Tektronix VX1411 Instruction Manual
Tektronix VX1411 Instruction Manual

Tektronix VX1411 Instruction Manual

Vxibus mainframe
Table of Contents

Advertisement

Quick Links

sales@artisantg.com
artisantg.com
(217) 352-9330 |
|
Click HERE
Find the Tektronix VX1411 at our website:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VX1411 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tektronix VX1411

  • Page 1 (217) 352-9330 | Click HERE Find the Tektronix VX1411 at our website:...
  • Page 2 Instruction Manual VX1411 VXIbus Mainframe 070-9602-00 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to the Safety Summary prior to performing service.
  • Page 3 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. Printed in the U.S.A. Tektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000 TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
  • Page 4 Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located.
  • Page 5 ....... . 6–12 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 6 ......... 7–1 VX1411 Mainframe Common Replaceable Parts ......
  • Page 7: Table Of Contents

    ..4–10 Figure 4–4: Front view and side view of VX1411 Mainframe with Option 1U and rackmount option ........
  • Page 8 ......7–17 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 9 Table of Contents List of Tables Table 1–1: VX1411 Mainframe options and upgrade kits ..1–3 Table 1–2: Power cord identification ......
  • Page 10 Use Proper Power Source. Do not operate this product from a power source that Precautions applies more than the voltage specified. Provide Proper Ventilation. To prevent product overheating, provide proper ventilation. VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 11 Symbols on the Product. The following symbols may appear on the product: DANGER Protective Ground ATTENTION Double High Voltage (Earth) Terminal Refer to Manual Insulated viii VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 12 Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components. VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 13 The VX1411 Mainframe Instruction Manual provides information on using the mainframe. The manual includes the following chapters: Getting Started provides a brief description of the VX1411 Mainframe, a list of accessories that accompany the mainframe, installation and configuration procedures, and a functional check procedure.
  • Page 14 Getting Started This chapter provides an overview of the VX1411 Mainframe. It includes installation and configuration information on user installed options. Product Description The VX1411 Mainframe is a 13-slot, C-size, VXIbus Mainframe. It fully complies with the VXIbus Specification 1.4 requirements and is VXIplug&play compatible.
  • Page 15 Full differential distribution of the CLK10 signals provide a clean timing source for your VXIbus instruments. Optional Rackmounts and You can order the VX1411 Mainframe with user-installed rackmounts and cable Cable Tray tray. The cable tray provides a means to conveniently route cables from the front of the modules to the rear of the mainframe.
  • Page 16: Table 1-1: Vx1411 Mainframe Options And Upgrade Kits

    Getting Started Options and Upgrade Kits Table 1–1 lists the VX1411 Mainframe options and upgrade kits that you can purchase and install separately. Contact your local Tektronix representative for information on the upgrade kits. Table 1–1: VX1411 Mainframe options and upgrade kits...
  • Page 17: Table 1-2: Power Cord Identification

    Getting Started Standard Accessories The VX1411 Mainframe comes with the following standard accessories: VX1411 Mainframe Instruction Manual One Power cord (voltage range and plug type varies according to country, see Table 1–2) 5 x 20 mm line fuse, 4 A, 250 V 5 x 20 mm line fuse holder Table 1–2: Power cord identification...
  • Page 18: Table 1-3: Line Fuse Application

    Backplane EMI DIN shields (Tektronix part number 020-2144-00) Selecting the Correct Power Cord and Fuse The VX1411 Mainframe comes standard with a power cord and two fuses. Before installing the mainframe, you must determine the correct fuse for your application. Use the following information to determine the appropriate line fuse for the VX1411 Mainframe: Table 1–3: Line fuse application...
  • Page 19 Site Considerations The VX1411 Mainframe is designed to operate on a bench or in a rackmount environment. For proper cooling, allow at least two inches (5.1 cm) of clearance on the rear and sides of the mainframe. Determine how you will use your VX1411 Mainframe and follow the appropriate installation instructions.
  • Page 20 Install feet (optional) Install cable tray and tighten 4 screws. Figure 1–1: Installing the Option 1U as a 1.75-inch deep cable tray 1–7 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 21 Install cable tray and tighten 4 screws. Reinstall 4 screws from feet. Figure 1–2: Installing the Option 1U as a 2.5-inch deep cable tray 1–8 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22 Install 4 screws; do not tighten. Turn 2 rails 90 . Figure 1–3: Installing the Option 1U as a 4.25-inch deep cable tray 1–9 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 23 2. Determine whether you want to install the VX1411 Mainframe so that it extends out of the rack or is recessed within the rack. If you want to extend the VX1411 Mainframe from the front of the rack, position the rackmount bracket as shown on the right side of Figure 1–4. If you want to recess the VX1411 Mainframe in the rack, position the rackmount bracket as shown on the left side of Figure 1–4.
  • Page 24: Figure 1-4: Installing The Rackmount Kit Hardware

    4. Remove the five 8-32 screws from both sides of the mainframe. 5. Attach the left and right inside tracks to the sides of the VX1411 Mainframe using five 8-32 flathead screws. Orient the button latch so that it faces away from the mainframe and toward the rear.
  • Page 25: Figure 1-5: Assembling The Slide-Out Track Assemblies

    Getting Started Install the Mainframe Use the following procedure to install the VX1411 Mainframe in the rack: in the Rack 1. Identify the right and left slide-out track assemblies: find the date code label on each assembly. The assembly to be mounted in the left side of the rack (the side nearest the left side of the mainframe when it is mounted in the rack) has a date code that ends with LH (for left hand).
  • Page 26: Figure 1-6: Vertical Clearance For Rack Installation (Standard Mainframe)

    A shown in Figure 1–7 when doing step 8. Add a bar nut to the installation only if the rails have untapped holes. 1–13 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 27: Figure 1-7: Installing The Slide-Out Track Assemblies

    Mounting method B Figure 1–7: Installing the slide-out track assemblies in the rack (top view) WARNING. Installing the VX1411 Mainframe in the rack requires at least two people. Because of the size and weight of the mainframe, installing the main- frame alone can result in personal injury or equipment damage.
  • Page 28 You can adjust the catch position forward or back to assure a flush fit between the door and the rackmount bracket. 4. Lift the rackmount door and mate the door with the hinges. 1–15 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 29: Figure 1-8: Installing The Rackmount Door (Option 2R)

    2 Flat head screws Hinges 2 Pan head screws Catch Rackmount door Rackmount bracket Figure 1–8: Installing the rackmount door (Option 2R) 1–16 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 30 Procedure 4: Removing the Card Guides beginning on page 6–9 in the Maintenance chapter. Module Selection and The VX1411 Mainframe is UL listed to UL 3111-1 and CAN/CSA C22.2 Design Guidelines No. 1010.1 and is IEC 1010-1 compliant. You should use VXIbus modules with the mainframe that are listed or designed to limit electric shock and fire.
  • Page 31: Figure 1-9: Installing The Empty Slot Panel Fillers

    Install either the optional single-wide or double-wide fillers. CAUTION. Use only Tektronix front panels; otherwise the shutters may activate, effectively robbing airflow from installed modules. Installing the fillers provides improved cooling for installed modules and improved EMI shielding.
  • Page 32: Figure 1-10: Locations Of Safety And Chassis Ground Connections On Left Rear Of The Mainframe

    Getting Started Safety and Chassis The left rear of the VX1411 Mainframe has a connection point for the chassis Grounds ground (see Figure 1–10). WARNING. The safety ground screw must always be in place to ensure the proper bonding of the power supply to the mainframe. You can use the chassis ground connection to connect the grounds of one or more instruments to the mainframe.
  • Page 33: Figure 1-11: Installing The Backplane Emi Din Shields

    5. Reinstall any modules that you removed in step 2. 2 Screws Backplane EMI DIN shield Figure 1–11: Installing the backplane EMI DIN Shields 1–20 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 34: Figure 1-12: Installing The Emi Intermodule Shield And Front Panel Emi

    Double panel EMI filler Single panel EMI filler EMI intermodule shield Figure 1–12: Installing the EMI intermodule shield and front panel EMI fillers 1–21 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 35: Table 1-4: Power Supply Voltages P1 And P2 Of The Extender Card

    Getting Started Functional Check Use the information in this section to determine that the VX1411 Mainframe operates properly. The functional check consists of checking the power supply voltages from the extender card with a digital voltmeter. Connect one lead of the voltmeter to the extender card pins inserted into slot 0 of the mainframe.
  • Page 36: Figure 2-1: Front View Of The Vx1411 Mainframe

    This chapter provides a brief overview of the VX1411 Mainframe including illustrations and descriptions of switches, indicators, and connectors. Figure 2–1 shows the front view of the VX1411 Mainframe. All of the main- frame slots are labeled on the top and bottom of the mainframe. Slot 0 is reserved for the mainframe controller;...
  • Page 37 The switch is a momentary contact switch. The switch is lighted when DC voltages are applied to the mainframe. Figure 2–3 shows the rear view of the standard VX1411 Mainframe. The AC power connector is located on the bottom left side on the rear of the mainframe.
  • Page 38: Figure 2-3: Rear View Of The Vx1411 Mainframe

    Operating Basics Fan filter Fan speed switch Fuse AC Power Figure 2–3: Rear View of the VX1411 Mainframe 2–3 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 39 This chapter provides reference information on the mainframe and its connectors. Backplane Connectors Table 3–1 shows the P1 connector pinouts for all slots in the VX1411 Main- frame. Table 3–2 shows the P2 connector pinouts for slots 1 to 12 and Table 3–3 shows the pinouts for the Slot 0 P2 connector.
  • Page 40: Table 3-1: P1 Connector Pinouts

    IACKOUT* SERDAT* IRQ7* IRQ6* IRQ5* IRQ4* IRQ3* IRQ2* IRQ1* –12 V +5 V STDBY +12 V +5 V +5 V +5 V 3–2 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 41: Table 3-2: P2 Connector Pinouts For Slots

    LBUSA11 LBUSC11 TTLTRG0* TTLTRG1* TTLTRG2* TTLTRG3* +5 V TTLTRG4* TTLTRG5* TTLTRG6* TTLTRG7* RSV2 RSV3 MODID +24 V SUMBUS +5 V –24 V 3–3 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 42: Table 3-3: P2 Connector Pinouts For Slot 0

    MODID01 LBUSC11 TTLTRG0* TTLTRG1* TTLTRG2* TTLTRG3* +5 V TTLTRG4* TTLTRG5* TTLTRG6* TTLTRG7* RSV2 RSV3 MODID00 +24 V SUMBUS +5 V –24 V 3–4 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 43: Table 4-1: Ac Power Source

    Specifications This chapter contains the complete specifications for the VX1411 Mainframe. Within each section, the specifications are arranged in functional groups such as: AC Power Source, Secondary Power, Cooling, Safety, Environmental, Back- plane, and Mechanical. All specifications are warranted unless they are designated typical. DC Voltage Regulation is a warranted characteristic and can be directly checked by proce- dures contained in the Performance Verification chapter beginning on page 5–1;...
  • Page 44: Table 4-2: Secondary Power

    –100 mV, +100 mV –5.2 V –260 mV, +156 mV –12 V –600 mV, +360 mV –24 V –1.2 V, +720 mV 4–2 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 45 Undervoltage protection results in the supply shutting down and staying down until the AC line input achieves high enough voltage at which time the supply will turn on. 4–3 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 46: Figure 4-1: Power Output Versus Temperature For The 2 Fan Speeds

    Low or full fan speed 50 55 60 Ambient temperature ( C) Figure 4–1: Power output versus temperature for the 2 fan speeds 4–4 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 47: Figure 4-2: Mainframe Cooling Curve

    ∆ Pressure across module (mm H 0.50 0.25 0.00 Note: Proposed VXI–8 cooling methods Airflow through module (l/s) Figure 4–2: Mainframe cooling curve 4–5 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 48: Table 4-4: Environmental

    Specifications Table 4–4: Environmental Characteristic Description Classification The VX1411 Mainframe is suitable for operation in the Tektronix and MIL-T-28800E (Type III, Class 5, Style E or F) environments as specified in this table. Atmospherics Temperature Meets the limits stated in MIL-T-28800E for Type III, Class 5 Operating 0 C to 55 C, derated 1 C/1000 ft.
  • Page 49: Table 4-5: Certifications And Compliances

    The mainframe complies with the radiated and conducted emissions requirements of FCC 47 CFR, Part 15, Subpart B, Class A equipment Open circuit voltage (short circuit current) transient characteristics. 4–7 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 50: Table 4-6: Backplane

    Full differential Table 4–7: Mechanical Characteristic Description Overall Dimensions Standard Mainframe Height (with feet) 14.4 in (36.58 cm) Width 16.7 in (42.42 cm) 4–8 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 51 Module Size 13 C-size VXI slots. The mainframe also accepts A-size or B-size modules using the 73A-851 module. Finish Tektronix smoke tan and graphite grey paint on an aluminum chassis 4–9 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 52: Figure 4-4: Front View And Side View Of Vx1411 Mainframe With Option 1U

    (15.75 in) 44.5 cm (17.50 in) Figure 4–4: Front view and side view of VX1411 Mainframe with Option 1U and rackmount option 4–10 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 53: Table 4-8: Vxi And Vxiplug&Play

    Specifications Table 4–8: VXI and VXIplug&play Characteristic Description Fully compatible with VXIbus System Specifications, Rev 1.4 VXIplug&play Mainframe VXIplug&play compliant with VPP-8 4–11 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 54 Performance Verification Use this chapter to verify that the VX1411 Mainframe operates properly. The checks consist of installing a 73A-850 extender card into slot 0 of the main- frame. Check the power supply voltages with a DMM. Equipment Required You will need the following equipment to complete the performance verification...
  • Page 55 WARNING The following servicing instructions are for use only by qualified personnel. To avoid injury, do not perform any servicing other than that stated in the operating instructions unless you are qualified to do so. Refer to all Safety Summaries before performing any service.
  • Page 56 Service Strategy The service procedures in this manual provide removal and replacement procedures to repair the VX1411 Mainframe to a module level. Instrument level repairs are accomplished by exchanging faulty modules with known-good modules or parts. No component-level repair is provided in this manual.
  • Page 57 To confirm this, inspect the mainframe for physical damage incurred during transit. Retain the mainframe packaging in case shipment for repair is necessary. If there is damage or deficiency, contact your local Tektronix representative. Cleaning procedures consist of exterior and interior cleaning of the mainframe and cleaning the fan filter.
  • Page 58: Figure 6-1: Removing The Fan Filter

    Clean the fan filter by vacuuming or blowing air through the filter. Rinse the filter in cool water and dry it before replacing it in the mainframe. 6–3 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 59 WARNING. To avoid electric shock, always power off the mainframe and disconnect the power cord before cleaning or servicing the mainframe. Tools Required The following tools are required to disassemble the VX1411 Mainframe to the module level: Small flat blade screwdriver...
  • Page 60: Figure 6-2: Location Of Fan Assembly Screws On The Rear Of The Mainframe

    8-32 Captive screw 8-32 Captive screw 8-32 Captive screw Figure 6–2: Location of fan assembly screws on the rear of the mainframe 6–5 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 61: Figure 6-3: Removing The Fan Assembly

    Fan cables Fan assembly Figure 6–3: Removing the fan assembly Fans Cable tie 6-32 Screws (6) Fan assembly Figure 6–4: Removing the fans 6–6 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 62: Figure 6-5: Removing The Fan Control Board

    Interface board. This step is normally not necessary because the Power Supply and the Power Supply Interface board can be replaced as a single unit. 6–7 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 63: Figure 6-6: Removing The Power Supply Interface Board

    3. Refer to Figure 6–6 and remove the Power Supply Interface board from the power supply module as shown. 8-32 Screws (4) Power supply interface board Figure 6–6: Removing the power supply interface board 6–8 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 64 To replace a card guide, slide the card guide towards the rear of the mainframe and allow the front of the card guide to snap into place. 6–9 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 65: Figure 6-7: Removing The Top And Bottom Card Guides

    Figure 6–7: Removing the top and bottom card guides 6–10 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 66: Figure 6-8: Replacing The Top And Bottom Nut Rails

    Maintenance Procedure 5: Replacing The nut rails at the top and the bottom of the front of the VX1411 Mainframe the Top and Bottom Nut allow the user to securely install the modules in the mainframe by screwing the top and bottom of the modules to the front of the mainframe. Refer to Figure 6–8 Rails to remove these nut rails.
  • Page 67 4. After removing all screws from the backplane, remove the backplane from the mainframe by sliding it out of the right side. Install the backplane by reversing the disassembly procedure. 6–12 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 68: Figure 6-9: Removing The Backplane

    Maintenance Power switch connector 6-32 Screws (17) Backplane Figure 6–9: Removing the backplane 6–13 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 69: Table 6-1: Fuses

    Oscilloscope, 20 MHz BW, with 10x Probe (Tektronix TDS400A or TDS500A series oscilloscope) Diagnostic Information The VX1411 Mainframe does not include diagnostics. The functionality of the mainframe can be verified by following the performance verification procedures as described in Performance Verification beginning on page 5–1.
  • Page 70 IntelliGuides (shutters). Repackaging Instructions If you need to send the VX1411 Mainframe to a Tektronix field center for repair, attach a tag to the mainframe with the owner name and address, the serial number, and a brief description of the problem(s) encountered or the service required.
  • Page 71 Maintenance The VX1411 Mainframe contains the following major components: Power supply Backplane Fan Control board Power Supply. The power supply provides all voltages and currents to the mainframe. The power supply connects to the backplane at J1 and J2 through the Power Supply Interface board.
  • Page 72: Figure 6-10: Mainframe Block Diagram

    The two fans connect to the fan control board at J7 (Fan2) and J8 (Fan1). The Fan Speed switch (S1) selects either low fan speed (LOW) or full speed (FULL). 6–17 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 73 Replaceable Parts This section contains a list of the replaceable modules for the VX1411 Main- frame. Use this list to identify and order replacement parts. Parts Ordering Information Replacement parts are available through your local Tektronix field office or representative.
  • Page 74: Table 7-1: Vx1411 Mainframe Common Replaceable Parts

    Modules can be serviced by selecting one of the following two options. Contact your local Tektronix service center or representative for repair assistance. Module Repair and Return. You may ship your module to Tektronix, Inc. for repair, after which we will return it to you.
  • Page 75: Table 7-2: Parts List Column Descriptions

    Using the Replaceable Parts List This section contains a list of the mechanical and/or electrical components that are replaceable for the VX1411 Mainframe. Use this list to identify and order replacement parts. The following table describes each column in the parts list.
  • Page 76 14150 SW KARL BRAUN DR BEAVERTON OR 97077–0001 PO BOX 500 8X345 NORTHWEST SPRING MFG CO 5858 SW WILLOW LANE LAKE OSWEGO, OR 97035 7–4 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 77 CABLE ASSY,PWR,3,16 AWG,2.5 METER,GREY, 13A/250V 0B445 ECM–161–0213–00 159–0397–00 FUSE,CARTRIDGE:5 X 20MM, 4A, 250V, CER 75915 215004 200–2265–00 CAP,FUSEHOLDER:5 X 20MM FUSES 61935 031.1663 7–6 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 78 Replaceable Parts Figure 7–1: Cabinet and Chassis Assembly 7–7 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 79 PANEL,FRONT:SINGLE WIDE BLANK VXI, EMI GASKET TK1943 333409200 2–12 333–4169–00 PANEL,FRONT:DOUBLE WIDE BLANK, STANDARD 80009 333416900 2–13 333–4170–00 PANEL,FRONT:SINGLE WIDE BLANK, STANDARD 80009 333417000 7–8 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 80 Replaceable Parts Figure 7–2: Circuit Boards and Chassis Parts 7–9 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 81 AIR FILTER:WOVEN POLYPROPYLENE,BLACK,0.125 THICK, 80009 378207500 2 LAYER,VINYL EDGING –15 211–0846–00 SCREW:SCREW,SHLDR,6–32 X 0.156,HEX SOCKET 51506 67515–S–12–VT SHOULDER SCREW,0.156 DIA X 0.125 SHANK 7–10 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 82 Replaceable Parts Figure 7–3: Power Supply and Fan Assembly 7–11 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 83 407–4363–00 BRACKET:RACKMOUNT,2R 80009 407436300 –4 212–0671–00 SCREW,MACHINE:10–32 X 0.625,FLH,100 DEG,STL,CDPL, 0KB01 ORDER BY DESC TORX –5 351–0800–00 GUIDE,SLIDE:CHASSIS TRACK, (PAIR) 06666 CTS–424 7–12 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 84 Replaceable Parts Figure 7–4: 1R Rackmount Assembly 7–13 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 85 SCREW,MACHINE:8–32 X 0.375,PNH,STL,CD PL,T–20 0KB01 ORDER BY DESC –8 200–4243–01 DOOR ASSY:LEXAN DOOR,W/LATCH HARDWARE 80009 200424301 ATTACHED –9 351–0800–00 GUIDE,SLIDE:CHASSIS TRACK, (PAIR) 06666 CTS–424 7–14 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 86 Replaceable Parts Figure 7–5: 2R Rackmount and Door Assembly 7–15 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 87 212–0158–00 SCREW,MACHINE:8–32 X 0.375,PNH,STL,T–20 0KB01 ORDER BY DESCRIPTION –2 333–4158–00 PANEL,CONN:0.09ALUM 0J9P4 333–4158–00 –3 407–4361–00 CABLE TRAY:0.09 ALUMINUM,PAINTED SMOKE TAN 0J9P4 407–4361–00 7–16 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 88 Replaceable Parts Figure 7–6: Option 1U Cable Tray 7–17 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 89 Appendix A: Power Budget Worksheet Use the Power Budget Worksheet to determine the operating parameters of the VX1411 Mainframe and any installed modules. Enter the steady-state cur- rent (I ) and the dynamic current (I ) for each module. Add the individual currents to determine the total current needed for each power rail.
  • Page 90 –12V +24V –24V –5.2V –2V Slot Module Total Current of All Modules VX1411 Current Limit Individual Current Sums Less Than VX1411 Current Limits? Power Calculation (V x total Total Power < 500W Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 91 Butch Plate A connector plate that optionally connects to the rear of the cable tray options. The plate can be modified to accept cable connectors thus reducing the number of cables under the VX1411 Mainframe. Glossary–1 VX1411 MainFrame Instruction Manual...
  • Page 92 P1 on the VMEbus. C-Size Card A VXIbus instrument module that is 340.0 233.4 mm 30.48 mm (13.4 9.2 in 1.2 in). Glossary–2 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 93 Any self test or diagnostic power-on routine that executes after the initial kernel self test program. External System Controller The host computer or other external controller that exerts overall control over VXIbus operations. Glossary–3 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 94 Also, one device may require more than one instrument module. IntelliGuides The card guides used in the VX1411 Mainframe. The card guides on the bottom of the mainframe shut off airflow when no modules are installed in the respective slots.
  • Page 95 The bottom backplane connector for a given module slot in a vertical C-size mainframe such as the VX1411; or the middle backplane connector for a given module slot in a vertical D-size mainframe.
  • Page 96 1 through 12 (CLK10 and the module identity lines), but that may provide other services such as CLK100, SYNC100, STARBUS, and trigger control. See Shared Memory Protocol. Glossary–6 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 97 ID-ROM, and reporting such errors to the Resource Manager. Test Program A program, executed on the system controller, that controls the execution of tests within the test system. Glossary–7 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 98 A 100 MHz, 100 ppm clock synchronized with CLK10. Also see CLK100. 488-To-VXIbus Interface A message based device that provides for communication between the IEEE-488 bus and VXIbus instrument modules. Glossary–8 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 99 4–9 diagnostics, 6–14 module selection guidelines, 1–17 disassembly procedures, 6–4–6–13 tools required, 6–4 nut rails, 6–11 removing, 6–11 EMI configuration, 1–20 Index–1 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 100 6–4–6–13 tools required, 6–4 upgrade kits, 1–2 safety ground, 2–2 VXI compliance, 4–11 safety specifications, 4–6 VXIplay&play compliance, 4–11 secondary power, 4–2 Index–2 VX1411 MainFrame Instruction Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...

Table of Contents