Mounting to a Gasketed Cabinet (Internal Sink)
The standard enclosure (with the heatsink
mounted internally) can be easily changed to
an externally mounted heatsink arrangement,
but the enclosure's mounting face must be
gasketed.
55 ℃ 
45 ℃ 
VS−656RC5 Heat Loss
200 V Class
Model  CIMR−R5A
Rated Capacity 
Rated Current
Fin 
Inside Unit 
Total Heat Loss
Fin Cooling
* Values are the regenerative torque at 80 % continuous rating.
400 V Class
Model  CIMR−R5A
Rated Capacity 
Rated Current
Fin 
Inside Unit 
Total Heat Loss
Fin Cooling
* Values are the regenerative torque at 80 % continuous rating.
8
INTERNAL HEATSINK
UPPER COVER
UPPER PART AIR TEMPERATURE 
−10 TO 55 ℃ 
HEATSINK
OPEN CHASSIS 
TYPE POWER 
REGENERATIVE UNIT
LOWER COVER
INLET AIR 
TEMPERATURE 
−10 TO 45 ℃ 
PERIPHERAL 
TEMPERATURE 
40 ℃ 
23P7
25P5
27P5
kW 
3.7 
5.5 
7.5 
A
13 
19 
26 
70 
70 
90 
60 
60 
80 
130
130
170
43P7
45P5
47P5
kW 
3.7 
5.5 
7.5 
A
13 
30 
40 
60 
50 
60 
60 
80
100
120
Remove the uppper and lower covers for the models 
of 30 kW or less in 200 V and 400V classes.
COVER MTG SCREW
2011
2015
2018
2022
11 
15 
18.5 
22 
37 
51 
64 
77 
160 
200 
250 
320 
110 
130 
150 
180 
270
330
400
500
Fan cooled
4011
4015
4018
4022
11 
15 
18.5 
22 
19 
26 
32 
37 
80 
110 
120 
140 
70 
90 
100 
110 
150
200
220
250
Fan cooled
UPPER COVER
HEATSINK
LOWER COVER
2030
2037
30 
37 
102 
126 
410 
540 
220 
290 
630
830
4030
4037
4045
4055
30 
37 
45 
55 
51 
64 
77 
96 
210 
290 
360 
470 
140 
160 
190 
260 
350
450
550
730
4075
75 
128 
550 
310 
860

Advertisement