24VDC Cabinet Power Supply and does not require AC Line. 1.3 GENERAL CHARACTERISTICS Each channel of the Model 242L provides input hysterisis and digital filtering to qualify the input signal. An input signal must meet the minimum pulse requirements specified in section 1.7.5 in order to produce a valid output.
The sensor circuitry can be broken down into seven major blocks. Each “Input Circuit” block contains the electrical transient devices and the input biasing circuit. Although the Model 242L has two DC inputs, a single digital processing section is used to process both inputs.
The Model 242L requires no adjustments or preventive maintenance. 1.6.1 TROUBLE ANALYSIS The following list should be used to trouble-shoot the Model 242L installation. If the Model 242L unit itself is suspect, see Section 1.6.2 for a complete internal testing sequence.
Model 242L Operations Manual a. Input voltage or pulse width does not meet the requirements of section 1.7.4 or 1.7.5. Verify that the DC input voltage level is less than the DC Inputs True specification. Verify that the DC input pulse width is greater than the Input Pulse Width Accept specification.
Model 242L Operations Manual False (high) ....................greater than 12 Vdc Optically Isolated Solid State Outputs True (low, 50 mA) ....................less than 1.5 Vdc False (high) ....................greater than 16 Vdc Maximum Leakage Current (high) ................. less than 1 uA Maximum Current .......................