Page 1
Mounting and operating instructions Safety clutch SI Responsible Mädler branches according to German Post Code Areas: For Switzerland: PCA 1, 2 and 3 PCA 0, 4 und 5 PCA 6, 7, 8 und 9 Mädler-Norm-Antrieb AG Subsidiary Subsidiary Headquarter Postbox 74 Mädler GmbH Mädler GmbH Mädler GmbH...
We do not take any warranty for resulting damages. To further develop the product we reserve the right for technical modifications. The Coupling SI described in here corresponds to the technical status at the time of printing of these mounting instructions.
Page 3
1: Coupling SI General mounting instructions • Please make sure the perfect technical condition of the Coupling SI overload system. • Before assembly and operation please check whether it is necessary to clean the components. • Lubricate the balls (e. g. Klüber-Microlube GL 263).
Page 4
Table of torque of engagement [Nm] The Coupling SI overload system is adjusted with the torques of engagement indicated in the table, if the customer does not indicate any other value. C A U T I O N ! The Coupling SI overload system must not exceed the max. torque of engagement!
Feather keyway: For the axial fixing of the Coupling SI overload system with cylindrical finish bore (standard: ISO fit - H7) and feather keyway (standard: DIN 6885, page 1 - JS9), there are the following possibilities.