Brief Description
MiniMEP Recording Systems (dataloggers) are designed for
paperless longtime data recording of temperature values and
(dep. on type) relative humidity. Thus the user is able to get a
proof about the course of temperatures and humidity in
corresponding rooms, without application of additional
components as e.g. mechanical printers or PC's.
It is ideal for compliance with 21 CFR process control for food
storage regulations and HACCP Quality Assurance Systems.
The wide temperature range qualifies a MiniMep for both freezing
applications and 'hot' industrial processes.
The Recording System MiniMEP meets all requirements of
the EU Standard EN 12830.
Functions
Records the values of temperature sensors resp. humidity
transmitters for up to 20 years !
Adjustable storage interval.
Example 1: 781 days with a 5 minute interval.
Example 2: > 6 years with a 15 min. interval
Data storage is unlimited even without mains voltage
Real time clock with typ. 10 years battery backup
Continuous recording by external lead accu possible *
Alarm too high/low with time delay for each input
Monitored sensor inputs
Error message memory shows the last 6 occured errors
Clear assignment of measuring position, time and value
plain text designation in the display
Networkable via interface
LCD dot matrix display, backlighted, 4 languages
Display shows actual temperature, time and date
Lets you view all recorded values any time
Easy operating by 3 keys
Digital inputs e.g. for door-contact or other messages *
Isolated alarm relay and built-in buzzer *
Four display languages selectable:
german, english, french, dutch
* (not type 404 S, 2404S)
Temperature- & Humidity Recording System
Technical Manual
MiniMEP
Nr. 5310965-00/20 E
02.07.96
Room 1
Please note Operating and
Safety Instructions on page 12 !
12:30
-23.5°C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MiniMEP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ELREHA MiniMEP Series

  • Page 1 Technical Manual Temperature- & Humidity Recording System MiniMEP Nr. 5310965-00/20 E Valid for the following types containing Software Version 2.5x: MiniMEP 404 S, 2404 S MiniMEP 424 A, 2424 A, 424A/12V MiniMEP 434 A, 2434 A MiniMEP 524 A, 2524 A MiniMEP 534 A, 2534 A Brief Description MiniMEP Recording Systems (dataloggers) are designed for...
  • Page 2: Table Of Contents

    page 2 Technical Manual MiniMEP Data Loggers Note Contents The temperature recording system MiniMEP corresponds to page the requirements of the european standard EN 12830. General Description ..........2 Please note that according to the standard EN 13486, the Operating ............. 3 end-user is bound to a continuous check of the units for Programming Access Authorization, operation and accuracy.
  • Page 3: Operating

    Technical Manual MiniMEP Data Loggers page 3 Operating Organisation of the display pages Pages All parameters and values are partitioned on four push for longer Overview than 1 second sensor pages and a parameter page. The sensor pages contain the recorded values. The parameter page contains setpoints, times, error messages, 01.07.96 15:00...
  • Page 4: Error Messages / -Codes

    page 4 Technical Manual MiniMEP Data Loggers Functions Error memory Different languages The last 6 occured errors will be stored with error code, name, date and time With parameter 'Sprache/language' you can switch the display language to and can be read on the parameter page (last error 1 - last error 6). german, english, french or dutch.
  • Page 5: Parameter Listing (2)434A, (2)534A

    Technical Manual MiniMEP Data Loggers page 5 Parameter Page MiniMEP (2)434 A/ (2)534 A, Temperature-/Humidity Recording. (Default values are factory set) Parameter name Description Range Default value Your value serial number individual serial number for clear idenfication of the unit software version no.
  • Page 6: Parameter Listing (2)404S, (2)424A, (2)524A

    page 6 Technical Manual MiniMEP Data Loggers Parameter Page MiniMEP (2)404S, (2)424A, 424/12V, (2)524A (Default values are factory set) Parameter name Description Range Default value Your value serial number individual serial number for clear idenfication of the unit software version no. of the software + additional info Add.
  • Page 7: Connection, Versions 4Xx

    7 Wiring MiniMEP (2)404S, (2)424A Wiring MiniMEP 424/12V MiniMEP MiniMEP ELREHA ELREHA 10 12 14 16 18 20 22 24 10 12 14 16 18 20 22 24 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9...
  • Page 8 8 Technical Manual MiniMEP Data Loggers Wiring MiniMEP (2)434 A MiniMEP ELREHA don't remove external resistors !! 10 12 14 16 18 20 22 24 1 2 3 4 5 6 7 8 9 11 13 15 17 19 21 23 25...
  • Page 9: Connection, Versions 5Xx

    These ports also Terminals 28 and 29 are only valid for connected to the screw type 524 A. ELREHA terminals 18-20. * Standard types (without "A") don't 7 8 9 10 11 12 13 14 15 16 17 18 19...
  • Page 10: Dimensons

    10 Technical Manual MiniMEP Data Loggers Dimensions of MiniMEP 4xx types 160 (6.3) 130 (5.12) 105 (4.13) MiniMEP ELREHA 60 (2.36) Dimensions/Terminals of MiniMEP (2)524 A, (2)534 A Operating Unit 72,5 MiniMEP RS232 Verbindungen zum Netzteil ELREHA Dimensions/Terminals of MiniMEP (2)524 A, (2)534 A Power Unit...
  • Page 11: Processing Of Data, Pc Connection, Unlock Of Recording System

    Technical Manual MiniMEP Data Loggers page 11 Processing of recorded data / Unlock unit for use with PC-Software The values recorded by the MiniMEP can be retrieved via its PC-Software interfaces and processed by PC-Software. Here are the most If the MiniMEP is connected to controller network, the software important szenarios in practise: "COOLVision"...
  • Page 12: Installation

    page 12 Technical Manual MiniMEP Data Loggers Sensor - Installation CONNECTION & SAFETY INFORMATION Temperature Sensors The guarantee will lapse in case of damage caused by failure With the three offered sensor types TF 501 5M, TF 501 10M and to comply with these operating instructions! We shall not be TF 501 15M the MiniMEP is able to work within the specified accuracy range.
  • Page 13: Technical Data / Accessories

    Technical Manual MiniMEP Data Loggers page 13 Technical Data Supplied accessories (2)4xx types Unit is suitable for storage (S), ambient conditions (A), This manual accuracy level (1) 1 x Fitting PG 9 1 x Fitting PG 11 Supply voltage ....230V / 50-60Hz 1 x Fitting PG 13,5 US-versions (2)xxx ..
  • Page 14: Ce-Statement Of Conformity

    Directive (73/23/EWG) as amended by (93/68/EWG). This declaration is valid for those products covered by the technical manual which itself is part of the declaration. To meet the requirements, the currently valid versions of the relevant standards have been used. This statement is made from the manufacturer / importer ELREHA Elektronische Regelungen GmbH Werner Roemer, Technical Director D-68766 Hockenheim, Germany www.elreha.de...
  • Page 15 Drilling template MiniMEP x422 / x424 Maßstab 1:1 scale 1:1 65mm (2.56) Bohrer/Drill Ø 6mm (.24) 7mm (.27) 116mm (4.57) Bohrer/Drill Ø 6mm (.24)

Table of Contents