Empire eOne Series Operating And Maintenance Instructions Manual

Metering pumps

Advertisement

Quick Links

Product & Chemical Disclaimer
The user must take responsibility in the selection of the products materials of construction. Empire
Pumps Ltd will act in an advisory role and offer recommendations; however, the user is liable for the
product selection in line with solutions and temperatures in which the equipment is operated.
Safety Precautions
WARNING: Prior to operating the pump read and understand the operating and maintenance
instructions.
WARNING: Ensure the pump is compatible with the fluids and temperatures being transferred. Always
consult Empire Pumps Ltd if there is any change in chemical concentrations or solution temperatures.
WARNING: Wear protective eye and personal equipment at all times when operating the pump. Follow
standard safety procedures when handling corrosive or harmful solutions.
WARNING: Ensure all operators of this equipment have been trained for safe working practices,
understand its limitations and wear safety goggles and equipment at all times.
WARNING: Correct procedures must be followed to drain the pump of all chemistries prior to physical
inspection of the pump.
WARNING: Excessive Pressure. Can result in serious injury or equipment damage. Do not service or
clean the pump whilst the system is pressurised. Relieve pressure from the system prior to
disassembly.
WARNING: Never operate the pump above the specified maximum operating pressure of the pump.
WARNING: Suction and discharge connections must be compatible with the solutions being pumped
and the maximum pressure capability of the pump.
WARNING: Maximum temperatures are based on mechanical stress only. Certain chemicals will
significantly reduce the maximum operating temperature of the pump materials. Consult with the
chemical manufacturer and Empire Pumps Ltd for solution compatibility and temperature limitations.
WARNING: The pump must not be used as structural support to the piping system. Ensure suction and
discharge pipe-work are independently supported to avoid stress on the pump parts.
WARNING: Use only Empire Pumps Ltd genuine spare parts to assure compatible pressure rating and
longest service life.
WARNING: Re-torque all fasteners before operation. Excessive torque is unnecessary and may cause
damage to the pump.
WARNING: Upon receipt of the pump, inspect for any signs of shipping damage. If damage has
occurred contact Empire Pumps Ltd.
Operating and Maintenance Instructions
www.empirepumps.com
Page 1 of 35
Metering Pumps

Advertisement

Table of Contents
loading

Summary of Contents for Empire eOne Series

  • Page 1 Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however, the user is liable for the product selection in line with solutions and temperatures in which the equipment is operated.
  • Page 2: Important Checks

    WARNING: Magnetic field. Keep the magnets away from metal chips and items such as credit cards, discs and magnetic tapes inside computers and mobile phones. WARNING: Flammable or Combustible Liquids: Please immediately consult Empire Pumps Ltd if the solutions being transferred are flammable. The pumps detailed in this operating and maintenance instructions cannot be used in explosive atmospheres.
  • Page 3 Metering Pumps Operating and Maintenance Instructions Once the packaging has been removed, check the pump, and if in doubt do not use the pump and consult with qualified personnel. The packaging materials (such as plastic bags, polystyrene, etc..) must not be left within reach of children as they are potential sources of danger. Before connecting the pump, make sure that the data on the plate corresponds to that of the power distribution network.
  • Page 4 Metering Pumps Operating and Maintenance Instructions Failure to comply with these conditions may compromise the proper operation of the pump. The nameplate data is shown on the adhesive label attached to the pump. • In the event of damage to the pump power cable, ask for it to be replaced by our service centres or qualified personnel to prevent risks for the people who use it;...
  • Page 5 Metering Pumps Operating and Maintenance Instructions The material to be sent to the factory for maintenance should be disassembled and packed carefully; all the parts in contact with the chemical must be emptied and rinsed to ensure the safety of the operators while transporting and handling the material in the laboratory.
  • Page 6 Metering Pumps Operating and Maintenance Instructions • Environmental conditions: indoors, maximum altitude 2000 m, room temperature from 5 ° C to 40 ° C, maximum relative humidity 80% up to a maximum of 31 ° C (decreasing linearly until it is reduced to 50% at 40°C) •...
  • Page 7 Metering Pumps Operating and Maintenance Instructions The pump doses in proportion to a 4-20 mA current signal coming from an PROPORTIONAL external transducer. The setting of maximum and minimum values can be set from mA input in the respective set-up menu. Additional functional principles Function Description...
  • Page 8 The pump is equipped with a power supply board that regulates the power absorbed as a function of the operating pressure (excluding the BASIC series). The following table shows the technical features of the eOne series and the corresponding flow curves: Type...
  • Page 9: Installation

    Metering Pumps Operating and Maintenance Instructions Installation Introduction This section describes the steps for installing the pump, the pipes, and the electrical wiring. Read these instructions carefully before beginning any activity. Follow these guidelines when installing the pump. • Ensure that the pump and all related equipment is turned off before starting work. •...
  • Page 10 Metering Pumps Operating and Maintenance Instructions Electrical connection Comply with the rules in force in the various countries with respect to the electrical installation. If the power cable is devoid of a plug, the equipment must be connected to the mains supply via a double pole isolator switch with a minimum distance between contacts of 3 mm.
  • Page 11 Metering Pumps Operating and Maintenance Instructions To prime the pump, connect the discharge tubing and follow the sequence shown in Figure 5. • unscrew the bleeding knob, with the pump running, • keep the bleed valve B open until all the air contained in the tube and in the pump body comes out, •...
  • Page 12 Metering Pumps Operating and Maintenance Instructions 1. plant to be treated 2. 3/8 "- ½" conical connection 3. injection valve 4. locking ring for pipe connection 5. pump flow tube 6. PTFE tape Fig. 7 - Connection assembly Installation Kit The following is supplied with the pump: •...
  • Page 13 Metering Pumps Operating and Maintenance Instructions • During the countdown pressing and holding down START/STOP the pump starts to give injections to reach the right dosing condition to existing system pressure. We recommend that you use this procedure to return the pump in optimal working condition especially if it operates at any proportional mode. During this phase, you should close of the bleed valve on the pump body.
  • Page 14 Metering Pumps Operating and Maintenance Instructions Start and Stop Button Button to scroll the menu to the right, increase values Button to scroll through the menus to the left, decrease values Button access to submenus, scroll down the menu below, to CONFIRM your choice Button to scroll up the submenu Yellow LED flow status alarm / power failure alarm / maximum acceptable impulse difference alarm...
  • Page 15 Metering Pumps Operating and Maintenance Instructions For accurate metering, in the eOne and MF Plus models we have implemented the option to automatically or manually set the actual flow rate for each injection. The following describes the practices that must be observed for "AUTOMATIC"...
  • Page 16 Metering Pumps Operating and Maintenance Instructions Proportional 1XN (VFT, MF, VFT- T, MF -T) The pump is provided with a connector for connection to an external water meter which can provide a series of contacts proportional to the amount of liquid that must be treated. A flashing dot on the display shows the input impulse from the meter.
  • Page 17 Metering Pumps Operating and Maintenance Instructions % SOLUTION Generally the additive to be dosed by the pump is part of an aqueous solution in a specified percentage. Set this value using the special arrow keys of the keyboard:1–100% ml x m SET3 set the value in ml x m3 which must be guaranteed in the plant.
  • Page 18 Metering Pumps Operating and Maintenance Instructions In relation to the system requirements, the pump allows you to determine whether Under mA (1) SET 1: to continue or terminate the metering when the measurement takes on a current value below the set point 1 (SET1). In relation to the system requirements, you can define whether to continue Above mA (2) SET 2: or terminate the metering when the measurement has a current value above the...
  • Page 19: Flow Diagram Settings Menu

    Metering Pumps Operating and Maintenance Instructions Flow Diagram Settings Menu Some menu items are only present in the proportional or control versions, as shown in the box next to the  blocks. To access the items of the Setting Sub-menus press the button www.empirepumps.com Page 19 of 35...
  • Page 20 Metering Pumps Operating and Maintenance Instructions Flow Diagram MODE: REMOTE/LEVEL, RELAY ACTIVATION, FLOW RATE PER IMPULSE, MAX FREQUENCY, ALARMS SETTINGS www.empirepumps.com Page 20 of 35...
  • Page 21 Metering Pumps Operating and Maintenance Instructions Flow Diagram MODE: CLOCK, PASSWORD, LANGUAGE, RESET www.empirepumps.com Page 21 of 35...
  • Page 22 Metering Pumps Operating and Maintenance Instructions Functions Accessories of the Multifunction Pump In order to facilitate the consultation of this manual, the configuration with the function described is shown in the subsection titles. Nothing is specified when the function is common to all versions. Remote Control - Level Remote control means the ability to remotely control any device by means of a cable, in our case bipolar;...
  • Page 23 Metering Pumps Operating and Maintenance Instructions Clock In some applications, there may be the need to program the activation or deactivation of the pump, which is why the electronic device is equipped with a clock and calendar. The following settings can be carried out: CLOCK hh:mm –...
  • Page 24 Metering Pumps Operating and Maintenance Instructions Operational Functions of the Multifunction Pump Flow Diagram MODE: MANUAL, 1xN, 1xN(M) 1:N, ml x P, l x P, ml x m 3 , PPM www.empirepumps.com Page 24 of 35...
  • Page 25 Metering Pumps Operating and Maintenance Instructions Flow Diagram MODE mA Alarms The MF Metering pump has the ability to monitor the proper functioning of the system and signal some alarm situations that may occur. It can specifically detect the following alarms: •...
  • Page 26 Metering Pumps Operating and Maintenance Instructions All alarm conditions are indicated by the lighting of the LED on the control panel and on the display. The switching of the alarm relay also occurs (contacts 19, 20 and 21 fig.9) if enabled, where applicable, by the different configuration menus.
  • Page 27 Metering Pumps Operating and Maintenance Instructions injections to be yet delivered is shown in dynamic mode. The choice of factor 4 is an easy way to prevent any transient phenomena generating false alarms. If the activation of this alarm is frequent it is recommended that the operator checks the operating conditions of the plant.
  • Page 28 Metering Pumps Operating and Maintenance Instructions Flow Diagram Alarm Settings Menu Flow Diagram ALARM MENU: LEVEL, FLOW METER www.empirepumps.com Page 28 of 35...
  • Page 29 Metering Pumps Operating and Maintenance Instructions Flow Diagram ALARM: W.M.METER, ppm, ml x m3, UNDERLOAD, OVERLOAD www.empirepumps.com Page 29 of 35...
  • Page 30: Programmable Timer Function Daily And Weekly

    Metering Pumps Operating and Maintenance Instructions Programmable Timer Function Daily And Weekly The TIMER settings menu is present in the configurations VFT-T VFT-ST, MF-T and ST-T. The Timer menu function allows you to manage the operating status of the metering pump over all the set functions. The timer is structured in such a way that you can have 16 start cycles in a day (Pump On) and Stop (Pump not operating).
  • Page 31: Routine Maintenance

    Metering Pumps Operating and Maintenance Instructions Routine Maintenance Thorough routine maintenance, together with a scheduled inspection, ensures preservation and good functioning of the systems over time. We therefore recommend you follow our routine maintenance advice and enter into a programmed service and assistance contract with a trusted Technical Support Centre.
  • Page 32 Metering Pumps Operating and Maintenance Instructions In the event of maintenance and/or technical work, always make sure that the pump is disconnected from the electrical mains and that you are wearing protective clothing and equipment (gloves and safety goggles). FAULT SOLUTION The pump is not metering •...
  • Page 33: Warranty

    (see RESET chapter) Warranty Empire Pumps Ltd warrants this pump product to be free of defects in materials and workmanship for a period of two years from the purchase date. It does not cover installation or system design faults, pumps seized due to deposits or damaged packaging and Empire Pumps Ltd is not liable for consequential losses.
  • Page 34: Declaration Of Conformity

    The conformance is valid only if the pump is used for the liquids communicated by the customer and for the pump characteristics required with regard to the quotation. Empire Pumps Ltd does not take any responsibility for its pumps unless the customer operates the equipment strictly in accordance with the operation and instruction manual.
  • Page 35 Metering Pumps Operating and Maintenance Instructions www.empirepumps.com Page 35 of 35...

Table of Contents