  • Page 1 Aquarium Experts Ultimate Manual Model UATO-400P...
  • Page 2 Aquarium Experts Thank you for purchasing the XP Aqua Ultimate ATO. The Ultimate ATO is the world’s first quad-sensor ATO; with one sensor for top-off detection and two sensors for overfill detection. It also features a non-filling / run-dry detection sensor;...
  • Page 3: List Of Parts

    Aquarium Experts List of Parts Description Item Picture UltimateATO Controller AutoTopOffwith2xDualSensors Module UniversalPower UniversalPowerSupply:110V-240V Supply UniversalATO Forrimmedorrimlessaquariums TubingHolder upto1/2inch(12.7mm) ATODCPump Head:8.2feet(250cm) SiphonBreak Aconnectortobreakthesiphon Tubing6.5feet UsedwithATODCPump (200cm) ForconnectingwithACpumps ACSwitch (10AMax.) ForusewithRO/DISystems ROSolenoidValve...
  • Page 4: Controller & Accessories

    Aquarium Experts Controller & Accessories Ultimate ATO Controller Module 1.ControllerBracket 2.UltimateATOController 3.SecondaryOverfillProtectionSensor 4.PrimaryOverfillProtectionSensor 5.ATOLevelDetectionSensor 6.Non-filling /RunDryProtectionSensor 7.SensorHousing 8.DrySideMagnet(Yellow) 9.DrySideMagnet(Blue) 10.MagnetHousing Caution: RiskofInjuryfromStrongMagnets...
  • Page 5: Installation

    Aquarium Experts Installation I. Installation with Sensor Housing (Standard Installation) Mountthesensormoduletothesumpwiththemagnet. Movethesensortothenormalwaterlevelwiththewaterlevelreachingthe upperbluesensor. ConnectATOrefilltube(pump↔siphonbreak↔tubingholder). ConnectbothoftheDCpumpandpoweradapterwiththecontroller. *Pleaseavoidsettingupthesensorinanareawithmicrobubblesordirectlight. Siphonbreakmustbehigherthanthewater levelinthereservoir. AirIn:Siphonbreakallowsairintobreakthe siphonwhenthepumpturnsoff. AirIn Direction WaterOut:Waterdropsoutoftheholeare normalwhenthepumpison. WaterOut OpticalLevelSensor ATODCPump Reservoir Tank/Sump Power...
  • Page 6 Aquarium Experts II. Installation without Sensor Housing (Optional Installation) ForsumpswithEXTREMEwaterlevelfluctuations. Mountthebluedualsensoratthenormalwaterlevelonthetank/sump.* Mounttheyellowdualsensoratthedesiredsafetylevelonthetank/sump. ConnectATOrefilltube(pump↔siphonbreak↔tubingholder). ConnectbothoftheDCpumpandpoweradapterwiththecontrollerand thenconnectpower. *Pleaseavoidsettingupthesensorinanareawithmicrobubblesordirectlight. Siphonbreakmustbehigherthanthewater levelinthereservoir. AirIn:Siphonbreakallowsairintobreakthe siphonwhenthepumpturnsoff. AirIn Direction WaterOut:Waterdropsoutoftheholeare normalwhenthepumpison. WaterOut OpticalLevelSensor ATODCPump Reservoir Power Tank/Sump...
  • Page 7 Aquarium Experts III. AC Switch Installation (Using AC Pumps) Thisoptionisperfectforaquariumsthatrequirealarger/strongerATOpump. SimplyusetheACSwitchinplaceofthesuppliedDCpumpandpluginyour ownATOpump(10AMax.)intotheACSwitch. OpticalLevelSensor ACRefillPump Reservoir Power Tank/Sump ACSwitch...
  • Page 8 Aquarium Experts IV. Solenoid Valve Installation a. RO/DI System without Auto Shut Off (Installation Option 1) CutthetubingbetweenthecarbonblockfilterandtheROmembrane.Install thesolenoidvalve. *Arrowonsolenoidvalveindicateswaterflowdirection. Solenoid Valve Membrane DIFilter ¼” pipefrom ¼” pipeto pre-filtration ROinlet Feedwater system ROWaste Tank/Sump/Reservoir input Note:Filteredwaterisrequiredtopreventsediments SedimentCarbon fromcloggingthesolenoidvalve.Donotinstallthe solenoidvalvebeforeyourfiltrationsystem b. RO/DI System with Auto Shut Off (Installation Option 2) ConnectthesolenoidvalveattheRO/DIoutput. ThisoptioncanbeveryhelpfulwhentheRO/DIsystemisremotelylocated.
  • Page 9: Assembling The Housing

    Aquarium Experts Installation Housing a. Dismantling the Housing 1. R emovethecoveroffthesensorhousing.Takeoutthesensors. 2.Removethecoveroffthemagnethousing.Takeoutthemagnets. b. Assembling the Housing 1. P lacetheyellowdualsensorintheupperpositionofhousingwhiletheblue oneinthelowerposition,andputthecoverandthesensorhousingtogether. 2. P lacetheyellowandbluemagnetinthemagnethousingwiththelogofacing thecover.Putthecoverandthemagnethousingtogether.
  • Page 10: Led Indicator

    Aquarium Experts LED Indicator Status LEDColor Description Action Poweron N.A. Solid Circulating Refilling/Pumping N.A. Detectiondelayof Pulsinglight N.A. BlueLED safetysensors Checktheconnection Flashingwith Pumpconnection ofthepumpandthe shortbeeps failure controller. QSTalarm: 1.Movetheupperblue Alternating Flashingwith 1.Bubble sensortoanareaaway Blue & shortbeeps interference frommicrobubbles. Orange 2.Emptyreservoir 2.Refillthereservoir. 1.Keepthebluesensor Non-fillingalarmof Flashingslowly...
  • Page 11: Touch Button

    Aquarium Experts Detection Delay of Safety Sensors Allthesafetysensors(thelowerbluesensorsandtheupperyellowsensors) havedetectiondelaysof3minutesaftertheATOsystemisplugged-in.Ifyou wouldliketoskipthedelay,pressthecenterbuttononthecontrollertoallow thesensorstodetectthewaterlevelimmediately. Touch Button Touchbutton: 1.Skipthe3-minutedetectiondelayofsafetysensors. 2.Switchoffthealarm. *TouchthebuttonwillnotcleartheQSTmemory. Pleaseunplugthepowerandplugitbackintoclear theQSTmemory. Quick Security Technology (QST) UltimateATOusesQSTforreal-timeprotectionagainstanyfailuresituation. Thecontrollerwillgiveanaudibleandvisualalertwhenitsensesanyother refillingtimeis6timeslongerthanthefirstrefillingtime .Forexample,ifthe firstrefillingtimeis10sec,itwillalertwhenanyotherrefillingtimeisover 60sec. *Nosecuritytimecontrolforthefirstrefilling. Specifications 1.PowerInput:100-240VAC50-60Hz 2.DCPump: •Head:8.2ft(250cm) •FlowRate:74gph(280lph) 3.MaxMountingThickness:1/2inch(12.7mm) 4.ACSwitch: •Capacity:100-240VAC50-60Hz • M ax.Load:10A/1200W@120VAC;10A/2400W@240VAC 5.SolenoidValvePowerConsumption:6W@12VDC...
  • Page 12: Limited Warranty Policy

    Aquarium Experts Limited Warranty Policy 1.LimitedwarrantyisprovidedbyXPAquaonlyifyourXPAquaProduct ("Product")waspurchasedfromanauthorizeddistributororanauthorized reseller.Thislimitedwarrantyisnottransferable. 2.Allwarrantyrepairsorreplacementareperformedbytheauthorized distributororauthorizedresellerintheregionwheretheProductwasfirst shippedbyXPAqua. 3.Thelimitedwarrantyisvalidforaperiodof1yearunderproperinstallation andnormalusefromthedateoftheoriginalpurchaselistedontheproofof purchaseorsalesreceipt. 4.Intheeventofalimitedwarrantyclaim,proofofpurchaseorsalesreceipt (issuedtotheoriginalpurchaser)isrequired. PurchaseDate WarrantyPeriod Oneyearfromthepurchasedate (Y/M/D) PlaceofPurchase Service ExpertAquaCo.,Ltd. service@xpaqua.com www.xpaqua.com Storename/phone/email/address...