Download Print this page

DARLEY ZSP Nstallation, Operation, Maintenance, Repair And Troubleshooting Instructions page 36

Fire pump

Advertisement

TEST
No.
GPM
1
1750
2
1225
3
875
4
1750
1
2000
2
1400
3
1000
4
2000
1
2250
2
1575
3
1125
4
2250
Min. discharge pressures listed above are for pumps operating with full 10' static suction lift. These
pressures must be increased by 1 PSI for each 2.3 ft. less than 10' of lift.
Prepared by: CJC
Approved by: WAH
Revised by: CWY
TABLE NO. 1
NFPA 1901 TEST
Class A
Recom-
Min.
mended
Nozzle
Nozzles
Press. PSI
1750 GPM Fire Pump
(2), 2"
or
55
(3), 1-1/2"
76
(2), 1-5/8"
61
or
(2), 1-1/2"
84
or
(3), 1-1/4"
79
(1), 2"
or
55
(2), 1-3/8"
61
(2), 2"
55
or
(3), 1-1/2"
76
2000 GPM Fire Pump
(2), 2"
71
or
(4), 1-1/2"
57
(2), 1-3/4"
60
or
(3), 1-1/2"
49
(1), 2"
71
or
(2), 1-1/2"
57
(2), 2"
71
or
(4), 1-1/2"
57
2250 GPM Fire Pump
(2), 2-1/4"
56
(2), 1-3/4"
76
(2), 1-1/2"
72
(2), 2-1/4"
56
Min.
Min. Net
Disch.
Pump
Press. PSI
Press. PSI
143
150
194
200
245
250
158
165
147
150
199
200
249
250
163
165
144
150
196
200
246
250
153
165
3
Disch.
Suction
Lines
Hose
(4), 50'
or
(2) 20' of 6"
(4), 100'
(4), 50'
or
(2) 20' of 6"
(4), 100'
(2 Groups)
(3), 100'
Siamesed
20' of 8"
Rev. #: 4
Date: 7/8/13
1201500

Advertisement

loading