INSTALLATION REQUIREMENTS

Follow All State and Local Codes.
Each HotPod
must be supplied with a dedicated 120 volt AC circuit, 15A for 1000W models, 20Amp for 1440W
TM
models. Use 14 ga. copper wire MINIMUM.
For indoor use ONLY with 6" or 8" round ductwork (depending on model).
Units are rated for zero clearance.

CHOOSE LOCATION (Figure 1)

1. Install HotPod

in a horizontal position ONLY.
TM
2. Select a 14" (35.6 cm) section of duct that is a MINIMUM of 4 feet (122 cm) from outlet register.
Select section so that you can insert male crimped end into inlet side of the HotPod
Discharge end must point toward outlet register (arrows show air flow direction).
Position wiring enclosure to allow permanent access to the wiring compartment.
INSTALL HotPod
TM
1. Remove 9" (22.9 cm) section of duct for the 6" HotPod or 9 1/2" for the 8" HotPod. Allow an additional 5" (12.7cm) for
the optional Silent Boot.
For Rigid Metal Duct
Crimp ends of the duct as needed to provide male ends for insertion into the HotPod
Fasten with a minimum of 3 sheet metal screws at both ends and within 1.5" (3.8 cm) of the end of the housing. Seal
with a good quality duct tape.
For Flexible Duct
Attach flexible duct directly to HotPod
HotPod
TM
EHP8-14402CT
housing using approved connection methods.
TM
1 of 4
ECO 1-7639 60220 REV.-
INSTALLATION
INSTRUCTIONS
.
TM
TM.
FORM: 8224

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HotPod EHP6-10002CT and is the answer not in the manual?

Questions and answers

Summary of Contents for TPI Corporation HotPod EHP6-10002CT

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION HotPod INSTRUCTIONS MODELS: EHP6-10002CT EHP8-14402CT Patent No’s.: US 8,285,127; 8,625,976; 8,787,738: 8,837,922 INSTALLATION REQUIREMENTS Follow All State and Local Codes. • Each HotPod must be supplied with a dedicated 120 volt AC circuit, 15A for 1000W models, 20Amp for 1440W models.
  • Page 2 Fig. 1 A. Cut out the required amout from the duct (see INSTALL HotPod for dimensions). B. MINIMUM 4 feet (122cm) from outlet register. C. Wiring cover D. Fasten with 3 sheet metal screws both ends. E. Insert male crimped end. F.
  • Page 3 THERMOSTAT INSTALLATION FOR ‘HARD-WIRED’ THERMOSTATS Note: All thermostats may not operate the HotPod correctly. The thermostat must operate the fan with the heat. CONTROL WIRING The HotPod is provided with a low voltage wall thermostat 1. Disconnect the power supply to the HotPod. 2.
  • Page 4 THERMOSTAT INSTALLATION INSTRUCTIONS Determine the location where the thermostat is to be mounted. It should be installed about 54” above floor level where there is good air circulation. Avoid heat sources such as lamps,direct sunlight, fireplaces or walls containing air conditioning and heating ducts.

This manual is also suitable for:

Hotpod ehp8-14402ct

Table of Contents