Advertisement

Quick Links

01/2010
Mod:TPG3-15
Production code:TP15/JG

Advertisement

Table of Contents
loading

Summary of Contents for Diamond TPG3-15

  • Page 1 01/2010 Mod:TPG3-15 Production code:TP15/JG...
  • Page 2: Installation

    INSTALLATION Before installation and operation of the appliance, the following must be observed. For EU und CH (Switzerland) applies: The appliance must be connected and operated according to national regulations. This applies for installation, air circulation of the room and exhaustion of combustion products. Only for CH (Switzerland) applies: SVGW norms for gas G1 (2002): Installations for gas EKAS directories no.
  • Page 3: Type Of Construction

    Technical Data (valid only for DE / CH / AT) The appliance is suitable for operation of earth- or liquid gas Category II 2 ELL 3 B/P (DE) II 2 H 3 B/P (AT/CH) allowed connection call pressure pressure Ranges Earth gas 20,0 mbar 18,0 - 25,0 mbar...
  • Page 4 2.3 Heat load, gas connection values, combustion requirement, exhaust quantity Heat loader Gas connection value Earth gas E Earth gas L Liquid gas Combustion Exhaust Type Minor Earth gas H Earth gas LL requirement quantity Full fire fire (G20) (G 25) (G 30/G 31) HuB 9,45 kWh/m HuB 8,12 kWh/m...
  • Page 5: Operation

    Instruction of Users The user must be instructed how to operate the appliance. The instruction for use must be kept to the user. The user must be told that after construction changes in the room, which affects the combustion supply, the operation control must be carried out.
  • Page 6 Cleaning The cleaning should be carried out after each use of the appliance. Before cleaning all armatures must be placed in position -O-. The main gas cock is to be closed. Clean with warm water, if required some detergent, non aggressive cleaner. A strongly dirty plate can be pre cleaned with a scraper.
  • Page 7 Spare parts list for JUMBO GRIDDLEPLATE Types: TP-JG …/G Spare parts list types TP-JG ... / G NO° . DESCRIPTION TP-JG 15 / G TP-JG 12 / G TP-JG 18 / G Burner GS 3648 Injector Ø 1,0 (Propangas 50mbar) GS 3835 Injector Ø...
  • Page 9 Spare parts list TEPPAN YAKI GAS Types: TP …/G TP 12 / G NO° DESCRIPTION TP 15 / G TP 18 / G Burner set NS 9001 GS 8020 S Burner head NS 9001 GS 4030 Burner base NS 9001 GS 4023 Plug 3/8“...
  • Page 10: Troubleshooting

    TROUBLE SHOOTING N° TROUBLE CAUSE CHECK / REPAIR - The cable of igniter is disconnected - Check and repair The igniter does not function - The igniter is damaged - Change (call a technician) The pilot burner does not light - Gas runs out - The gas line to pilot burner is closed - Check and fill gas...
  • Page 11: Gas Conversion

    Gas conversion The gas conversion may only be carried out by a qualified service engineer authorized by the producer. Before conversion, you have to know the gas conditions ( type, gas pressure). 9.1 Technical DATA (valid only for DE / CH / AT) The applience is for operation of earth- or liquid gas Category: II 2 ELL 3 B/P (für DE)
  • Page 12 9.3. Heat load, Gas connection values Obtain the heat load. The appliance is operated in full combustion with fixed nozzles without prior adjustment. For the main burner and pilot flame, small combustion for liquid gas is obtained with fixed nozzle, for earth gas the nozzle has to be regulated.
  • Page 13 9.5.1. Nozzle change type TP ... /G Lift frying plate. Remove fixing screw (1). Lift burner (2) abt. 10 mm and pull away from the mixing chamber (3). Remove then the complete mixing chamber (3) by turning same anti- clockwise from the nozzle. Turn the pressure ring (4) from the nozzle. Pay attention that the built in pressure ring is not lost.
  • Page 14: Pilot Flame Adjustment

    11. Pilot flame adjustment The Pilot flame must be regulated for earthgas. This is done as follows: Pilot flame ignite covering screw (10) with washer (11). Remove with small screw driver, nozzle (C) adjust that main burner ignites well. Turn Uclockwise reduce gas flow, anti clockwise increases gas quantity.
  • Page 15 TROUBLE SHOOTING N° TROUBLE CAUSE CHECK / REPAIR - The cable of igniter is disconnected - Check and repair The igniter does not function - The igniter is damaged - change (call a technician) The pilot burner does not light - Gas runs out - The gas line to pilot burner is closed - Check and fill gas...

Table of Contents