Summary of Contents for Redlake MASD MotionScope PCI 500
Page 1
sales@artisantg.com artisantg.com (217) 352-9330 | Click HERE Find the Redlake Imaging 54000110 at our website:...
Page 2
INSTRUCTIONS FOR OPERATING â THE MotionScope HIGH SPEED DIGITAL IMAGING SYSTEM (Photo for illustration only. Your system may differ.) Redlake MASD, Inc. 11633 Sorrento Valley Road San Diego, California 92121-1010 Telephone: 1-800-854-7006 (USA and Canada only). Outside the USA: 858-481-8182 Fax : 858-481-6254 Internet : www.redlake.com...
Page 3
Add PCI spec to Appendix B. 02-01-01 App A, add performance parameters for 500 and 500C. 05-15-01 Conversion to Redlake MASD, Inc. and general corrections. 02-15-02 Added CAUTION regarding saving files while in playback mode. Changed logo. All changes identified by vertical bar in margin.
Page 4
High Speed Digital Imaging System, monochrome or color. The MotionScope PCI Controller is installed in a computer and runs on the Redlake MASD, Inc. PCI program. All controls and instructions are entered at the keyboard or by clicking the mouse pointer on a menu.
Page 5
The information in this manual is for information purposes only and is subject to change without notice. Redlake MASD, Inc. makes no warranty of any kind with regards to the information contained in this manual, including but not limited to implied warranties of merchantability and fitness for a particular purpose. Redlake MASD, Inc. shall not be liable for errors contained herein nor for incidental or consequential damages from the furnishing of this information.
â MotionScope PCI High Speed Video System TABLE OF CONTENTS · INTRODUCTION TO HIGH SPEED MOTION ANALYSIS Capturing the Video Image .................... 1-1 1.1.1 The Shutter ......................1-1 1.1.2 The Strobe Output....................1-1 1.1.3 Lighting the Subject ....................1-1 The Imager Responsivity Curves ................... 1-2 1.2.1 The Imager Base Characteristics ................
Page 7
REDLAKE MASD, INC. 2.4.3 Loading the Application Program................2-2 Power On and Loading the Software (Windows NT 4.0) ..........2-3 Viewing the Live Picture....................2-3 Setting the Camera Options................... 2-3 2.7.1 Naming the Camera and Loading Default or New Data ......... 2-3 Connecting the External Options ...................
Page 8
â MotionScope PCI High Speed Video System 3.10.3.2 Deleting Set Points ..................3-12 3.10.4 Exporting the Data Points Listing................3-12 3.11Synchronizing a Video Sequence..................3-12 · RECORDING ON THE MOTIONSCOPE PCI SYSTEM 4-1 Load the MotionScope Program and Open the Camera Window........4-1 Setting up the Camera to Record ..................
Page 9
REDLAKE MASD, INC. LIST OF FIGURES Figure 1-1 The Spectral Characteristics of the TC237 Sensor............ 1-2 Figure 1-2 The Response of the RGB Signal with an IR Filter............. 1-2 Figure 1-3 Filter Blocking Characteristics..................1-2 Figure 1-4 Sensor RGB Spectral Response without an IR Filter..........1-3 Figure 1-5 The Monochrome Curve.
Page 10
â MotionScope PCI High Speed Video System LIST OF TABLES Table 1-1 Light Value Requirements for the PCI System............1-1 Table 3-1 The PCI Model and Part Numbers................3-1 _____________________________________________________________________________ 9400-0010 Rev. S OPERATOR'S INSTRUCTIONS Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 11
REDLAKE MASD, INC. THIS PAGE INTENTIONALLY LEFT BLANK. _____________________________________________________________________________ 9400-0010 Rev S 02/15/02 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
â MotionScope PCI High Speed Video System 1 INTRODUCTION TO HIGH SPEED MOTION ANALYSIS The MotionScope High Speed Digital Imaging System records a sequence of digital images of an event at a frame rate of 60 to 8000 frames per second, depending on the model of video system used.
REDLAKE MASD, INC. The Imager Responsivity Curves The camera head has either the TC236 (color) or TC237 (monochrome) CCD imager. These imagers have the same characteristics. The imaging sensor has an image area of 658 (H) x 496 (V) pixels, each pixel being 7.4 microns square.
â MotionScope PCI High Speed Video System 1.2.4 Spectral Response without the C500 IR Filter This set of curves shows the spectral response for the red, green, and blue signals without an IR filter. See Figure 1-4. Blue Green Figure 1-4 Sensor RGB Spectral Response without an IR Filter. 1.2.5 The Monochrome Curve ·...
REDLAKE MASD, INC. The trigger input stops the sequence on the frame where the event occurred. You can set the Trigger Point to record part of the sequence before the event, and the remainder after the event. This insures that the event shows on Frame 0 of the sequence, which synchronizes the elapsed time on each frame in the sequence to the event.
â MotionScope PCI High Speed Video System The system records the events and assigns a sequential frame number to each frame. However, if the rate of recording frames varies from a record rate of 60, 125, 250, 500, 1000, 2000 or 8000 frames per second, the elapsed time (ET) displayed on the Playback window will not be the true elapsed time.
REDLAKE MASD, INC. 1.5.2 Stop Recording using the Trigger The camera also stops recording when it receives a signal through the Trigger input. Recording stops at the frame determined by the Trigger Point setting, see Figure1-8. The trigger can be set...
â MotionScope PCI High Speed Video System 1.5.5 Saving a Sequence in a Computer File. Images recorded in the image memory will be lost if another recording is made. Therefore any video data required later must be stored in a computer file before making another recorded sequence.
REDLAKE MASD, INC. 1.6.2 Analyzing the Motion of a Subject The MotionScope system provides several features to examine a recorded sequence, whether the sequence is still in the image memory or has been recorded and retrieved from a computer file. These features are available on all models.
â MotionScope PCI High Speed Video System 2 INSTALLING THE MOTIONSCOPE PCI SYSTEM This section specifies the minimum computer requirements, and gives procedures to install the MotionScope adapter and software. It describes how to connect the Camera Head and power up the system.
The drivers are loaded. Proceed to 2.2 below. NOTE: The Wizard window may show the driver file with a yellow “?” icon. This should not cause concern, and only means that Windows does not recognize the Redlake MASD, Inc. file format.
â MotionScope PCI High Speed Video System Power On and Loading the Software (Windows NT 4.0) 1. Turn the computer ON. 2. Insert the MotionScope PCI CD-ROM into the drive. Follow the installation directions. 3. When installation is complete, restart the computer. 4.
REDLAKE MASD, INC. The Strobe signal is a TTL pulse generated by U2 on the Controller board, a 74AC244 device, shown in Figure 2-2. The output is through a lead to a BNC connector on the camera cable labeled “STROBE”. The user must supply a coax cable terminated with a female BNC connector.
â MotionScope PCI High Speed Video System 1. The signal input is held at +5 volts. A contact closure to ground caused by the Trigger pulls the input to 0 volts to stop recording. This presents a falling signal edge to the trigger input so you must check the Falling box in the Trigger dialog box.
Page 25
REDLAKE MASD, INC. THIS PAGE INTENTIONALLY LEFT BLANK. _____________________________________________________________________________ 9400-0010 Rev S 02/15/02 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
â MotionScope PCI High Speed Video System 3 DESCRIPTION OF THE MOTIONSCOPE PCI SYSTEM The MotionScope PCI system has a Camera Head, a camera cable, and a full length PCI Controller board. The product includes the MotionScope PCI application software provided on a CD-ROM disk.
REDLAKE MASD, INC. 4. Data Record Input 0; Data Record Input 1. Each Data Record input controls a marker on the video image. These inputs must be TTL signals; when the signal is +5 volts, the marker is white, and when the signal goes low (0 Volts), the marker goes black. These signal levels may be changed independently at any time during Record to identify a specific frame.
â MotionScope PCI High Speed Video System When you open the camera window for the first time you are prompted for a camera name, see Figure 3-2. The window then shows the live picture from the camera. When a recording has been made, this window shows live video from the camera (Live mode) or the recorded sequence stored in the image memory if you click on Play (Play mode).
REDLAKE MASD, INC. Viewing and Setting the Operating Parameters These parameters must be set to record a sequence: the Event number and description; the Record Rate; and the Shutter. Set the Trigger if it will be used to stop the recording.
Description. This indicates the current status for the system. Normally the message says: ”The Camera is working properly.” Contact Redlake MASD, Inc. or your supplier if this field shows any other message. Figure 3-8 The Camera Properties. Recording an Event...
REDLAKE MASD, INC. The Slider stops at the position of the last frame. The display shows the number of frames recorded and the elapsed time of the sequence referenced to Frame 0. Since the image memory is overwritten in a loop, the recorded sequence will never be longer that the memory available.
â MotionScope PCI High Speed Video System 3.8.3 File Compression When you save an AVI file, you are prompted for a compression standard. Select a compression standard from the list, or go with the default of no compression, see Figure 3-11. Select from: ·...
REDLAKE MASD, INC. 3.9.3 Reviewing the Right Click Menu Place the pointer on the file window and click on the right mouse button for a drop-down menu with these functions: · Reticle... Click on Reticle to activate and use the Reticle function, see 3.10 below.
â MotionScope PCI High Speed Video System The Dialog box shown in Figure 3-14 gives details of the record settings such as the record rate, shutter setting, number of frames stored, length of the sequence and the resolution of the video frames in pixels.
REDLAKE MASD, INC. 3.10.2 Enabling the Reticle · With a recorded image sequence in the window, click on the Reticle button. The Reticle menu appears with the Reticle Enable field shown. Alternatively you may right click on the image and a menu appears.
â MotionScope PCI High Speed Video System 3.10.3 Calibrating the Reticle Feature When you calibrate the reticle feature, you can measure physical distances on the monitor. If you set another data point on the frame, the system shows the distance between the two points in the units selected in the...
REDLAKE MASD, INC. 3.10.3.1 Data… You can manually track the target, in this case the ball, by moving a few frames forward or back and placing a set point on the ball in each frame. Call up the Reticle menu and click on Data…...
â MotionScope PCI High Speed Video System 4 RECORDING ON THE MOTIONSCOPE PCI SYSTEM This Section describes how to load the MotionScope program and open the camera window. You can then enter the required record parameters and record a video sequence in the image memory.
REDLAKE MASD, INC. 4.2.2.5 Data Record Inputs. 1. These inputs are normally disabled. 2. If you are using the Data Record Inputs 0 and 1, enable the feature by setting SW7, refer to paragraph 3.4. Recording an Event Sequence When the parameters described in paragraph 4.2 have been set, you are now ready to record.
â MotionScope PCI High Speed Video System Recording from an External Signal Source A MotionScope camera in Slave mode can record images synchronized to an external source, when a phase lock signal is input into the Phase Lock In connector. Refer to paragraph 2.7.5 for details of the Phase Lock In signal.
Page 41
REDLAKE MASD, INC. THIS PAGE INTENTIONALLY LEFT BLANK. _____________________________________________________________________________ 9400-0010 Rev S 02/15/02 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
â MotionScope PCI High Speed Video System 5 VIEWING AND PROCESSING STORED IMAGES Each recorded sequence overwrites the existing contents of the Image Memory. You must save an event sequence in a computer file before you make another recording. This section describes how to save a sequence of images, replay them, and study the subject by viewing at different frame rates.
REDLAKE MASD, INC. Setting up the Reticle to Measure Motion The Reticle can be used to measure the distances and speed of travel of a point of interest in the event sequence. First enable the Reticle feature, create the Set Points, and then calibrate the Reticle to give accurate distance and velocity readings.
The frequency of cleaning depends on the operating environment. Use a lens brush; do NOT wipe the lens with a cloth or tissue. If the suggestions given in this section do not resolve the problem, call Redlake MASD, Inc. or your local representative.
REDLAKE MASD, INC. 6.2.4 Video Channel Imbalance The video image is taken from two analog video channels from the Imager in the camera. If these two channels are not balanced you will see a picture with horizontal lines as shown in Figure 6-2. Call your nearest service representative or Redlake MASD, Inc..
â MotionScope PCI High Speed Video System APPENDIX A PERFORMANCE PARAMETERS These tables give the record times and frame storage for all PCI models. The suffix E denotes extended record time. The suffix S indicates a full width reduced size image. MotionScope Ò...
Page 47
REDLAKE MASD, INC. MotionScope Ò 8000 S Monochrome Recording Time / Frame Storage (Sec.) Frame Rate Resolution Standard Memory Enhanced Memory Maximum Memory (Frames/Sec) (Pixels) # of Record # of Record # of Record Frames Time Frames Time Frames Time 480 x 420 10.2 Sec.
â MotionScope PCI High Speed Video System APPENDIX B PERFORMANCE SPECIFICATIONS â Software Point and click environment for Windows NT with Service Pack 5; or â Windows 2000 Computer Requirement Minimum Pentium II with MMX, 1024x768 display, 128Mb RAM, 3Gb Hard Drive, CD-ROM Drive, ZIP or JAZ Drive, 2 PCI Slots.
REDLAKE MASD, INC. APPENDIX C EXPOSURE AT EACH SHUTTER SPEED This table gives exposure times and the length of the strobe signal output over the range of the shutter speeds. Shutter speeds of 1X to 20X are available on all models.
â MotionScope PCI High Speed Video System APPENDIX D ACCESSORIES Standard Accessory Kit for the MotionScope System 1900-0001 Includes Tripod, Light Kit, Zoom Lens, Trigger Switch, Articulated Arm with Clamp, and Storage/Shipping Case. Memory Upgrade 2700-0003 Enhanced Memory Upgrade 2700-0001 Maximum Memory Upgrade 2700-0002 Hi-G Camera Option...
Page 51
REDLAKE MASD, INC. Appendix C (Continued): Cables: Camera Cable, 15 ft with seven 12” Pigtail Connectors 1800-0002 Camera Cable, 50 ft with seven 12” Pigtail Connectors (Monochrome only) 1800-0004 Cable Co-Ax 10-foot with BNC Connectors 9031-0019 Power cord, 9037-0011 Monitors and VCRs: Monitor, Sony PVM-137, 14”...
Need help?
Do you have a question about the MotionScope PCI 500 and is the answer not in the manual?
Questions and answers