Advertisement

Quick Links

BARRIER-ATTIKA
Instruction manual
DE – ACHTUNG: Die Verwendung des INNOTECH-Produkts ist erst zulässig, nachdem die
Gebrauchsanleitung in der jeweiligen Landessprache vollständig gelesen und verstanden wurde.
EN – ATTENTION: Use of the INNOTECH product is only permitted after the instruction
manual has been read and fully understood in the respective language.
IT – ATTENZIONE: L'utilizzo del prodotto INNOTECH è permesso solo previa lettura e
comprensione dell'intero manuale di istruzioni nella lingua del relativo paese di utilizzo.
FR – ATTENTION : L'utilisation du produit INNOTECH n'est autorisée qu'après avoir
entièrement lu et compris la notice d'utilisation dans la langue du pays concerné.
NL – ATTENTIE: Dit INNOTECH-product mag pas gebruikt worden nadat u de gebrui-
kershandleiding in de taal van het betreffende land gelezen en begrepen hebt.
ES – ATENCIÓN: Se autorizará el uso de los productos INNOTECH una vez que se hayan
leído y entendido las instrucciones de uso en el idioma del país.
PT – ATENÇÃO: O uso do produto INNOTECH apenas é permitido depois de ter lido e
compreendido na totalidade as instruções de uso na respetiva língua nacional.
DK – GIV AGT: Du må først bruge et produkt fra Innotech, efter du har læst og forstået
brugsvejledningen i fuldt omfang i dit lands sprog.
SV – O B S : Denna INNOTECH-produkt får inte användas förrän bruksanvisningen på
respektive lands språk har lästs igenom och förståtts.
CZ – POZOR: Práce s výrobkem INNOTECH je povolena teprve po kompletním přečtení a
porozumění návodu k použití v jazyku daného státu.
PL – UWAGA: Produkty firmy INNOTECH mogą być używane dopiero po dokładnym
zapoznaniu się z całą instrukcją obsługi w ojczystym języku.
SL – POZOR: Uporaba izdelka INNOTECH je dovoljena šele po tem, ko ste navodila preb-
rali v celoti v ustreznem jeziku svoje dežele in jih tudi razumeli.
SK – POZOR: Produkt INNOTECH môžete používať až po prečítaní a porozumení celého
návodu na použitie pre príslušnú krajinu.
HU – FIGYELEM: Az INNOTECH termékek használata csak azt követően engedélyezett,
hogy saját nyelvén elolvasta és megértette a teljes használati utasítást.
TR – DİKKAT: INNOTECH ürününün kullanımına ancak ilgili ülkenin dilinde sunulmuş
olan kullanım kılavuzunun tamamen okunmasından ve anlaşılmasından sonra izin verilir.
注意:只有在仔细阅读并完全理解了当地语言的使用说明后,才能使用 INNOTECH 公司的产品。
ZH –

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BARRIER-ATTIKA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Innotech BARRIER-ATTIKA

  • Page 1 PT – ATENÇÃO: O uso do produto INNOTECH apenas é permitido depois de ter lido e compreendido na totalidade as instruções de uso na respetiva língua nacional. DK – GIV AGT: Du må først bruge et produkt fra Innotech, efter du har læst og forstået brugsvejledningen i fuldt omfang i dit lands sprog.
  • Page 2: Table Of Contents

    WARRANTY SIGNS & MARKINGS INSTALLATION TOOLS [10] INSTALLATION [11] SYSTEM-PARAPET AT TOP [12] SYSTEM-PARAPET AT SIDE [13] SYSTEM-PARAPET AT SIDE, HINGED [14] DISPOSAL [15] ACCEPTANCE LOG [16] INFORMATION ON THE SAFETY SYSTEM [17] TEST LOG [18] DEVELOPMENT & SALES BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 3: Description Of Symbols

    Wear safety glasses! Supplementary information/instructions  ü correct incorrect Comply with manufacturer's instructions/applicable instruction manuals. Work surface: Surface on which the persons stand, walk, or work. All vertical dimension specifications are provided in relation to this surface. Danger of falling/edge BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 4: Safety Instructions

    The area below the work site (pavement, etc.) must be kept clear. Plan, install, and use the safety system in such a way that no-one can fall over the edge if it is used correctly. See planning documents at www.innotech.at. Do not make any changes to the safety system.
  • Page 5 Correct use of the individual elements including "personal protective equipment" must be ensured, because otherwise the safe functioning of the safety system is NOT guaranteed. Do not use safety systems if wind speeds exceed normal parameters (max. wind zone 4). BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 6: Components/Material

    Adapter on the side of the parapet, foldable A22: Aluminium, stainless steel 304 Parapet adapter for attachment on the top of the parapet A31: Aluminium, stainless steel 304 Spacer bracket for parapet D82: Aluminium, stainless steel 304 Adapter for AIO-STA post BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 7 BARRIER-S21 post F23: Aluminium, stainless steel 304 Toe board connection set R11: Aluminium Aluminium pipe, straight R21: Aluminium, stainless steel 304 Linear tie R31: Aluminium, plastic, stainless steel 304 Corner tie R41: Aluminium, stainless steel 304 Wall tie BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 8 S21-1050: Aluminium, aluminium/zinc, stainless steel 304 Post, PARAPET system Standard length: 1050 mm Special lengths upon request T30: Aluminium, stainless steel 304 Door set S23-560: Aluminium, aluminium/zinc, stainless steel 304 Stiffening strut Z22: Aluminium/zinc End cap for a standard upright BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 9: Product Suitability/Approval

    Comply with the manufacturer's instructions for the personal protective equipment being used. INNOTECH "BARRIER" was tested and certified to the requirements of the standards EN ISO 14122-3:2016, DIN 14094-2:2017, and DIN EN 13374:2019 class A. The notified authority participating in the type test is:...
  • Page 10: Inspection

    INSPECTION INSPECT BEFORE EVERY USE Prior to each use, INNOTECH "BARRIER" must be inspected visually for any obvious defects. DANGER TO LIFE through damage to the INNOTECH "BARRIER". INNOTECH "BARRIER" must be in perfect working condition. Do NOT continue to use INNOTECH "BARRIER" if DANGER •...
  • Page 11: Warranty

    For system installation and for components planned and installed under the responsibility of specialised installation companies, INNOTECH assumes neither responsibility nor warranty in the case of incorrect installation. SIGNS & MARKINGS...
  • Page 12: Installation Tools

    INSTALLATION TOOLS [mm] AF = 4 AF = 2.5 Installation tools, various replacement parts and accessories are available from INNOTECH (www.innotech.at) (see INNOTECH price list). BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 13: Installation

    INSTALLATION DANGER TO LIFE if NOT correctly installed. Install INNOTECH "BARRIER" correctly as per the instruction manual. DANGER Comply with the specified tightening torques. INJURIES from sharp edges on components. CAUTION Wear protective gloves for the installation work. EYE INJURIES from dust/splinters/liquid.
  • Page 14 SYSTEM-PARAPET AT TOP 11.2 OVERVIEW Corners open Corners closed BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 15 ≤ ≤ 2200 2200 ≤ ≤ ≤ ≤ Corners open 2200 ≤ ≤ All separations, angles, etc. may vary with the circumstances of the respective safety system. The dimensions vertical to the floor always relate to the work surface. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 16 ≤ ≤ 2200 2200 ≤ ≤ ≤ ≤ Corners closed 2200 ≤ ≤ All separations, angles, etc. may vary with the circumstances of the respective safety system. The dimensions vertical to the floor always relate to the work surface. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 17 ≤ 470 mm, then no toe board is required. If the parapet is ≤ 150 mm, then a toe board is required. The dimensions vertical to the floor always relate to the work surface. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 18 C20/25, and the use of the original fasteners listed in this instruction manual. DANGER TO LIFE as a result of installation on unsuitable installation substructure. Install INNOTECH "BARRIER" on a statically load-bearing construction concrete (solid concrete) with a concrete quality of at least C20/25. DANGER DO NOT install on screed, levelling concrete, blinding concrete, etc..
  • Page 19 SYSTEM-PARAPET AT TOP 2 anchorage points are provided for installation. (Parapet adapter for attachment on the top of the parapet A21: 2 x Ø 15 mm) 11.7 INSTALLATION AF = 4 AF = 4 15 Nm BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 20 SYSTEM-PARAPET AT TOP Set the desired height. (Adjustment range = 43 mm) ü  Comply with the adjustment range. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 21 SYSTEM-PARAPET AT TOP Cut the R11 aluminium pipe to length. AF = 4 5 Nm AF = 4 BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 22 SYSTEM-PARAPET AT TOP SW 2,5 3,5 Nm AF = 2.5 OPTIONAL: Height adjustment of the pipe bracket BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 23: System-Parapet At Side

    SYSTEM-PARAPET AT SIDE 12.1 DIMENSIONS [mm] 624,6 119,5 A31 spacer bracket: Assembly: VARIANT I VARIANT II EXAMPLE OF USE: Parapet (concrete) Insulation Seal BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 24 SYSTEM-PARAPET AT SIDE 12.2 OVERVIEW Corners open Corners closed BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 25 ≤ 2200 2200 ≤ ≤ ≤ ≤ ≤ Corners open 2200 ≤ ≤ All separations, angles, etc. may vary with the circumstances of the respective safety system. The dimensions vertical to the floor always relate to the work surface. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 26 ≥ ≤ 2200 2200 ≤ ≤ ≤ ≤ Corners closed 2200 ≤ ≤ All separations, angles, etc. may vary with the circumstances of the respective safety system. The dimensions vertical to the floor always relate to the work surface. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 27 SYSTEM-PARAPET AT SIDE The dimensions vertical to the floor always relate to the work surface. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 28 C20/25, and the use of the original fasteners listed in this instruction manual. DANGER TO LIFE as a result of installation on unsuitable installation substructure. Install INNOTECH "BARRIER" on a statically load-bearing construction concrete (solid concrete) with a concrete quality of at least C20/25. DANGER DO NOT install on screed, levelling concrete, blinding concrete, etc..
  • Page 29 When installing the system directly on the parapet, use 2 anchorage points diagonally. 2 anchorage points are provided for installation of the spacer bracket. (Adapter on the inside of the parapet A11: 2 x Ø 15 mm) 4 x 15 Nm BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 30 SYSTEM-PARAPET AT SIDE 12.6 INSTALLATION Set the desired height. (Adjustment range = 10 mm) AF = 4 AF = 4 2 x 15 Nm BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 31 SYSTEM-PARAPET AT SIDE Cut the R11 aluminium pipe to length. AF = 4 5 Nm AF = 4 BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 32: System-Parapet At Side, Hinged

    SYSTEM-PARAPET AT SIDE SW 2,5 3,5 Nm AF = 2.5 OPTIONAL: Height adjustment of the pipe bracket SYSTEM-PARAPET AT SIDE, HINGED 13.1 DIMENSIONS 167,2 [mm] BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 33 SYSTEM-PARAPET AT SIDE, HINGED A31 spacer bracket: Assembly: VARIANT I VARIANT II EXAMPLE OF USE: Parapet (concrete) Insulation Seal 13.2 OVERVIEW folded BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 34 ≤ ≥ ≤ ≥ ≤ 1075 2100 1075 ≤ 1120 1120 ≤ ≤ All separations, angles, etc. may vary with the circumstances of the respective safety system. The dimensions vertical to the floor always relate to the work surface. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 35 SYSTEM-PARAPET AT SIDE, HINGED Adapter on the inside of the parapet, hinged, A11 must be installed at least 150 mm above the surface (e.g. gravel filling or vegetation layer). 1135 The dimensions vertical to the floor always relate to the work surface. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 36 C20/25, and the use of the original fasteners listed in this instruction manual. DANGER TO LIFE as a result of installation on unsuitable installation substructure. Install INNOTECH “BARRIER” on statically load-bearing construction concrete (solid concrete) having a concrete quality of at least C20/25. DANGER DO NOT install on screed, levelling concrete, blinding concrete, etc..
  • Page 37 (Adapter on the side of the parapet, hinged A11: 4 long holes: Ø 13 x 17 mm) When installing the system directly on the parapet, use 2 anchorage points diagonally. 2 anchorage points are provided for installation of the spacer bracket. (Adapter on the inside of the parapet, hinged A31: 2 x Ø 15 mm) BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 38 SYSTEM-PARAPET AT SIDE, HINGED 13.6 INSTALLATION AF = 4 AF = 4 2 x 15 Nm BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 39 SYSTEM-PARAPET AT SIDE, HINGED Cut the R11 aluminium pipe to length. AF = 4 5 Nm AF = 4 ü BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 40 SYSTEM-PARAPET AT SIDE, HINGED SW 2,5 3,5 Nm AF = 2.5 OPTIONAL: Height adjustment of the pipe bracket BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 41: Disposal

    The safety system is dismantled in reverse order to the installation instructions. Protect by means of an alternative safety system. Do NOT dispose of the safety system in household waste. As per national requirements, collect the used parts together, and dispose of them in an environmentally correct manner. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 42: Acceptance Log

    P R O T E C T I O N S Y S T E M ORDER NUMBER PROJECT CLIENT  Specialist: Company address: CONTRACTOR:  Specialist: Company address: INSTALLATION: Side protection system DESIGNATION: Side protection system no. Length: _______m  Specialist: Company address: BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 43 The technical safety reliability is confirmed by the installation company. Comments: _________________________________________________________ Included in lightning protection system? Name: Client Fitter, anchorage points Date, company stamp, signature Date, company stamp, signature Fitter of side protection system Date, company stamp, signature BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 44: Information On The Safety System

    Overview plan showing the position of the side protection system: Draw in the areas where there is a break-through hazard (such as skylights and/or light strips)! Damaged parts of the railing must be replaced immediately by a competent/specialised person who is familiar with the BARRIER side protection system. BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 45: Test Log

    (Max. separation between posts 2200 mm, separation from the work surface, etc.)  Separations for the applicable system as per instruction manual  Aluminium pipe: (firm seat, threaded joints (tightening torque), no deformation, etc.)  Aluminium pipes  R11  BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 46 Acceptance result: The safety system corresponds to the manufacturer's instruction manual, and to the state of the art. Technical safety reliability is confirmed. Comments: _________________________________________________________ Name: ________________________ ________________________ Client Inspection: Contractor (expert who is familiar with the safety system) ________________________ ________________________ Date, company stamp, signature Date, company stamp, signature BARRIER-ATTIKA/190611/www.innotech.at...
  • Page 47: Development & Sales

    DEVELOPMENT & SALES INNOTECH Arbeitsschutz GmbH, Laizing 10, 4656 Kirchham/Austria www.innotech.at BARRIER-ATTIKA/190611/www.innotech.at...