Download Print this page

Advertisement

Quick Links

L86
EMR/EMAR
e l e c t r o n i c s m o d u l e
U S E R M A N U A L
Electronic Theatre Controls
North America
3030 Laura Lane
Middleton, Wisconsin 53562 • USA
Tel: (+1) 608 831 4116 • Fax: (+1) 608 836 1736 Tel: (+44) 181 896 1000 • Fax: (+44) 181 896 2000 Tel: (+852) 2799 1220 • Fax: (+852) 2799 9325
World Wide Web http://www.etcconnect.com • Email mail@etcconnect.com
This manual describes ETC's L86 EMR and EMAR electronics receiver modules. These two
L86 components are almost identical, the difference lying in the EMAR's ability to translate
multiple data formats. The EMR can only accept DMX512 control signal.
The EMR/EMAR electronics module is installed in the top center slot of the L86 dimmer
chassis. It receives dimmer output data from a lighting control console, then distributes
the data in DMX512 format to the rack's EM64 electronics modules.
ETC configures the EMR/EMAR to customize the dimmer numbering within the chassis.
This allows chassis starting addresses other than the normal multiple of 48. The module
compensates for a mixture of dimmer types within the same chassis and can customize
the control curve for each dimmer. It can also be set by ETC to allow two consoles to
control two sets of lights independently, or two consoles to control the same lights with
highest level taking priority.
Generally, EMR/EMARs within installation racks are configured at ETC to match the
requirements of your system. For portable applications, standard configurations are
available without custom programming. For more details about standard and custom
configurations, see Configuring the EMR/EMAR on page 3.
Front panel
Electronic Theatre Controls, Inc.
The EMR/EMAR front panel is illustrated above. It contains eight lettered indicator LEDs,
a power LED, a [Reset] button, and a fuse holder.
Europe
5 Victoria Industrial Estate • Victoria Road
London W3 6UU • England
Turn to remove
+5V A B C D
E F G
H
Asia
Room 1619-20 • 16/F Metro Centre II • 21 Lam Hing Street
Kowloon Bay • Hong Kong
Copyright 1992-96. Specifications subject to change. Revised 3/92. 1086M1010
Reset
Fuse
Type 3AG-1

Advertisement

loading

Summary of Contents for ETC L86 EMR

  • Page 1 It can also be set by ETC to allow two consoles to control two sets of lights independently, or two consoles to control the same lights with highest level taking priority.
  • Page 2 System is receiving power Note: If all LEDs flash simultaneously, the system has encountered a condition that makes it impossible to function. Please contact ETC customer service at 608/831-4116 if this happens. See Backup Jumpers on page 4 for more information.
  • Page 3 1 2 3 4 5 6 7 8 separate sheet noting your actual settings. If you have any questions, please contact ETC Technical Service at 608/831-4116. The modules are configured by adjusting settings on a bank of jumpers within the module.
  • Page 4 3 and 4. Customized modules may have different settings, but you should never need 1 2 3 4 5 6 7 8 to change the settings on these jumpers except as instructed by ETC Technical Service. Setting descriptions are based on module oriented as shown in the illustrations to the left.

This manual is also suitable for:

L86 emar