BEHR KEEP COOL Fitting Instructions Manual

One-sided retrofit for commercial cooler and freezer islands

Advertisement

Quick Links

KEEP COOL
Curve 625, 1-sided
®
KEEP COOL
Curve 1250, 1-sided
®
!
Please read the full fitting instruction
before initiating the installation procedure.
REHAU-BEHR A/S | Bavne Allé 34 | 8370 Hadsten / Denmark | Tel: +45 86 98 28 22 | www.rehau-behr.com | info@rehau-behr.com
KEEP COOL
®
FITTING INSTRUCTIONS
One-sided retrofit
This fitting instruction is exemplified by a KEEP COOL
glass cover with a 3-glass solution, but is valid for KEEP COOL
COOL
Plane in all lengths and with all glass combinations.
®
Please note that there are minor differences between the installation of KEEP
COOL
Curve and KEEP COOL
Plane, as well as between KEEP COOL
®
®
end unit and KEEP COOL
®
Curve against wall.
Differences will be evident from the fitting instruction.
KEEP COOL
Plane 625, 1-sided
®
KEEP COOL
Plane 1250, 1-sided
®
®
Curve 625 2500 mm
Curve and KEEP
®
Curve
®
© REHAU-BEHR A/S.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KEEP COOL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BEHR KEEP COOL

  • Page 1 Plane 1250, 1-sided ® ® Please read the full fitting instruction before initiating the installation procedure. REHAU-BEHR A/S | Bavne Allé 34 | 8370 Hadsten / Denmark | Tel: +45 86 98 28 22 | www.rehau-behr.com | info@rehau-behr.com © REHAU-BEHR A/S.
  • Page 2: Table Of Contents

    1. CONTENTS Contents ....................................2 General Information ................................. 3 Exploded views (KEEP COOL® Curve and KEEP COOL® Plane) ....................4 Frame parts: KEEP COOL Curve .............................. 6 ® Frame parts: KEEP COOL Plane .............................. 7 ® Preparation of the cabinet / end unit ............................8 frame assembly 7.A KEEP COOL...
  • Page 3: General Information

    After installation, please hand over the user manual and the microfibre cloths to the store personnel. Please help us improve our product by sending us an email to aftersales@rehau-behr.com. THANK YOU FOR YOUR COOPERATION. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 4: Exploded Views (Keep Cool® Curve And Keep Cool® Plane)

    3. EXPLODED VIEWS | KEEP COOL® CURVE KEEP COOL® CURVE | End Unit: KEEP COOL® CURVE | Against Wall: Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 5 3. EXPLODED VIEWS | KEEP COOL® PLANE EXPLODED VIEW | KEEP COOL® PLANE: KEEP COOL® PLANE: Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 6: Frame Parts: Keep Cool ® Curve

    4. FRAME PARTS | KEEP COOL CURVE ® Frame parts RAL 7015 103626 104155 103613 103615 104443 104441 103678 103704 RAL 7046 103627 104156 103614 103616 104444 104442 103679 103706 105121 105243 105123 105124 105246 105245 105122 105125 RAL 9005...
  • Page 7: Frame Parts: Keep Cool ® Plane

    5. FRAME PARTS | KEEP COOL PLANE ® Frame parts RAL 7015 103626 104155 103613 103615 104443 104441 103678 103704 RAL 7046 103627 104156 103614 103616 104444 104442 103679 103706 105121 105243 105123 105124 105246 105245 105122 105125 RAL 9005...
  • Page 8: Preparation Of The Cabinet / End Unit

    6. PREPARATION OF THE CABINET / END UNIT +/- 5 mm The handrail must be stable, straight and in level before installation. Clean the handrail thoroughly. The handrail must be very clean to gain optimum strength of tape. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 9 Combine fill strips to even out differences precisely The handrail and the back wall must be the same height. Use fill strips to even out height differences. Connect small height differences, i.e. corners and connections, with tape. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 10: Frame Assembly

    7. FRAME ASSEMBLY 7.A: KEEP COOL CURVE VITRINE MURALE ® Recommended torque = 1,2 Nm (500-800RPM) RAL 7015 103626 100349 RAL 7046 103627 RAL 9005 105121 Recommended torque = 1,2 Nm (500-800RPM) RAL 7015 103615 RAL 7046 103616 RAL 9005...
  • Page 11 104458 RAL 9005 105251 100388 RAL 7015 104455 RAL 7046 104456 RAL 9005 105252 RAL 7015 104441 RAL 7046 104442 RAL 9005 105245 RAL 7015 104443 RAL 7046 104444 100388 RAL 9005 105246 Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 12 105125 Cross profile Cross profile MJ RAL 7015 103704 RAL 7046 103706 RAL 9005 105125 RAL 7015 103678 RAL 7046 103679 RAL 9005 105122 RAL 7015 103704 RAL 7046 103706 RAL 9005 105125 Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 13 RAL 7046 103656 RAL 9005 105149 RAL 7015 104155 RAL 7046 104156 RAL 9005 105243 RAL 7015 103556 RAL 7046 103557 RAL 9005 105126 RAL 7015 103678 RAL 7046 103679 RAL 9005 105122 Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 14 RAL 9005 105150 100211 RAL 7015 103577 100171 Left gable RAL 7046 103578 RAL 9005 105127 Right cover plate Left cover plate Use cover plates if there is a gap at the cover end. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 15: B Keep Cool ® Curve End Unit

    7.B: KEEP COOL® CURVE END UNIT Fill strips Use fill strips to even out height differences between the handrail and the back profile. Recommended torque = 1,2 Nm (500-800RPM) RAL 7015 103626 100349 RAL 7046 103627 RAL 9005 105121 Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15...
  • Page 16 RAL 7046 103658 100349 RAL 9005 105148 RAL 7015 103655 RAL 7046 103656 RAL 9005 105149 RAL 7015 104155 RAL 7046 104156 RAL 9005 105243 RAL 7015 103678 RAL 7046 103679 RAL 9005 105122 Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 17 RAL 7015 103678 RAL 7046 103679 RAL 9005 105122 Fit the gables. 100211 Right gable 100171 100211 Left gable RAL 7015 103575 RAL 7015 103576 RAL 7015 105162 100171 Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 18 Use cover plates if there is a gap at the cover ends. No gap between the covers Make sure there is no gap between the end unit cover and the cover on the island. Install the 2-sided cover first. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 19: C Keep Cool ® Plane (Against Wall And End Unit)

    7.C: KEEP COOL PLANE (AGAINST WALL AND END UNIT) ® Fill strips Use fill strips to even height differences between the handrail and the back profile. Recommended torque = 1,2 Nm (500-800RPM) 103626 RAL 7015 100349 RAL 7046 103627 RAL 9005...
  • Page 20 Recommended torque = 1,2 Nm (500-800RPM) RAL 7015 104155 100349 RAL 7046 104156 RAL 9005 105243 RAL 7015 103678 RAL 7046 103679 RAL 9005 105122 Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 21 RAL 7015 103678 RAL 7046 103679 RAL 9005 105122 AGAINST WALL ONLY: Section assembly: RAL 7015 103556 RAL 7046 103557 RAL 9005 105126 Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 22 RAL 7015 103660 100470 RAL 7015 105141 RAL 7015 103661 RAL 7015 103662 RAL 7015 105143 RAL 7015 103665 RAL 7015 103663 RAL 7015 103666 RAL 7015 103664 RAL 7015 105144 RAL 7015 105142 Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 23 Use cover plates if there is a gap at the cover ends. No gaps between the covers Make sure there is no gap between the end unit cover and the cover on the island. Install the two-sided cover first. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 24: Cover Fitting

    Align one side of the cover with the cabinet / end unit. Attach approx. 20 cm at each section end. Against wall: Centre the frame to match the cabinet sectionsbefore taping the cover. End unit: Centre the frame before taping the cover. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 25 Fully attach one side of the cover. Insert bottom glass in the bottom track. Sliding glass bottom track Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 26 Adjust the frame until glass movement is satisfactory. Then tape approx. 20 cm at each section end on the opposite side.     Tape down the remaining sides. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 27 Insert the remaining bottom glasses. Sliding glass bottom track Insert all middle glasses. Sliding glass middle track Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 28 Fit bump-ons on the back profile. 104145 104145 104145 104145 104145 104145 104145 104145 104145 Place all top glasses firmly against the back profile. Top glass top track Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 29: Adjustments

    Remove the protective film from the tape on the top glasses and attach them firmly in the top track of the cross profiles. The tracks must remain parallel. 9. ADJUSTMENTS If glass movement is not optimum, the glasses can be rearranged. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...
  • Page 30 Glass movement can further be optimised by adjusting the sides of the sliding shoes, using a smooth file. Montagevejledning KEEP COOL 1-sidet, v.1.1, 11/15 ®...

Table of Contents