Cooper & Hunter HB16NK Owner's Manual

Cooper & Hunter HB16NK Owner's Manual

Hydro box of chv5 home

Advertisement

Quick Links

 Thank you for choosing Air Conditioners, please read this owner's manual carefully before operation and
retain it for future reference.If you have lost the Owner's Manual, please contact the local agent or visit
www.c ooperandhunter .com.
C ooper&Hunter reserves the right to interpret this manual which will be subject to any change due to
product improvement without further notice.
C ooper&Hunter , Inc. reserves the final right to interpret this manual.
Hydro Box of CHV5 Home
Owner's Manual
Hydrobox
Model:
HB16NK

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HB16NK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cooper & Hunter HB16NK

  • Page 1 Owner's Manual Hydrobox Model: HB16NK  Thank you for choosing Air Conditioners, please read this owner’s manual carefully before operation and retain it for future reference.If you have lost the Owner’s Manual, please contact the local agent or visit www.c ooperandhunter .com.
  • Page 2 User Notices Thank you for selecting C ooper&Hunter central air conditioner. The system consists of outdoor unit, hydro box, water tank, multi-split indoor units and related accessories. The functions of this system include cooling, heating, hot water generation, cooling & hot water generation, heating &...
  • Page 3: Table Of Contents

    Contents 1 PRODUCT DESCRIPTION AND CHARACTERISTICS ...................... 1 1.1 I ..............................1 NSTRUCTIONS TO SERS 1.2 S ................................1 AFETY OTICES 1.3 P ............................. 2 RODUCT HARACTERISTICS 2 UNIT STRUCTURE AND PERFORMANCE PARAMETERS ....................3 2.1 I ..........................3 NTERNAL TRUCTURE OF YDRO 2.2 E...
  • Page 4: Product Description And Characteristics

    Hydro Box of C H V5 Home Installation and Operation Manual 1 Product Description and Characteristics 1.1 Instructions to Users  Before carrying out any maintenance or repair of the water heater, please always disconnect the power supply and have the water heater adjusted and repaired by professional technicians. ...
  • Page 5: Product Characteristics

    Hydro Box of C H V5 Home Installation and Operation Manual  Do not place the gasoline or other flammable substances close to water heater; otherwise it may cause fire accident.  The water temperature displayed on the wired controller of water tank refers to the temperature around the measuring point.
  • Page 6: Unit Structure And Performance Parameters

    Hydro Box of C H V5 Home Installation and Operation Manual The unit uses pressure water tank and transfers the hot water by using the water pressure in tap water pipe. Therefore, it is not needed to add water pump or other associated accessories. This has simplified the installation procedures and saved the cost.
  • Page 7: Parameters Of Hydro Box

    Hydro Box of C H V5 Home Installation and Operation Manual 2.3 Parameters of Hydro Box Model HB16NK 4.5(3.6~16) Hot water heating capacity 105(75~140) Hot water yield ℃ Max outlet water temperautre Floor heating capacity Power of electric heater Power supply...
  • Page 8: Configuration Of Main Unit, Hydro Box And Water Tank

    Hydro Box of C H V5 Home Installation and Operation Manual 2.5 Configuration of Main Unit, Hydro Box and Water Tank Hydro box Recommended water Outdoor unit model Function remark model tank model WT2002FH3EK WT3002FH3EK Water tank can connect WT3502FH3EK solar heating system CHV-5SHH120NK WT4002FH3EK...
  • Page 9 Hydro Box of C H V5 Home Installation and Operation Manual D, please select straight solenoid water valve with small resistance(valve C and valve D aren’t included in H B 16N K ,please purchase in market). Meanwhile, valve C, valve D and floor heating performer shall select closed-type.
  • Page 10: Product Installation

    Hydro Box of C H V5 Home Installation and Operation Manual 3.2 Product Installation 3.2.1 Installation of Hydro Box Wall-mounted installation hole:...
  • Page 11 Hydro Box of C H V5 Home Installation and Operation Manual Installation steps:...
  • Page 12 Hydro Box of C H V5 Home Installation and Operation Manual 3.2.2 Requirements for Refrigerant Connection Pipe between Outdoor Unit and Hydro Outdoor unit and hydro box are connected through refrigerant pipe. Please refer to the instruction manual of outdoor unit.
  • Page 13 Hydro Box of C H V5 Home Installation and Operation Manual 3.2.3 Connection of Hot Water System Pipes Preparation of pipe: Hot water pipe must be used for circulating water inlet and outlet pipe. The PPR pipe with a nominal outer diameter of DN25 is recommended, while S2.5 series (wall thickness of 4.2mm) shall be used.
  • Page 14 Hydro Box of C H V5 Home Installation and Operation Manual (1) Installation diagram of hydro box connected with water tank: Note: ① Hydro box is only equipped with lower temperature sensor and water tank is equipped with upper temperature sensor. ②...
  • Page 15 Hydro Box of C H V5 Home Installation and Operation Manual (2) Installation diagram of hydro box connected with floor heating: (3) Installation diagram of solar power water heater connected with the system: (4) Installation diagram of connecting hydro box with water tank and floor heating simultaneously:...
  • Page 16 Hydro Box of C H V5 Home Installation and Operation Manual Note: ① The horizontal distance between hydro box and thermal insulation water tank shall not exceed 5m, and the vertical fall shall not exceed 3m. It is recommended to install the water tank at lower and install the hydro box at upper.
  • Page 17 Hydro Box of C H V5 Home Installation and Operation Manual from entering the pipe system. ⑤ The thermal insulation pressure water tank is supplied of hot water based on tap water pressure. The user can have hot water only when there is tap water. ⑥...
  • Page 18 Hydro Box of C H V5 Home Installation and Operation Manual a vertical fall of 3m to the hydro box. It can be installed indoors or outdoors, such as balcony, rooftop or floor. (2) The vertical thermal insulation water tank must be placed upright, with the bottom on ground.
  • Page 19 Hydro Box of C H V5 Home Installation and Operation Manual a specific length of PPR pipe. The length “L” is calculated as below: L≥70×R , in which “L” refers to pipe length (unit: cm) and R refers to the inner radius of the pipe (unit: cm). Thermal insulation shall be done and metal pipe shall not be used.
  • Page 20 Hydro Box of C H V5 Home Installation and Operation Manual...
  • Page 21 Hydro Box of C H V5 Home Installation and Operation Manual 3.2.6.3 Installation of Floor Heating Performer When connecting floor heating, it is recommended to install the floor heating performer in order to achieve control for different rooms and save energy. This hydro box is equipped with floor heating performer interface(single phase 220-240V), which can be connected with the floor heating performer in engineering installation.
  • Page 22 Hydro Box of C H V5 Home Installation and Operation Manual corresponding floor heating shunt valve no.: 1) Check the IDU project no. in its wired controller. For example: The IDU project no. in this room is “9”. 2) Check the floor heating shunt valve no. connected with the floor heating in the electric box of hydro box.
  • Page 23 Hydro Box of C H V5 Home Installation and Operation Manual...
  • Page 24 Hydro Box of C H V5 Home Installation and Operation Manual...
  • Page 25 220-240V ~ 50Hz HB16NK 60Hz Note: ① The power cable must be copper-core cable, and its working temperature shall not be higher than the specified value. ② If the power cable is longer than 15m, please increase its sectional area appropriately, thus to avoid overloading.
  • Page 26: Confirm Dip Switch Of Main Board

    Hydro Box of C H V5 Home Installation and Operation Manual the hydro box, and then insert it into the lower water temperature sensor port at the lower part of water tank. Connect the upper water temperature sensor included on water tank (i.e.
  • Page 27: Test Run

    Hydro Box of GMV5 Home Installation and Operation Manual ② The black part is the bar for setting DIP. 3.3.2 Function DIP(S ) of Hydro Box Note: Please set the DIP according to the actual status of project. Function DIP switch S2 is 4 bit. “1”, “2”, “3”and “4” stand for “C &H water tank”, “Floor heating”, “Solar power”...
  • Page 28 Hydro Box of C H V5 Home Installation and Operation Manual 3.4.2 Water Pipeline Debugging(leakage detection, air discharge) 3.4.2.1 Leakage Detection After connecting all waterway pipeline, please arrange leakage detection firstly and then arrange insulation to waterway system after making sure there is no water leakage. Please pay special attention to the thermal insulation at the joints of valves and pipe joints.
  • Page 29 Hydro Box of C H V5 Home Installation and Operation Manual 3.4.2.3 Air Exhausting of Water Tank and Pipeline at User Side (1) Make sure each pipe port of water tank is connected and make sure the sewage port of water tank is sealed;...
  • Page 30: Electrical Control

    Hydro Box of CH V5 Home Installation and Operation Manual 3.4.3 Corresponding Relationship Setting between Floor Heating Performer and Indoor Unit Please refer to 3.2.6.3. 3.4.4 Capacity Setting of Water Tank Please refer to 3.2.6.2. 3.4.5 Test Operation Arrange test operation of hydro box and outdoor unit simultaneously. Please refer to the test operation instruction in the instruction manual of outdoor unit.
  • Page 31: Common Malfunction And Troubleshooting

    Hydro Box of C H V5 Home Installation and Operation Manual 5 Common Malfunction and Troubleshooting 5.1 Error Code of Hydro Box Error code Content Error code Content Power supply overcurrent Water flow switch protection protection Malfunction of solar power Antifreezing protection temperature sensor Function DIP switch setting...
  • Page 32 Hydro Box of C H V5 Home Installation and Operation Manual 5.3 After-sales Services If there is quality problem or other problems for the product you purchased, please contact with the local after-sales service center. Warranty must comply with the following conditions: The first start-up of unit must be taken by the professionals of our after-sales service center or appointed company.

Table of Contents