Do you have a question about the IntelliPack 812A Series and is the answer not in the manual?
Questions and answers
Summary of Contents for Acromag IntelliPack 812A Series
Page 1
(217) 352-9330 | Click HERE Find the Acromag 811A-0200 at our website:...
Page 2
Wixom, MI 48393-7037 U.S.A. Tel: (248) 624-1541 Fax: (248) 624-9234 Copyright 1997, Acromag, Inc., Printed in the USA. Data and specifications are subject to change without notice. 8500-562-K04J008 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The information contained in this manual is subject to change is involved. It is important that the user employ satisfactory without notice. Acromag, Inc., makes no warranty of any kind overall system design. It is agreed between the Buyer and with regard to this material, including, but not limited to, the Acromag, that this is the Buyer's responsibility.
Other functions are possible--please consult the factory. mechanical relay, or two Single-Pole-Double-Throw (SPDT) electromechanical relays, for switching voltages to 230VAC An optional AC current sensor (Acromag Model 5020-350) is at currents to 5A. used in conjunction with the DC current input circuit of the •...
For repairs to a product damaged in IntelliPack Cable (Model 5030-902) shipment, refer to the Acromag Service Policy to obtain return instructions. It is suggested that salvageable shipping cartons This 6-wire cable is used to connect the SPI port of the and packing material be saved for future use in the event the IntelliPack Serial Port Adapter to the IntelliPack.
DC milliampere signal to the module. is accomplished with Acromag’s user-friendly Windows 95 This allows the module to be mounted remote from the AC Configuration Program & Serial Port Adapter. Configuration is signal and sensor, and connected using small gauge wire.
(see Table 6). The unit is ready to The alarm module needs to be configured for your accept the second parameter for the relay shown in Table 5: application. Alarm configuration is done using Acromag’s 7. Adjust the input source(s) to the desired level. ...
Alarms are color coded with a yellow label. The prefix “8” returned to Acromag for repair. The board may be damaged denotes the IntelliPack Series 800, while the “A” suffix specifies unless special SMT repair and service tools are used. Further, that outputs are alarm contacts.
AC current signals approximately 24mA, one per input. For use with two-wire (Acromag Model 5020-350). This sensor generates a DC process current transmitters. milliampere signal of 0 to 11.17mA for the module (see Table 2 for scaling to AC current).
IntelliPack Series 812A/811A Alarm User's Manual Dual & Single DC Voltage/Current Inputs ___________________________________________________________________________________________ Expected Mechanical Life: 20 million operations. Table 8: Supply Current Versus Voltage Note: External contact protection is required for use with Supply Maximum Supply Current inductive loads (see Contact Protection Drawing 4501-625). Voltage 812A-0200 811A-0200...
IntelliPack Series 812A/811A Alarm User's Manual Dual & Single DC Voltage/Current Inputs ___________________________________________________________________________________________ Module Push Buttons (See Dwg 4501-631 for Location): Input 1 & Input 2 Configuration Mode - Used to change mode of field configuration. Input - Range: The alarm input can be configured to accept any of the input ranges described in the Input Specifications using Set - Used to accept input data during field calibration.
Page 12
IntelliPack Series 812A/811A Alarm User's Manual Dual & Single DC Voltage/Current Inputs ___________________________________________________________________________________________ Rate-of-Change: The relay will enter the alarm state when Relay - Reset: Relays may be configured to automatically reset the programmed rate-of-change threshold value is when inputs retreat past their setpoints and deadband, or exceeded by the input signal’s rate-of-change for a 1 relays may latch into their alarm state.
MODEL 811A-0100 - SINGLE INPUT SINGLE RELAY RELAY 1 RELAY 1 FUNCTION SINGLE DPDT CONFIGURATION PORT INPUT 1 INPUT SCREW TERMINAL NUMBER RJ11, 6 CONDUCTOR OUTPUT MODEL 811A-0200 - SINGLE INPUT DUAL RELAY ISOLATION 2-WIRE XMTR RELAY 1 EXC+ EXCITATION RELAY 1 FUNCTION RELAY 1 SINGLE...
Digital Process Variable Input 1 (PV-1) Alarm Operating Functions: Engineering Units: Limit Alarm Volts DC, Milliamperes DC Window Alarm Amps AC (with AC Amp Sensor) ON/OFF Controller Reading on PC Monitor Peak/Valley Alarm Configuration Variables: Rate of Change Alarm High or Low Limit Alarm Digital Process Variable Input 2 (PV-2) Relay Alarm Delay Key Alarm Parameters:...
PC, INTEL 486 OR HIGHER PROCESSOR RUNNING WIN95 OR WIN NT. ATTACH ADAPTER TO COM1 OR COM2 ON THE PC. PC RUNNING COM PORTS ARE SOFTWARE CONFIGURED. POWER 10 TO 36VDC ACROMAG CONFIGURATION SOFTWARE RUN/PWR LED (GREEN) Acromag STATUS LED (YELLOW) RELAY 1 LED (YELLOW)
TB1/TB2 EXC+ RELAY CONTACTS CONTACTS ARE SHOWN IN EARTH DE-ENERGIZED CONDITION GROUND CURRENT (mA) SHLD Acromag RUN/PWR LED (GREEN) STATUS LED (YELLOW) DC CURRENT EARTH GROUND RELAY 1 LED (YELLOW), NOTE 1 RELAY 2 LED (YELLOW) N.C. N.O. RELAY 1...
BLACK ONLY. 0 TO 2A SHLD AC CURRENT 0 TO 1A SENSOR FIGURE 3 EARTH GROUND DO NOT CONNECT ACROMAG MODEL 5020-350 AC CURRENT SEE NOTE 1 AC CURRENT DIRECTLY 20 AMPS DANGER: FULL-SCALE TO INPUT TERMINALS. (1-TURN) HIGH VOLTAGE...
Need help?
Do you have a question about the IntelliPack 812A Series and is the answer not in the manual?
Questions and answers