Summary of Contents for KYOKUTOH AB2 Series
Page 1
First Edition 2020.09.23 Air Blow Unit(AB2-**) Instruction Manual Please read this instruction manual carefully before operating this unit and use our product correctly. After reading this instruction manual, be sure to keep it in a place where a person who uses or manages the equipment can check it at any time.
1. Safety Precautions ■Introduction The Air Blow Unit (AB2) is a tool for our Dressers to prevent chips being stuck while dressing cap tips. This is a product exclusively for preventing chips being stuck. Do not use for any other purpose. Do not use for Changers other than the specified models. We do not assume any responsibility for malfunctions, repairs, accidents, or others which occurred by using with un-specified models or by other purpose.
2. Parts List ■Example for CDK-R Name Model Note Air Blow Nozzle Holder Block AB2-BLOW-BL-03-001 Air Blow Nozzle AB2-BLOW-NZ-01-003-S Air Blow Bracket for K-Model AB2-BLOW-K-BR-01-001 For CDK-R Samini Compressed Spring 12-1021 CKD Solenoid Valve AB2-01-3-A-DC24V PISCO Fitting PL6-01 Tighten with ②. Tightening PISCO Fitting PL6-M5...
3. Assembly Procedure *Image below is an example of installing to CDK-R. ■Precautions 1. Make sure that the air flow is following the arrow direction. Air OUT Arrow is marked on the back side。 Air IN 2. Check the air pressure. (range: 0.3 ~ 0.5 MPa) 3.
Page 6
■Procedure 1. Remove the screws from the Dresser, then attach the bracket with screws enclosed. (M5*25 Hex Socket Cap Screw, M5 Spring Washer, M5Flat Washer is used. Tightening torque 4.5N/m) *This product is available to both left and right side by flipping the bracket. Be careful of the orientation when attaching.
Page 7
3. Attach the Solenoid Valve. (Use M5*10 M5*10 3-sems. Tightening torque 4.5N/m) 4. Attach the Spatter Tube.
4. Maintenance Changing Cutter / Holder can be done without removing the Air Blow Unit. Squeeze the Nozzle when changing the Cutter / Holder as the image below. 5. Order Model Model Correspond Dresser Note AB2-K CDK-R AB2-KSG CDK-SG AB2-BA CDK-BAYO AB2-SV CD-SVR...
Contact Contact us if there is any damage or machine defects in our products. KYOKUTOH CO., LTD. 181-1, Nakayashiki, Orido-cho, Nisshin, Aichi 470-0115 Japan TEL +81-561-72-8811 FAX +81-561-72-8821 E-Mail: sales@kyokutoh.com http://www.kyokutoh.com KANTO SALES OFFICE TEL +81-49-277-4324 FAX +81-49-277-4325 HIROSHIMA SALES OFFICE TEL +81-82-569-6227 FAX +81-82-569-6228 CHANGER &...