1.

GENERAL

Pressure/vacuum switches are electro mechanical equipments which send an electric or pneumatic signal as a fixed value of pressure (or negative pressure) is reached.
Depending of the using, there are two different types:
1.1 Diaphragm pressure/vacuum switch (
very low pressures.
WARNING! • A pressure/vacuum switch isn't a safety device!
• Fixing, wiring and settings must be performed by qualified staff, and only after a careful reading of this User's Guide.
2.

TECHNICAL DATA

2.1 This User's Guide and Maintenance Reference must be considered an integrating part of the shipment. Always check that the goods received are integral and corresponding
to the order. Compare the inscription printed on the label of the equipment, on the order and on the delivery note, issued by FOX s.r.l.; in case of discordance, don't install the
instrument on the system but contact immediately FOX Srl.
2.2 Before fixing the equipment, compare technical data shown in Tab. 1 to those printed on the label on the device.
Shaping, material and
Hexagons: Ch. 24 (K4-F4-WF4), Ch. 27 (F3), Ch. 32 (K9).
treatment standards:
Trivalent zinking steel. Available in (X) AISI 316L and (L) brass.
min/MAX (°C) working
TS -20÷+80 (K4 - F3 - F3S - K6 - KR6 - K7 - K9 - F5 - K5 - K51 - W3 - WF4)
temperature, TS:
Note: Min. and Max. working temperature are the project installation, or the pressurised circuit temperature.
WORKING
1
Commutation freq. (cycles/min
):
Hysteresys (% setting at 20°C – diaph.):
Hysteresys (% setting at 20°C - piston):
Intervention precision (% at 20°C):
*Operating point:
Signal condition:
MAX Loading Am at Volt-(AC):
MAX Loading Am at Volt-(DC):
Weight (kg):
Mechanical and electrical life:
Installation position:
Pressure switch - K4
Regulation
range (bar)
Type
R
0.2÷2.5
M
S
1÷12
SM
1÷12
M
SP
1÷12
P
T
5÷50
P
TM
5÷50
M
V
10÷100
P
VM
1÷12
M
Z
20÷200
P
Y
50÷400
P
Regulation
range (bar)
Type
F30
0,2÷2,5
F31
1÷10
M
F31M
1÷10
F31P
1÷10
P
F33
5÷50
F35
10÷100
P
F37
30÷250
F39 100÷400
Pressure switch K6-KR6
Regulation
range (bar)
Type
K(R)60 0,2÷2
M
K(R)61
1÷15
K(R)63
4÷40
K(R)6415÷150
P
K(R)6525÷250
Regulation
range (bar)
Type
K93
2÷40
K94
5÷100
K95
20÷200
P
K97
30÷300
K99
40÷400
Regulation
range (bar)
Type
K53
2÷40
K54
5÷100
K55
20÷200
P
K57
30÷300
K59
40÷400
Regulation
range (bar)
Type
W31-0.05÷-0.5
M
W32-0.15÷-0.8
FOX s.r.l. via Romagna, 6 – 20090 Opera (MI) – Italy - tel. +39.02.57.60.00.33 - +39.02.57.60.65.43 – Fax +39.02.57.60.01.76
M
): mechanical type, very sensible, for
K4
F4
F3
90
90
90
~10
~10
~10
~20
~15
~15
±5
±4
±4
3
4
3
4
4
0.5-250
0.5-250
0.5-250
0.25-125
0.25-125
0.25-125
0,06
0,05
0,08
Mechanical life is, for all, 10
For all: position is non relevant, as soon as the technical room for connection fixing/removing is provided
3
*Note on trigger: 3
External screw; 4
MAX
Contact and
Hydraulic
PS
electrical
connection
(bar)
connection
25
A=NO
0=1/8"BSP
150
1=1/4"BSP
300
C=NC
2=1/8"BSPT
300
3=M10x1
F=6.3mm
150
4=1/8"NPT
fast-on end.
300
5=1/4"NPT
O=screwed
150
6=1/4"BSPT
conn.
300
600
Pressure switch F3
MAX
Contact and
Hydraulic
PS
electrical
connection
(bar)
connection
10
25
150
M2=16x16
300
connector
1/4"BSP
M3=30x30
Male
connector
300
600
MAX
Contact and
Hydraulic
PS
electrical
connection
(bar)
connection
25
M3=30x30
conn.
1/4"BSPT
200
M12=M12
Male
conn.
300
Pressure switch K9
MAX
Contact and
Hydraulic
PS
electrical
connection
(bar)
connection
200
300
M3=30x30
1/4"BSP
400
conn.
Male
600
Pressure switch K5
MAX
Contact and
Hydraulic
PS
electrical
connection
(bar)
connection
200
300
M4=conn. by
1/4"BSP
400
light signal
Female
500
600
Vacuum switch W3
MAX
Contact and
Hydraulic
PS
electrical
connection
(bar)
connection
P2=fast-on
endings
M2=16x16
1/4"BSP
10
conn.
Female
M3=30x30
conn.
http://www.fox.it
1.2 Piston pressure switch (
pressures.
Square: 30x30 mm (K6-K7-KR6-F5), 40x40 mm (F3S-K5-K51-W3).
Anodized aluminium. Available in (X) AISI 316L and (L) nickel plated brass.
TS -25÷+85 (F4)
F3S
K6-KR6
K7
90
90
120
~7
~10
~15
-
~15
~15
±3
±4
±3
4
4
5
5
4
5
5
D means setting for lowering pressure; U means setting for rising pressure
0.5-250
0.5-250
5.0-250
0.25-125
0.25-125
0.25-250
0,10
0,20
0,20
6
cycles at 70 bar (1000 psi), at 20 °C
4
5
Internal screw; 5
Internal screw, protected by a safety cap; 6
Body material
X=AISI 316L
L=Brass
B=Nickel plated
brass
-
If missing,
means zinc-
plated carbon
steel
Body material
X=AISI 316L
L=Brass
-
If missing,
means zinc-
plated carbon
steel
Body material
B=Nickel plated
brass
Body material
zinc-plated
carbon steel
Body material
40x40mm
Anodized
aluminium
Body material
X=AISI 316L
40x40mm
Anodized
aluminium
e-mail:fox@fox.it
P
): mechanical type, less sensitive but fit for higher
K9
F5
K5
120
120
120
-
-
-
~15
~15
~15
±2
±3
±2
6
5
3
7
6
5
3
(P 7
)
5.0-250
5.0-250
5.0-250
0.25-250
0.1-250
0.25-250
0,40
0,15
0,35
Electrical life is, for all, inversely proportional to the contacts loading.
6
External gear; 7
Pressure switch F4
Regulation
MAX
Contact and
range (bar)
Type
PS
electrical
(bar)
connection
R
0,2÷2,5
25
M
S
1÷12
SM
1÷12
150
P3=6,3x0,8
SP
1÷12
P
300
Fast-on
T
5÷50
P
300
M2=16x16
connector
TM
5÷50
M
150
M3=30x30
V
10÷100
P
300
connector
VM
1÷12
M
150
Z
20÷200
300
P
Y
50÷400
600
Pressure switch F3S
Regulation
MAX
Contact and
range (bar)
Type
PS
electrical
(bar)
connection
F3S1 0.05÷0.5
M2=16x16
F3S2
0.1÷1
connector
M
15
M3=30x30
F3S3
0.5÷5
connector
F3S4
1÷10
Pressure switch K7
Regulation
MAX
Contact and
range (bar)
Type
PS
electrical
(bar)
connection
K71
1÷12
M
25
M4=conn. by
K73
5÷50
300
light signal
K75
15÷150
350
-
P
If missing,
K77
30÷300
400
STD conn.
Pressure switch F5
Regulation
MAX
Contact and
range (bar)
Type
PS
electrical
(bar)
connection
F53
5÷50
300
M3=30x30
P
F55
15÷150
350
conn.
F57
30÷300
400
Pressure switch K51
Regulation
MAX
Contact and
range (bar)
Type
PS
electrical
(bar)
connection
K51.1
0.2÷2
12
M4=conn. by
K51.2
0.5÷5
light signal
K51.3
1÷10
M
15
-
If missing,
K51.4
3÷15
20
STD conn.
Vacuum switch WF4
Regulation
MAX
Contact and
range (bar)
Type
PS
electrical
(bar)
connection
M2=16x16
conn.
WF4 -01÷-0.8
M
10
M3=30x30
conn.
Date:
10/11/17
Rev.2
Language:
ENGLISH
Compiled:
M. G.
Tab.1
K51
W3
WF4
120
90
60
~10
~15
~20
-
-
-
±2
±7
±15
3
7
4
4
3
(P 7
)
4
4
5.0-250
3.0-125
3.0-125
0.25-250
0.25-125
0.25-125
0,35
0,10
0,055
7
Knob
Hydraulic
Body material
connection
X=AISI 316L
0=1/8"BSP
L=Brass
1=1/4"BSP
B=Nickel plated
2=1/8"BSPT
brass
3=M10x1
-
If missing,
4=1/8"NPT
means zinc-
5=1/4"NPT
plated carbon
6=1/4"BSPT
steel
Hydraulic
Body material
connection
X=AISI 316L
P=PVC
-
1/4"BSP
If missing,
Female
means
anodized
aluminium
Hydraulic
Body material
connection
X=AISI 316L
-
If missing,
1/4"BSP
means zinc-
Male
plated carbon
steel
Hydraulic
Body material
connection
30x30mm
1/4"BSP
Anodized
Female
aluminium
Hydraulic
Body material
connection
X=AISI 316L
1=1/4"BSP
40x40mm
Female
Anodized
aluminium
Hydraulic
Body material
connection
X=AISI 316L
1=1/4"BSP
L=Brass
Female
-
If missing,
2=1/8"BSPT
means zinc-
Female
plated carbon
3=M10x1
steel
Page 1 of 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fox K4

  • Page 1 2.1 This User’s Guide and Maintenance Reference must be considered an integrating part of the shipment. Always check that the goods received are integral and corresponding to the order. Compare the inscription printed on the label of the equipment, on the order and on the delivery note, issued by FOX s.r.l.; in case of discordance, don’t install the instrument on the system but contact immediately FOX Srl.
  • Page 2 Min and max limits of temperature are shown in Tab.1 as min/MAX (°C) working temperature, TS. The temperature supported by elastomer will always be equal or higher than the equipment one. For detailed information on chemical compatibility between fluids and elastomers, write to Manufacturer, FOX s.r.l. communicating the exact symbol of the fluid in use and the working temperature.

This manual is also suitable for:

F4F3F3sK6Kr6K7 ... Show all

Table of Contents