Download Print this page

Samsung ERV RHF025EE Service Manual page 9

Energy recovery ventilator

Advertisement

Product Specifications(cont.)
RHF050EE
Power Source
Ventilation Mode
The Level of the Air Volume
Power Supply(W)
Air Volume(m³/h)
External Static Pressure(mmAq)
Temperature Exchange
Efficiency(%)
Valid Heat Exchange
Efficiency(%)
Size(widthxheightxdepth)(mm)
Weight(kg)
Duct Size(mm)
Air Volume Control Specifications (Turbo)
Trial Operation Conditions
RHF080EE
Power Source
Ventilation Mode
The Level of the Air Volume
Power Supply(W)
Air Volume(m³/h)
External Static Pressure(mmAq)
Temperature Exchange
Efficiency(%)
Valid Heat Exchange
Efficiency(%)
Size(widthxheightxdepth)(mm)
Weight(kg)
Duct Size(mm)
Air Volume Control Specifications (Turbo)
Trial Operation Conditions
2-3
Heat-Ex Ventilation
Turbo
180
500
18.3
Cooling
70
Heating
80
Cooling
50
Heating
70
Range : External Static Pressure 8.0~18.3[mmAq], Power Supply 110.0~180.0[W]
1. Air Volume/ External Static Pressure, Comply with KS Heat Exhaust Ventilation System Standards(KS B6879).
2. Heat Exchange/Temperature Exchange Efficiency, Comply with regulations to pro-
mote high efficiency energy devices,
[Cooling], Indoor(24˚C DB/17˚C WB), Outdoor(35˚C DB/24˚C WB)
[Heating], Indoor(22˚C DB/13.9˚C WB), Outdoor(2˚C DB/0.44˚C WB)
3. Duct length refers to its size when friction loss coefficient stands at 0.02
Heat-Ex Ventilation
Turbo
340
800
17.7
Cooling
70
Heating
81
Cooling
55
Heating
72
Range : External Static Pressure 0.0~17.7[mmAq], Power Supply 160.0~340.0[W]
1. Air Volume/ External Static Pressure, Comply with KS Heat Exhaust Ventilation System Standards(KS B6879).
2. Heat Exchange/Temperature Exchange Efficiency, Comply with regulations to pro-
mote high efficiency energy devices,
[Cooling], Indoor(24˚C DB/17˚C WB), Outdoor(35˚C DB/24˚C WB)
[Heating], Indoor(22˚C DB/13.9˚C WB), Outdoor(2˚C DB/0.44˚C WB)
3. Duct length refers to its size when friction loss coefficient stands at 0.02
AC220V, 60Hz
High
Low
155
130
420
350
13.6
9.5
72
74
82
84
53
56
73
76
1,012x270x1,000
42.5
200
AC220V, 60Hz
High
Low
290
240
700
600
12.4
8.1
71
72
82
83
57
59
74
76
1,220×340×1,135
67
250
By-Pass Ventilation
Turbo
High
180
155
500
420
18.3
13.6
-
-
-
-
-
-
-
-
By-Pass Ventilation
Turbo
High
340
290
800
700
17.7
12.4
-
-
-
-
-
-
-
-
Samsung Electronics
Low
130
350
9.5
-
-
-
-
Low
240
600
8.1
-
-
-
-

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Erv rhf035eeErv rhf050eeErv rhf080eeErv rhf100ee