Document No. : ND00338-R06
2. Specifications
Table 2 shows the specifications of the power supplies.
Power supply model
Applicable the model of pumps
Ambient
Pollution degree
Input
Rating Power
Output
Brake method
Brake operation time
Weight
Max. EARTH/GROUND leakage
current
IP Rating
Withstand Voltage
1) Set the input voltage switch of the rear panel of the power supply according to the input
voltage.
2) Value of normal operation
3) Don't perform the withstand voltage test. When testing, the inner parts must remove.
! CAUTION
DO NOT perform the withstand voltage test.
Table 2. Specifications of the power supplies
TC163H
TH162
TH163
Temperature
Humidity
Phase
1)
Voltage
Frequency
Max Power
490[VA]
210[VA]
Over voltage
category
Phase
2)
45[V]
Voltage
2)
800[Hz]
Frequency
4[min]
3)
Viso. INPUT(supply)-EARTH/GROUND
Viso. INPUT(supply)-REMOTE(interface)
Viso. INPUT(supply)-SERIAL(interface)
TC203
TC223
TG200
TG203
TG220F
TS50
‐5 - 40℃
35 - 85%
2
Single
AC90 - 110 or AC180 - 253[V]
50/60[Hz]±2[%]
610[VA]
590[VA]
210[VA]
96[VA]
Ⅱ
3 phases
60[V]
60[V]
800[Hz]
800[Hz]
DC constant current
7[min]
4[min]
Approx. 2.7[kg]
3.5[mA]
IP20 (Service area or operation area)
7
OSAKA VACUUM, LTD.
TC353
TC523H
TG350F
TH520
TG450F
TH522
TG1100F
610[VA]
590[VA]
92[VA]
210[VA]
60[V]
60[V]
750[Hz]
400[Hz]
9[min]
14[min]
1.5[kV]
2.3[kV] (SELV)
2.3[kV] (SELV)
TC1104
TG800F
610[VA]
86[VA]
60[V]
560[Hz]
30[min]
Need help?