Download Print this page

Sealey DZRE92/C.V2 Manual page 2

10tonne straightener kit with variable tilt

Advertisement

4. asseMblY
4.1.
Assemble the unit using the parts list as your guide. When connecting the hydraulic pump ensure you retain the dust caps for future
use.
4.2.
To use the hydraulic pump, turn the side valve clockwise to close (fig 1). To release the hydraulic pressure, slowly turn the valve anti-
clockwise.
4.3.
beFore First use
Before using the pump for the first time, purge hydraulic circuit in order to eliminate any possible air that may have accumulated during
transit. To do so, connect the pump and ram. Put the pump on a the floor and fully pump out ram. Turn ram upside down open valve,
close ram and pump 8-10 times with the valve open.
5. MaintenanCe
IMPORTANT: Only fully qualified personnel should attempt maintenance or repair
to the hydraulic system.
5.1.
PuMP oil level
5.1.1.
Release pressure and disconnect the ram from the pump.
5.1.2.
Hold pump in an upright position.
5.1.3.
Remove filler plug and add hydraulic oil until it is level with the full mark on the
pump stem.
warning: Do not use brake fluid, or any fluid other than hydraulic jack fluid
as this may cause serious damage to the product and will invalidate the warranty!
Use only Sealey hydraulic oil.
5.2.
general
5.2.1.
Before each use check for broken, cracked, bent, or loose parts, or any visible damage to welds, ram, pump and hose, nuts, bolts, pins,
jaws, clamps, beam, stands, chains, hooks and other fasteners. If any suspect item is found remove from service and take necessary
action to remedy the problem.
5.2.2.
Replace/repair with genuine parts only. Non genuine parts may be dangerous and will invalidate the warranty.
5.2.3.
Keep all parts of the unit clean, oil wheels every three months.
IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE PUMP.
Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK.
DO NOT RETURN PUMP TO US. Please telephone us on 01284 757500 to obtain the address and phone number of your local agent.
If product is under guarantee please contact your dealer.
De-commissioning hydraulic Pump
Should the pump become completely unserviceable and require disposal, draw off the oil into an approved container and dispose of the
product and the oil according to local regulations.
.
environMent ProteCtion
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: No Liability is accepted for incorrect use of this product.
warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey group, kempson way, suffolk business Park, bury st edmunds, suffolk. iP32 7ar
01284 757500
© Jack Sealey Limited
01284 703534
sales@sealey.co.uk
Original Language Version
fig.1
www.sealey.co.uk
DZRE92/C.V2 | Issue:3 (2) 29/10/19

Advertisement

loading

This manual is also suitable for:

5024209242325