IBEX Gast 1HAA Operation & Maintenance Manual

Oil-less piston vacuum pumps & compressors

Advertisement

Quick Links

VACUUM PUMPS & COMPRESSORS
Model 1HAB Shown
Thank you for purchasing this Gast product. It is manufactured to the highest standards
using quality materials. Please follow all recommended maintenance, operational
and safety instructions and you will receive years of trouble free service.
IMPORTANT: PLEASE READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE.
Product Use Criteria:
• Pump only clean, dry air.
• Operate at 32ºF - 104ºF (0ºC - 40ºC).
• Protect unit from dirt & moisture.
• Do not pump flammable or explosive gases or
use in an atmosphere that contains such gases.
• Protect all surrounding items from exhaust air. This
exhaust air can become very hot.
• Corrosive gases and particulate material will damage unit.
Water vapor, oil-based contaminants or other liquids must be filtered out.
• Consult your Gast Distributor/Representative before using at high altitudes.
• These pumps are oil-less and require NO lubrication.
The Teflon-filled rings are self-lubricating and require no oil.
• The motor bearings are grease-packed for the lifetime of the bearings.
®Registered Trademark/™Trademark of Gast Manufacturing Inc., Copyright © 2002 Gast Manufacturing Inc. All Rights Reserved.
OIL-LESS PISTON
O
& M
PERATION
Model 3HBB Shown
ISO 9001 & 14001 CERTIFIED
PART NO. 70 - 2100 G441PL (REV-K)
M
AINTENANCE
Model 3HEB Shown
www.gastmfg.com
ANUAL
Model PCD Shown

Advertisement

Table of Contents
loading

Summary of Contents for IBEX Gast 1HAA

  • Page 1 PART NO. 70 - 2100 G441PL (REV-K) OIL-LESS PISTON VACUUM PUMPS & COMPRESSORS & M PERATION AINTENANCE ANUAL Model 1HAB Shown Model 3HBB Shown Model 3HEB Shown Model PCD Shown Thank you for purchasing this Gast product. It is manufactured to the highest standards using quality materials.
  • Page 2 Mounting Your safety and the safety of others This product can be installed in any orientation. is extremely important. Mounting the product to a stable, rigid operation surface and using shock mounts will reduce noise and vibration. We have provided many important safety messages in this manual and on your product.
  • Page 3: Operation

    Model that is permanently wired: Electrical Connection This product must be connected to a grounded, metallic, permanent wiring system, or an equipment WARNING grounding terminal or lead on the product. Power supply wiring must conform to all required safety codes and be installed by a qualified person. Check that supply voltage agrees with that listed on product nameplate.
  • Page 4: Maintenance

    It is your responsibility to operate this product at Check the thickness of the rider ring. It should measure recommended pressures or vacuum duties and greater than .055”. Change all rings if thickness room ambient temperatures. Do not start against a measures .055”...
  • Page 5 Check that all external accessories such as relief SERVICE KIT INSTALLATION valves and gauges are attached to cover and are not damaged before re-operating product. WARNING If pump still does not produce proper vacuum or pressure, send unit to a Gast Authorized Service Facility for repair.
  • Page 6: Parts & Ordering Information

    Air receiver loses pressure: 1. Check for system leaks through pipes, fittings and seals. 2. Inspect the check valve to see if it is allowing air pressure to leak back into unit. 3. Pressure pumps will have bubbles around head assembly during operation.
  • Page 7 EXPLODED PRODUCT VIEW – MODEL 1HAB...
  • Page 8 PARTS & ORDERING INFORMATION Please reference the exploded view on the opposite page for the following model and parts tables. 1VBF – 3LBD SERIES DESCRIPTION 1VBF 1VSF 2LBB 2HBB 2HBC 3HBB 3HBE 3LBA 3LBD INLET FILTER ASSEMBLY B300A B300A B300A B300A B300A B300A...
  • Page 9 EXPLODED PRODUCT VIEW – MODEL 1VBF...
  • Page 10 PARTS & ORDERING INFORMATION Please reference the exploded views on the next page for the following model and parts tables. PAB – VAB SERIES DESCRIPTION FILTER ASSEMBLY B300A B300A 2 ∆ FELT B344A B344A SAFETY VALVE AT517 – CYLINDER HEAD AF508 AF508 5 ∆...
  • Page 11 EXPLODED PRODUCT VIEWS – MODEL PAB (TOP) & MODEL PBB (BOTTOM)
  • Page 12 PARTS & ORDERING INFORMATION Please reference the exploded view on the next page for the following model and parts table. 5VDF – 8LDF SERIES DESCRIPTION 5VDF 5VSF 6LCF ** 6HDK 7LDE 7HDD 7HDE 8HDM 8HDN 8LDF INLET FILTER ASSEMBLY B300F B300F B300F B300A...
  • Page 13 EXPLODED PRODUCT VIEW – MODEL 5VDF...
  • Page 14: Warranty

    WARRANTY Gast finished products, when properly installed and operated under normal conditions of use, are warranted by Gast to be free from defects in material and workmanship for a period of twelve (12) months from the date of purchase from Gast or an authorized Gast Representative or Distributor.
  • Page 15 MAINTENANCE RECORD DATE PROCEDURE PERFORMED...
  • Page 16: Troubleshooting Chart

    PART NO. 70 - 2100 G441PL (REV-K) TROUBLESHOOTING CHART High Pump Motor Excess Reason and remedy Vacuum Pressure Vacuum Pressure Overheat Overload Noise for problem. • • • • Filter dirty. Clean or replace. • At pump • • • Muffler dirty.

Table of Contents