Do you have a question about the R100 Series and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Wise R100 Series
Page 1
USER MANUAL PRODUCT NAME : TEMPERATURE SENSOR MODEL : R100, R200, R300, R400, R600, R700, R900 SERIES...
Page 2
Instructions for proper and safe operation For the right use and safety of this product, please read through this manual prior to use. Handling error may cause device trip, injury, or disaster. WARNING 1. For the safety, fixing work shall be done by the authorized with instrument or electrical 2.
Ui = 30V , Ii = 100mA Pi = see the instruction manual Ci = 0.1nF, Li = 0.01mH Tag No. 199.Sanggal-dong,Giheung-gu,Youngin-si,Gyeonggi-do,Korea WISE CONTROL INC. 1. Type 4. Tag No. 2. Explosionproof Grade and Allowable Temp 5. Warning Text 3. Explosionproof Certificate No.
A user should select the temperature sensor or thermowell by considering the possible various safety conditions when mounting for the corrosive, abrasive fluids or fluids with the flow rate and pressure. WISE may support the user’s selection but is not responsible for such selection.
If you need to perform maintanance activities, maintanance may only be performed by skilled personnel, and WISE CONTROL can assist in maintenance. 7. 2 Repair Repairs must only carried out by WISE CONTROL or parts manufacturer 7. 3 Calibration We recommend that you regularly recalibrate temperature sensor.
9.3 Function The process temperature shall be measured by the temperature sensor, R1 or R2. Please choose one according to the temperature condition, High, Middle, or Low. The temperature measuring element is a temperature sensor under EN60584 (thermocouple) or EN60751 (thermoresistor) Standard. The temperature sensor may be manufactured either with or without the transmitter.
Page 9
10.2.2 Explosionproof Head 10.2.3 Relation between Connection Length (㎜) and Head Temp. 800℃ 620℃ 430℃ 250℃...
11. Protection Tube 11.1 Generals The protection tube is designed to protect the temperature sensor from tube velocity, pressure, or corrosion and prevent tube fluid from being spilled to the outside during sensor exchange. The protection tube shall be selected by the user (customer) according to the process. Of course, we can give you advice to help your selection but we are not liable for it.
12. Temperature Sensor (Protection Tube) Installation Position 12.1 Attachment 1. The tube temperature sensor shall be installed as follows for anti-sweating. ( EX ) SInstallable Position Upper Part Horizontal Attachment Lower Part Tube Uninstallable Position X 2. The subject fluid shall be stored at a place available for temperature detection. 3.
Page 13
Right Angle Taper b) To Straight Tube Taper Right Angle c) To T Confluent Tube Taper Right Angle...
Page 14
d) To Decreasing Tube Right Angle Taper e) To Other Device Taper Right Angle f) To Header * Use inserting length less than 300㎜.
Inserting Length vs. Velocity and Attachment Condition Length for Right Angle or Length for Flow Velocity Taper Direction < 4㎧ 150 ~ 200㎜ 150 ~ 300㎜ < 2.5㎧ 150 ~ 300㎜ 150 ~ 400㎜ < 0.3㎧ 150 ~ 2000㎜ 13. Connection 13.1 Extension Wire and Cable 1) The extension wire shall have the same specification with the thermocouple sensor.
Page 16
13.3 Temperature Sensor Terminal Connection 13.3.1 thermoresistor General SINGLE(3-WIRE DOUBLE(6-WIRE Explosionpro DOUBLE(6-WIRE SINGLE(3-WIRE 13.3.2 Thermocouple General Head SINGLE(2-WIRE DOUBLE(4-WIRE...