INSTALLATION
•
This product must be installed in accordance with the IET Wiring Regulations
(BS7671) and the Building Regulations. If in any doubt, contact a qualified
electrician.
•
The recommended installation height (measured from air outlet to the floor) 1.2m
for men, 1.1m for women, and 0.9m for children.
•
The electrical connection must be made using a
double pole isolating switch with a break contact
distance of at least 3mm.
•
Remove the cover by removing the two socket hex screws on the bottom and after
pulling the cover forward disconnect the connecting wire for the sensor and the
ground lead.
•
Using the template, drill 4 off 8mm dia holes to a depth of 35mm having first
ensured the surface is suitable to support the weight of the dryer.
•
Feed the supply wiring through the access hole and cable clamp and fix the dryer
mechanism to the wall using the wall plugs and screws supplied.
•
Connect the mains supply wiring to the terminals at the lower left corner:
Red or brown wire to the terminal marked L
Black or blue wire to the terminal marked N
Green or green/yellow to the terminal marked E
•
Offer up the cover and reconnect the sensor wiring and ground lead then hook the
top edge into place and lower the cover until it sits fully into place.
•
Refit the two socket hex screws underneath.
APPLICATION
After finishing the installation, and switching on the power, and the hand dryer will
•
switch on automatically when hands are placed underneath the air outlet.
•
The hand dryer blows the hot air when hands are 11cm or closer to the air outlet,
and it stops working 1 second after removing hands. It will also stop working
automatically after 1 minute consecutive use. To restart the hand dryer, put hands
back underneath and the dryer will switch on again.
•
The sensitivity of the hand dryer is set at the highest value. If it operates for too long
or does not work after installation, please adjust the sensor.
Hexagon key
3