Operating Parameters Configuration - Prevail-Catv WT-1550-EM20 Series Operating Manual

1550nm external modulated optical transmitter
Table of Contents

Advertisement

Press the "OK" button shows the configuration page of serial port. As follows:
Change the serial port configuration to 38400-baud rate, 8 data bits, no parity bit, 1 stop bit, no data flow
control, press the "OK" button, you have set up the Windows serial port Hyper Terminal.
You can click "filesave" menu to save this configuration of Hyper Terminal for later using.

5.3 Operating Parameters Configuration

Under the condition of power off, use the serial port lines to connect the RS232 port with the computer port.
Open the Windows Hyper Terminal which you have set up. Then turn on the power, you will see the page
as follows. Enter the password to enter the configuration interface.
Enter the password, display the following screen:
Rev1.1