ● Virus ● Odor Idea: An A-band indicator is integrated in ● Second-hand Smoke UVC, used to observe whether the lamp ●...
  • Page 8 PRE-FILTER The primary filtration uses an aluminum alloy filter located in the pre-filter. It is mainly used for filtering dust larger than 5 microns, including large dustparticles, dander, pollen, floating debris, and other pollutants. It can be washed many times and used repeatedly.
  • Page 9: Instructions Before Use

    3. Instructions Before Use Select the room where the air needs to be purified, and place the disinfection machine on a stable floor or table in the room. For free air circulation, avoid placing the disinfection machine behind curtains, under windows, near furniture or shelves, or near any obstacles position, at least 50cm of free space should be reserved on each side of the disinfection machine.
  • Page 10 Please also confirm:  The voltage at your home matches the voltage marked on the device;  Your device can be connected to an ungrounded power plug. This device is a Class II appliance  (Double insulation);  The air inlet and outlet are completely unobstructed; ...
  • Page 11: Instructions For Use

    4. Instructions for Use Power Switch Connect the power supply, the purifier can be turned on or off. Turn on the air quality detection sensor system of the disinfection machine. After the digital tube frame of the operation panel flashes for about 30 seconds, the air quality detection sensor system completes the detection.
  • Page 12 WIFI Function Long pressed "Wifi" for 5 seconds to start the network match. a. The WiFi indicator lights flash white when matching the network b. The WiFi indicator will be white when the matching is done c. Long press the "WiFi" key again for 5 seconds to reset the WiFi d.
  • Page 13: Maintenance

    Filter Reset When the service life of the machine filter expires, the filter life bar drops to the last grid and flashes, prompting to replace the filter; after the filter is replaced, long press this button and the filter life bar restores the full grid. The filter reset is successful. 5.
  • Page 14 Filter Replacement Filter Operating Frequency Operation Frequency Composite Filter Replace 10-12months This data is calculated based on the use of low-grade purification wind speed, using 8 hours a day; The recommended filter replacement frequency will vary depending on the duration of use and the working environment.
  • Page 15: Safety Precautions

    6. Safety Precautions  Please read this manual carefully before using the product, and keep this manual in a safe place. You need to read these instructions carefully and follow these suggestions:  For your safety, this product complies with applicable standards and regulations ...
  • Page 16: Important Matters

    7. Important Matters  Do not cover the air inlet or outlet.  Do not touch the appliance with wet hands.  Do not allow any liquid to enter the product.  Do not use this product in a humid place. ...
  • Page 17: Common Malfunctions

    9. Common Malfunctions Do not disassemble the machine without permission; improper repair may cause danger to the user! Before contacting the after-sales service center, please check the following troubleshooting table: Malfunction Examination Approach Can not start. Is the power plugged in? Plug in the power supply at the correct voltage.
  • Page 18: Product Configuration And Parameters

    10. Product Configuration and Parameters 695100.0100 Air Purifier Product Number: Product Name: P8802 NERIOX 50Hz 220V~ Rated Frequency: Rated Voltage: 35~64dB(A) Noise: Rated Power: 370*400*796mm Net Weight: 16kg Overall Size: 19kg Gross Weight: 150m² Application Area: Material: CADR 200m³/h CADR 900m³/h (Formaldehyde)...
  • Page 19: Intended Use

    11. Intended use This air purifier is used as a robust, compact and easy-to-operate. Any other use than that indicated is not approved! Modifications can cause this product to become damaged; this is also connected hazards such as short circuiting, fire, electric shock, etc. The manufacturer is not liable for any personal injury or material damage that arises from unintended use;...