Advertisement

Quick Links

User guide
Powerful "Active RFID gateway" for your Ethernet local network
Compact and robust aluminium housing dedicated for the industrial applications
Integrated PoE feature for the SCIEL READER IP2
Multiples IP protocols supported for the network management with your LAN network
SCIEL READER IP2
Ref. SCIBT68B
Specifications could be modified without any notification. Non-contractual document.
www.elainnovation.com
Copyright © 2018 ELA Innovation
1/18
User Guide SCIEL
READER IP2 04B.docx

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCIEL READER IP2 and is the answer not in the manual?

Questions and answers

Summary of Contents for ELA SCIEL READER IP2

  • Page 1 Powerful “Active RFID gateway” for your Ethernet local network Compact and robust aluminium housing dedicated for the industrial applications Integrated PoE feature for the SCIEL READER IP2 Multiples IP protocols supported for the network management with your LAN network 1/18 Specifications could be modified without any notification.
  • Page 2: Table Of Contents

    CONFIGURATION COMMAND LIST ..................16 MECHANICAL SPECIFICATIONS ..................17 2D DRAWINGS ........................17 REFERENCES AND VERSIONS ..................18 STANDARDS ........................18 2/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 3: Main Specifications

    Mini straight RFID 433MHz antenna included Accessories Male Power Supply removable connector included DIN RAIL mounting clip – DIN CLIP01 (not included) 3/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 4: Packing Information

    PACKING INFORMATION The packaging of the SCIEL READER IP2, reference SCIBT68, contains: The SCIEL READER IP2 itself, packed in a ESD plastic bag Its 1.5m RJ45 Ethernet cable A 433MHz RFID mini antenna A SMA-male to BNC-female adapter Figure 1: The SCIEL READER IP2's packaging...
  • Page 5: Physical Information

    7. Mount the main board back and close the housing. Be careful not to tighten the screws too hard, it could make damages. 5/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 6: Pins Terminal Block Wiring

    In this case, if DC power is removed, the reader will NOT be supplied until POE restarts. Figure 6: Reader mounted on a DIN rail with POE supply Figure 7: POE wiring 6/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 7: Led Indicators

    Reader is connected to an active network Permanently lighting Network speed = 10Mpbs Green Network speed = 100Mbps Permanently lighting Yellow Network communication Permanent/Blinking 7/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 8: Reset Button

    Image 10: 4 screws to be unscrewed DIN rail mounting The SCIEL Reader IP2 can be mounted on a standard DIN rail. To do this, you need our DIN CLIP 01 accessory, a screwdriver and a 3mm hex key. Open the reader’s housing by unscrewing the 4 screws on the top (see image above).
  • Page 9: Reader's Operating Mode

    The reader’s blue LED must be on too: that means the network is working. These two LEDs are surrounded by a red rectangle in the image above. 9/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 10: Software Setup

    Setup the Lantronix Ethernet module Figure 15: Main page – Device Installer Open Device Installer, then click the Search button. It will search for every Lantronix device on your network: the SCIEL READER IP2 is interfaced with a Lantronix module. 10/18 Specifications could be modified without any notification.
  • Page 11 Select the Web Configuration tab (surrounded with red). Figure 18: Lantronix configuration page Click the Navigate to button (surrounded with red). 11/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 12 Unless you have very specific needs, you will only use two tabs: Network and Serial Settings, both surrounded with red. 12/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 13 Network tab Figure 21: Network page With the SCIEL READER IP2, the only mode available is Wired Only, so you can’t change it. The main feature of this page is the choice between automatic and fixed IP address. If you want to use a fixed IP, just tick the Use the following IP configuration box (surrounded with red) and fill the fields below it.
  • Page 14 In this case, the backup action is to reset the Ethernet module. To do it, please refer to the chapter 3.5. To apply the new settings, click OK, then Apply Settings and wait for it to finish. 14/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 15: Setup And Test The Reader With Eter

    4.2.2 Setup and test the reader with ETER ETER is an abbreviation for ELA Terminal. It’s designed to communicate with ELA’s readers using serial protocols. Figure 24: ETER v3.0.1 In the black rectangle, you can enter the commands to send to the reader. They will only be sent if the communication port is open.
  • Page 16: Configuration Command List

    Configuration Command List For a complete list of the ELA’s commands, refer to our Software Datasheet MCHD: Reader Communication & setup protocol, available on our website : Reader communication protocol - Software Datasheet All commands have the same syntax: [AABBCC] •...
  • Page 17: Mechanical Specifications

    MECHANICAL SPECIFICATIONS 2D drawings Front View Top View 17/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 18: References And Versions

    EN 301 489 – 3 : 2002 V1.4.1 ; EN 300 220 – 2007 : V2.1.2 CE Mark RoHS Certified 18/18 Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...
  • Page 19 Change on table page 3: Supported IP protocols (network admin) 10/09/18 DRAFT CORRECTION FINAL STATUS CONFIDENTIAL LIMITED GENERAL DISTRIBUTION LEVEL Specifications could be modified without any notification. Non-contractual document. www.elainnovation.com Copyright © 2018 ELA Innovation User Guide SCIEL READER IP2 04B.docx...