The NE-SS and NE-SSR are 2-gang vandal proof and weather resistant sub stations designed for use with the NEM,
NDR and NDRM systems. The NE-SS-GP is the gold-plated model. They are constructed of 12 gauge stainless steel and
are equipped with an option for an external output contact closure when the sub station places a call (relay required). The
units either flush mount into a 2-gang box, or surface mount with the SBX-2G (SBX-GP2 for gold subs). Each unit
includes tamper proof screws and a tool for installation. The NE-SSR features a red mushroom call button.
INSTALLATION:
1. For flush mounting, install sub station in standard 2-gang electrical box with min. 2-1/2" depth.
2. For surface mounting, install sub station in the SBX-2G(-GP2) surface mount enclosure.
3. IMPORTANT! These units are designed for use in normal weather conditions, and to allow drainage and
evaporation of moisture that naturally gets into the unit. Do not apply caulking or silicone sealant around the
unit when installing, and do not use weather stripping around the perimeter of the box when mounting. If
sealing the unit is required, the bottom must remain unsealed.Sealing the unit will prevent or inhibit moisture from
dissipating from inside the unit, which may cause corrosion or deterioration to the internal components over time.

WIRING DIAGRAM:

NEM Master
1
2
3
~
20
PS-2420UL
E
+
+
-
-
H
duration of call-in
Page 1
Vandal and Weather Resistant Sub Stations
- INSTRUCTIONS -
MOUNTING:
NE-SS
NE-SSR/SS-GP
TORX
screws
NE-SS/-SSR/-GP
Red
Green
jumper
(Do not cut)
Blk
Blu
Blk
RY-PA
Dry closure
Yel
output for
WIRE DESIGNATIONS:
Red: + side of speaker. Connect to station number on master station.
Blue: Trigger for corridor lamp. 7V DC when call-in signal is activated.
Black:- side of speaker, Common. Connect to E on master station.
Purple:Negative trigger wire for extra relay contact closure at sub during call.
Small wht & blk: Speaker connection to PCB
Small brn (x2): Call button connection to PCB
2-GANG BOX
Do not apply sealant
between unit and box.
NE-SS/-SSR/-GP
(w/dry closure output)
Red
Green
jumper
Blk
Blu
Pur
Blk
NOTES:
1. Do not cut the green jumper on the circuit board
unless a corridor lamp is included at the sub
station.
2. The units flush mount into a 2-gang box.
3. To surface mount the NE-SS or NE-SSR, order
the SBX-2G surface mount box separately. Use
SBX-GP2 for NE-SS-GP.
NE-SS/-SSR/-GP
(w/corridor lamp)
Red
Green
jumper
Blk
Blu
Cut GREEN
jumper
Blu
Blu
NBY-4A

Advertisement

loading

Summary of Contents for Aiphone NE-SS

  • Page 1: Wiring Diagram

    Vandal and Weather Resistant Sub Stations The NE-SS and NE-SSR are 2-gang vandal proof and weather resistant sub stations designed for use with the NEM, NDR and NDRM systems. The NE-SS-GP is the gold-plated model. They are constructed of 12 gauge stainless steel and are equipped with an option for an external output contact closure when the sub station places a call (relay required).