Hubbell GAI-TRONICS TempSense TS200 Manual
Hide thumbs Also See for GAI-TRONICS TempSense TS200:

Advertisement

Quick Links

TempSense Models TS200/TS200W
Confidentiality Notice .....................................................................................................................1
General Information .......................................................................................................................1
Installation ......................................................................................................................................2
Camera Location ..................................................................................................................................... 2
Wall Mount ........................................................................................................................................... 3
Pole Mount ............................................................................................................................................ 3
VESA Mount ........................................................................................................................................ 3
Stand Mount .......................................................................................................................................... 4
Connection ............................................................................................................................................... 4
Model TS200 ........................................................................................................................................ 4
Model TS200W ..................................................................................................................................... 4
Configuration ..................................................................................................................................5
TempSense TS200 ................................................................................................................................... 5
TempSense TS200W ............................................................................................................................... 5
Calibration ............................................................................................................................................... 7
Operation .........................................................................................................................................8
Environment ............................................................................................................................................ 8
Subject Preparation ................................................................................................................................ 8
Scanning Subjects ................................................................................................................................... 8
Specifications ..................................................................................................................................9
Electrical .................................................................................................................................................. 9
Mechanical ............................................................................................................................................... 9
FLIR Camera .......................................................................................................................................... 9
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 ◼ 800-492-1212 ◼ Fax: 610-796-5954
V
ISIT WWW
G A I - T R O N I C S
A H U B B E L L C O M P A N Y
T
A B L E O F
.
-
.
GAI
TRONICS
COM FOR PRODUCT LITERATURE AND MANUALS
®
C
O N T E N T S
Pub. 42004-566A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAI-TRONICS TempSense TS200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hubbell GAI-TRONICS TempSense TS200

  • Page 1: Table Of Contents

    Pub. 42004-566A G A I - T R O N I C S ® A H U B B E L L C O M P A N Y TempSense Models TS200/TS200W A B L E O F O N T E N T S Confidentiality Notice ........................1 General Information ........................1 Installation ............................2...
  • Page 2: Confidentiality Notice

    Pub. 42004-566A G A I - T R O N I C S ® A H U B B E L L C O M P A N Y TempSense Models TS200/TS200W Confidentiality Notice This installation and operation manual contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
  • Page 3: Installation

    Pub. 42004-566A TempSense Models TS200/TS200W Page 2 of 9 Installation : The accuracy of the TempSense TS200/TS200W requires individual subjects pass within two to six feet of the thermal imaging camera lens. Results with different camera positions may vary. Thermal imaging camera accuracy improves as the subject moves closer to the camera. Camera Location Locate the TempSense TS200/TS200W so that people in a queue individually pass through the two cameras’...
  • Page 4: Wall Mount

    Pub. 42004-566A TempSense Models TS200/TS200W Page 3 of 9 Wall Mount Mount the TempSense TS200/TS200W to a wall as follows (see Figure 4): : GAI-Tronics recommends spacing the TempSense Model TS200 approximately ¼ inch from any flat surface to allow air flow. 1.
  • Page 5: Stand Mount

    Pub. 42004-566A TempSense Models TS200/TS200W Page 4 of 9 Stand Mount Mount the TS200/TS200W to a tripod or microphone stand using the included L- bracket (see Figure 8). 1. Secure the mounting plate (TS200: see Figure 6, TS200W: see Figure 7) to the TS200/TS200W using the four included #6-32 screws.
  • Page 6: Configuration

    Pub. 42004-566A TempSense Models TS200/TS200W Page 5 of 9 Configuration The TempSense TS200 and TS200W have a built in webserver for configuration and calibration of the TempSense device. TempSense TS200 Configure the TempSense TS200 before calibrating it or using it to scan subjects: 1.
  • Page 7 Pub. 42004-566A TempSense Models TS200/TS200W Page 6 of 9 6. Configure all settings and click A PPLY HANGES AND ESTART The unit reboots and tries to connect to the configured wireless network. : To reset the TS200W, use a jumper cap to short pins 39-40 on the 40-pin header ACTORY ESET for 5 seconds.
  • Page 8: Calibration

    Pub. 42004-566A TempSense Models TS200/TS200W Page 7 of 9 Table 3. SMTP Parameters Parameter Description Value: username The username for the SMTP server mailbox (string) None the SMTP server’s IP Version 4 address server valid IPv4 address or FQDN (Fully Qualified Domain Name) 0.0.0.0 security SMTP security protocol in use...
  • Page 9: Operation

    Pub. 42004-566A TempSense Models TS200/TS200W Page 8 of 9 Figure 11. Temperature Superposition and Calibration Operation Environment Environmental considerations for the Models TS200/TS200W NCIT (non-contact infra-red thermometer) performance: • Use the temperature scanning feature of the TS200/TS200W in a draft-free space that is out of direct sunlight and away from radiant heat sources.
  • Page 10: Specifications

    Pub. 42004-566A TempSense Models TS200/TS200W Page 9 of 9 Specifications Electrical Power: TS200 ..............................PoE TS200W............................120 V ac Mechanical Dimensions ............. 7.26 H × 5.76 W × 1.5 D in (184.4 × 146.3 × 38.1 mm) Weight ............................2.0 lb (0.9 kg) FLIR Camera Horizontal FOV ............................

This manual is also suitable for:

Gai-tronics tempsense ts200w

Table of Contents