Mounting Systems Tilt Kit Installation Guide Table of Contents Part I. Preparing…………………………………….………. 2-5 Part II. Feature of the Rail and the Module…………………5-7 Part III. Planning the array laylout………………...…………8-9 Part IV. Installation instruction………………………………. 9-15 Part V. Angle Adjustment Description………………………15-16 Part VI. Warranty…………………………………….. ……….17 Pub CM-V3.3 10 Mar 2012 Compliant Planning and Installation with Australia AS/NZS1170...
Solar Mounting Systems I. Preparing 1. Determine the wind region of your installation site Region Definition: Wind regions are pre defined for all of Australia by Australian Standard 1170. The Wind Region has nothing to do with surrounding topography or buildings. Most of Australia is designated Region A which indicates a Regional Ultimate Basic Wind Velocity of 45msec.
Page 3
2. Determine the installation area on the roof Chiko Mounting system may be installed anywhere on a roof but fixing centres are required to be reduced at ridges and edges. The diagram below shows the area of higher wind within a (minimum of 0.2a and 0.2b) of a roof edge or ridge (where b and d are the plan dimension of the building).
Page 4
Solar Mounting Systems 4. Determine the Maximum Rail Support Spacing Please use the following table to determine the base rail support spacing for Tilt kit installations to metal sheet roof. * Each row of solar panels shall have minimum of two rows of railing fixed to the roof framing. * The spacing of the rail fixing shall not exceed the recommended spacing, and shall be reduced to match the location of the roof rafter.
Page 5
35mm. The minimum embedment for each screw shall be 70mm. Timber with Joint Type classification J5 and J6 are excluded unless tested for Screw capacity. Please consult Chiko Solar for installing solar modules greater than length of 1960mm and weight of 27KG.
Module can be installed from the end to slide to the middle of the rail, also you can directly install from any part of the rail. This can effectively improve the installation efficiency. CK-FZ-R Installation CK-FA-R(CK-300N1) Installation...
Page 7
4. 35-50mm depth solar panel frame can be installed by CHIKO adjustable mid clamp and adjustable end clamp, more convenient, more strong.
Solar Mounting Systems 35mm depth 40mm depth 45mm depth 50mm depth III. Planning the array layout Planning the array layout 1.Array width = number of modules in horizontal direction x (solar module width + 11/16 in (18 mm)) +1-1/4 in (32 mm) 2.
Solar Mounting Systems 3.distance between front leg and back leg shall not exceed the distance given on table below Maximum distance (mm) between purlins supporting front and back leg Tilt Angle Region A&B Region C&D 1800 1400 1800 1200 1800 4.
Page 10
Solar Mounting Systems 3.Fix up the back leg, rubber pad to the roof by two 6.3*90 wood screws. 4.Fix up the rail to the back leg by the L-type module on the back leg. 5.As the requirement of Planning the array layout, Fix up front leg, back leg and rail on the roof. 6.Fix up the solar panel on the rail...
Page 11
Solar Mounting Systems 7. Install CHIKO normal mid clamp and end clamp (1) Fix up the solar panel on the rail by the end clamp, M8*25 hexagonal head screw and module. Fix up the Adjacent two solar panels on the rail by middle clamp and M8 Hexagon head screw (The length of the Hexagon head screw is according to the thickness of solar panel).
Page 12
Solar Mounting Systems 8 Install CHIKO adjustable mid clamp and adjustable end clamp Fix up the solar panel on the rail by the adjustable end clamp, M8*25 hexagonal head screw and module. Fix up the Adjacent two solar panels on the rail by adjustable middle clamp and M8 Hexagon...
Page 13
Solar Mounting Systems (2)The rest can be done in the same manner. Fix up all the solar panels on the rails.
Page 14
Solar Mounting Systems 9.Fix Tilt kit while connected with Chiko Tin roof clamp foot (kliplock 406 &700) will not cause any damages to tin roof, make the mount system more stonger.
Solar Mounting Systems V. Angle Adjustment Description Loose two M8 no head inner hex bolts on the back leg, adjust the length of back leg pipe, then fixup two M8 no head inner hex bolt to adjust the angle.
Page 16
Solar Mounting Systems Adjustable Angle mounting systems: there are three types according to the angle scope (1). 10-15Adjustable angle Mounting System (2)15-30Adjustable angle Mounting System (3)30-60Adjustable angle Mounting System...
Product that occurs during its shipment, storage, or installation. This Warranty shall be VOID if installation of the Product is not performed in accordance with Chiko Solar’s written installation instructions, or if the Product has been modified, repaired, or reworked in a manner not previously authorized by Chiko Solar IN WRITING, or if the Product is installed in an environment for which it was not designed.