Xtreme Power 65038 Owner's Manual And Safety Instructions

Xtreme Power 65038 Owner's Manual And Safety Instructions

4000w generator

Advertisement

4000W GENERATOR
ITEM: 65038 & 65038-1
OWNER'S MANUAL AND SAFETY INSTRUCTIONS
SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY,
OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT'S
SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH
AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER)
FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT: 909.628.0880 MON-FRI 9AM TO 3PM PST

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 65038 and is the answer not in the manual?

Questions and answers

Summary of Contents for Xtreme Power 65038

  • Page 1 4000W GENERATOR ITEM: 65038 & 65038-1 OWNER’S MANUAL AND SAFETY INSTRUCTIONS SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY, OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER) FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT: 909.628.0880 MON-FRI 9AM TO 3PM PST...
  • Page 2: Important Safety Information

    IMPORTANT SAFETY INFORMATION GENERAL SAFETY WARNINGS Read all safety warnings and instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur.
  • Page 3 IMPORTANT SAFETY INFORMATION People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to a heart pacemaker could cause pacemaker interference or pacemaker failure. Caution is necessary when near the generator’s magneto or recoil starter. Use only accessories that are recommended by XtremePowerUS for your model. Accessories that may be suitable for one piece of equipment may become hazardous when used on another piece of equipment.
  • Page 4 IMPORTANT SAFETY INFORMATION DO NOT smoke, or allow sparks, flames, or other sources of ignition around the equipment, especially when refuelling. Before use, check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the equipment’s operation. If damaged, have the equipment serviced before using. Many accidents are caused by poorly maintained equipment.
  • Page 5: Generator Precautions

    IMPORTANT SAFETY INFORMATION 1. Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. 2. If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance, or if the rated load capacity of the generator has been exceeded.
  • Page 6: Parts And Components

    PARTS AND COMPONENTS...
  • Page 7: Pre-Operation Inspection

    OPERATION PRE-OPERATION INSPECTION Generator OIL: a key factor in deciding the generator’s performance. Do not apply generator oil with additives or 2-stroke gasoline oil, as they haven’t enough lubrication, which may shorten the generator’s service life. 1. Before adding fuel, make sure the generator is on a level, flat surface equipment. Generator oil recommended: SAE10W-30.
  • Page 8: Starting The Generator

    OPERATION STARTING THE GENERATOR 1. Push the fuel switch to “ON”. 2. Push the chock lever to “OFF”. 3. Move left the throttle lever a little. 4. Start the generator. ROPE HANDLE STARTER: Push the generator switch to “ON”. Pull slightly the starting rope handle up until feeling anti-action, and then make a rapid pull.
  • Page 9: Stopping The Generator

    OPERATION Generator Oil Alarm: The generator oil alarm is designed to alarm the user the fact that the generator oil in the crankcase in insufficient. Run with insufficient generator oil may damage the generator. Once oil level in the crankcase is too low, the generator oil alarm will stall the generator automatically to make it free of damage while the generator switch is still at “ON”.
  • Page 10: Wiring Diagram

    SPECIFICATIONS WIRING DIAGRAM 1.3GF 2GF 1.3-2GF, 1.3GF-3, 1.5GF-3 2GF-2, 2GF-3, 2.5GF-3...
  • Page 11: Maintenance Schedule

    SPECIFICATIONS MAINTENANCE SCHEDULE Replacement of Generator Oil: A still hot generator is helpful to drain out the generator oil in the crankcase rapidly and entirely. 1. Turn off the oil filler cap and drain plug to drain generator oil thoroughly. Reinstall the drain plug and screw in securely. 2.
  • Page 12: Specifications And Maintenance

    SPECIFICATIONS AND MAINTENANCE TROLLEY ASSEMBLY: 1. Assemble the Wheel Bracket and Rubber on the frame with bolts and nuts.engine. Fix the Axle on the frame with bolts and nuts 2. Fix the left and right Wheels on the frame with splint pin.
  • Page 13: Maintenance

    MAINTENANCE NOTE: Do not dump oil containers or discarded engine oil into rubbish boxes or onto the ground. For the sake of environmental protection, we suggest you take in discarded engine oil with a closed container and bring to local recycling station. SERVICE OF AIR CLEANER: A dirty air cleaner may block enough air’s flowing into the carburetor.
  • Page 14 MAINTENANCE The spark plug must be tightened securely, or it may become very hot to damage the engine. Only use recommended spark plug or the equivalent. Incorrect heat range of the spark plug may damage the engine. The muffler is very hot during running the engine and even a long Time after stopping. Never touch it, or you may get burns.
  • Page 15: Troubleshooting

    TROUBLESHOOTING...
  • Page 16 TROUBLESHOOTING When testing the spark plug, never hold the high- voltage wire of the spark plug with wet hand. Make sure there is no spilled fuel outside the engine and that the spark plug isn’t dipped with fuel. To prevent fire, keep sparks for away from the spark plug mount hole. Once you find any of above problems, contact the authorization entitle to the dealer of the privilege helps for you.
  • Page 17: Crankcase Assembly

    CRANKCASE ASSEMBLY...
  • Page 18: Crankcase Cover Assembly

    CRANKCASE COVER ASSEMBLY...
  • Page 19 CYLINDER HEAH AND HEAD COVER ASSEMBLY...
  • Page 20 CRANKSHAFT, PISTON CONNECTING AND BALANCING SHAFT...
  • Page 21 OMBINATION OF CAM SHAFT AND VALVE ROCKER...
  • Page 22: Carburetor Assembly

    CARBURETOR ASSEMBLY...
  • Page 23 FULL TANK ASSEMBLY...
  • Page 24: Air Cleaner Assembly

    AIR CLEANER ASSEMBLY MUFFLER...
  • Page 25: Recoil Starter

    RECOIL STARTER...
  • Page 26 REGULATING CONTROL SYSTEM ASSEMBLY...
  • Page 27 FLYWHEEL / IGNITION ASSEMBLYY IGNITON COIL...
  • Page 28 STARTING MOTOR ASSMBLY...
  • Page 29: Generator Assembly

    GENERATOR ASSEMBLY...
  • Page 30: Control Panel Assembly

    CONTROL PANEL ASSEMBLY...
  • Page 31: Frame Assembly

    FRAME ASSEMBLY...
  • Page 32 OF NOTE PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT.

This manual is also suitable for:

65038-1

Table of Contents